Terrence Jao

Dr. Terrence Jao

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 March 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
VLVanessa Landes
Vanessa Landes
AJAhsan Javed
Ahsan Javed
TJTerrence Jao
Terrence Jao
QQQin Qin
Qin Qin
Krishna NayakKrishna Nayak
Krishna Nayak

27 August 2019 in PLOS ONE
Verified
Journal Article
Open access
PDF file
TJTerrence Jao
Terrence Jao
Krishna NayakKrishna Nayak
Krishna Nayak
To determine the impact of imaging parameters on the temporal signal-to-noise ratio (TSNR) of quantitative cardiac magnetic resonance (MR) in humans, and to determine applicability of the physiological noise covariance (PNC) model for physiological noise (PN). We conducted MRI experiments in four healthy volunteers, and obtained series of short-axis cardiac images acquired with snapshot balanced steady-state free precession (bSSFP) and snapshot gradient echo (GRE) using a broad range of spatial resolutions and parallel imaging acceleration factors commonly used in quantitative cardiac MR. We measured regional SNR and TSNR in these datasets and fit the measurements to the PNC model for PN, which assumes that PN scales with signal strength. The relationship between SNR and TSNR in human cardiac MR without contrast preparation was well modeled by the PNC model. SNR consistently decreased as the spatial resolution (matrix size) and acceleration factor (R) increased for both GRE and bSSFP imaging. TSNR varied linearly with SNR using GRE imaging, when SNR was low (SNR < 20), and approached an asymptotic limit using bSSFP imaging, when SNR was high (SNR > 40). The PNC model can be used to guide the choice of matrix size and acceleration factor to optimize TSNR in stable contrast cardiac MR, such as T2-prepared Blood-Oxygen-Level-Dependent (BOLD) and several variants of Arterial Spin Labeled (ASL) cardiac MR.

18 March 2019 in bioRxiv
Verified
Preprint
Open access
TJTerrence Jao
Terrence Jao
KNKrishna Nayak
Krishna Nayak
Purpose: To determine the impact of imaging parameters on the temporal signal-to-noise ratio (TSNR) of quantitative cardiac magnetic resonance (MR) in humans, and to determine applicability of the physiological noise covariance (PNC) model for physiological noise (PN). Methods: We conducted MRI experiments in four healthy volunteers, and obtained series of short-axis cardiac images acquired with snapshot balanced steady-state free precession (bSSFP) and snapshot gradient echo (GRE) using a broad range of spatial resolutions and parallel imaging acceleration factors commonly used in quantitative cardiac MR. We measured regional SNR and TSNR in these datasets and fit the measurements to the PNC model for PN, which assumes that PN scales with signal strength. Results: The relationship between SNR and TSNR in human cardiac MR without contrast preparation was well modeled by the PNC model. SNR consistently decreased as the spatial resolution (matrix size) and acceleration factor (R) increased for both GRE and bSSFP imaging. TSNR varied linearly with SNR using GRE imaging, when SNR was low (SNR < 20), and approached an asymptotic limit using bSSFP imaging, when SNR was high (SNR > 40). Conclusions: The PNC model can be used to guide the choice of matrix size and acceleration factor to optimize TSNR in stable contrast cardiac MR, such as T2-prepared Blood-Oxygen-Level-Dependent (BOLD) and several variants of Arterial Spin Labeled (ASL) cardiac MR.

30 July 2026 in Bioengineering
Verified
Journal Article
Open access
PDF file
TJTerrence Jao
Terrence Jao
PJPraveen Jayapal
Praveen Jayapal
JVJana Vincent
Jana Vincent
JPJohn Pauly
John Pauly
CSCeara Stack
Ceara Stack
ASAli B. Syed
Ali B. Syed
A high-density posterior cushion coil (HDPCC) can improve the SNR in pediatric MRI by conforming to the body and minimizing distance to the imaged volume when compared to a conventional rigid built-in table coil array. Posterior coil arrays built into MRI tables are mainstays but provide suboptimal performance in pediatric imaging due to their distance from the imaged volume and lower coil density. Our goal is to improve pediatric MRI by constructing a prototype 30-channel high-density posterior cushion coil (HDPCC) incorporated into a padded cushion. Twenty-five pediatric patients were scanned with the HDPCC, and twenty-five pediatric controls served as the comparison group using standard coils. Two radiologists graded image quality on a 5-point scale. SNR was measured in the right paraspinal musculature and the liver. All images obtained with the HDPCC were diagnostic (mean score 4.13/5). SNR in the superficial tissues of the paraspinal musculature was 34% higher with the HDPCC than with standard coils, while SNR in the deeper tissues of the liver was statistically similar between the two coils. HDPCC yields improved the signal-to-noise ratio in phantoms and pediatric study participants by conforming to the body.