Arie Marcovich

Prof. Dr. Arie Marcovich

orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 July 2021 in Cornea
Verified
Journal Article
Open access
GAGerd U. Auffarth
Gerd U. Auffarth
Hyeck-Soo SonHyeck-Soo Son
Hyeck-Soo Son
MKMatthias Koch
Matthias Koch
JWJan Weindler
Jan Weindler
PMPatrick Roman Merz
Patrick Roman Merz
VMVictor Augustin, MD
Victor Augustin, MD
Purpose: The purpose of this study was to describe a novel device that may serve as an alternative to Descemet membrane endothelial keratoplasty (DMEK) for the treatment of chronic corneal edema. Methods: The EndoArt (EyeYon Medical, Israel) is a flexible, 50-μm thin artificial endothelial layer that matches the cornea's posterior curvature and functions as a fluid barrier at the posterior stroma, replacing the diseased endothelium. Similar to a DMEK approach, it is implanted into the anterior chamber, carefully positioned on the posterior stroma, and secured using an air–gas mixture. Two patients with chronic corneal edema resulting from endothelial decompensation underwent implantation of the new artificial lamella. Results: In patient 1, the central corneal thickness (CCT) decreased from 730 μm preoperatively to 593 μm at 1 day postoperatively. In patient 2, the CCT decreased from 761 μm preoperatively to 487 μm at 1 day postoperatively. Both patients reported high satisfaction and an overall brighter visual quality. Although dislocation of the lamella occurred in both cases, the CCT was promptly restored after a repositioning procedure and remained stable at the 17-month follow-up (CCT of 526 and 457 μm for patients 1 and 2, respectively). In contrast to DMEK donor tissue, the artificial lamella is sufficiently robust to allow easy intraocular manipulation without the risk of damaging the implant. It is easily removable and does not require any immunosuppressive treatment because of its nonbiological nature. Conclusions: Implantation of the EndoArt led to rapid corneal deturgescence and CCT restoration, presenting a possible option for patients with chronic corneal edema.

15 December 2018 in BMJ Open Ophthalmology
Verified
Journal Article
Open access
PDF file
AMArie Marcovich
Arie Marcovich
TTTamer Tandogan
Tamer Tandogan
MBMor Bareket
Mor Bareket
EEEva Eting
Eva Eting
IKIfat Kaplan-Ashiri
Ifat Kaplan-Ashiri
Ramin KhoramniaRamin Khoramnia
Ramin Khoramnia
Objective To report 11 cases of intraocular lens (IOL) opacification after pars plana vitrectomy (PPV) involving intravitreal gas injection. Methods and analysis Eleven cases of hydrophilic IOLs that opacified following PPV with intravitreal gas injection are described. Eight IOLs were explanted and analysed by light microscopy and scanning electron microscopy. Staining with alizarin red and von Kossa stains, as well as energy dispersive X-ray spectroscopy (EDX) were performed. Three IOLs were not explanted. The surgeons attached the clinical data. Results The IOLs were hydrophilic acrylic produced by six manufacturers. Six patients underwent primarily phacoemulsification with IOL implantation. PPV with intravitreal gas injection was performed 3 months–6 years afterwards. The other five patients underwent combined phacoemulsification with IOL implantation and PPV with intravitreal gas injection. IOL opacification was recorded 1 month –6 years after PPV. In eight patients, the IOLs were explanted 1 month–9 years after opacification was noticed. In three patients, the opacified IOL was not explanted. IOLs had opacified mainly anteriorly at the pupillary entrance or capsulorhexis opening. Light microscopy demonstrated granular surface deposits on the IOLs that stained positive for calcium by alizarin red and von Kossa stains. EDX analysis of the deposits detected calcium and phosphorus. Conclusions Hydrophilic acrylic IOLs can opacify due to calcium deposition after PPV and intravitreal gas injection and may require IOL explantation. A hydrophobic IOL may be preferred when a simultaneous phacoemulsification and vitrectomy with intravitreal gas is performed.

5 November 2024 in Cornea
Verified
Journal Article
Open access
ODOfer Daphna
Ofer Daphna
GAGerd U. Auffarth
Gerd U. Auffarth
RLRuth Lapid-Gortzak
Ruth Lapid-Gortzak
SCSunita Chaurasia
Sunita Chaurasia
EGEfrat Msc Gilboa
Efrat Msc Gilboa
AMArie Marcovich
Arie Marcovich
Purpose: The purpose of this study was to report the safety and efficacy results of an artificial lamellar implant for the treatment of chronic corneal edema. Methods: The EndoArt (EyeYon Medical, Ness Ziona, Israel), an artificial endothelial replacement membrane designed to treat corneal edema, was implanted in 24 eyes of 24 patients with low-to-normal visual potential. We present the safety and efficacy results from a prospective, open-label, single-arm, multicenter study conducted over a 12-month period. Results: Twenty-four patients were enrolled, with no device-related serious adverse events reported. Seventeen patients completed 12-month follow-up, showing a reduction in average central corneal thickness from 759 ± 116 μm to 613 ± 135 μm. Best-corrected distance visual acuity improved from 1.88 ± 0.79 logarithmic minimum angle of resolution (logMAR) to 1.34 ± 0.57 logMAR. Sixty percent gained at least 3 early treatment diabetic retinopathy study (ETDRS) lines. The EndoArt was removed in 5 cases due to incomplete attachment and replaced by corneal transplants; 1 patient was lost to follow-up, and 1 had a procedure failure. No device-related long-term complications, infections, or inflammations were reported. The implants remained transparent throughout the study. Conclusions: The first-in-human results of EndoArt implantation demonstrated the device's potential to treat patients suffering from corneal edema with a favorable safety profile and effective edema reduction in most subjects, with no device-related serious adverse event. The EndoArt may offer a viable solution in regions facing a shortage of donor corneas, as well as for patients who have poor prognosis with human tissue.

1 August 2017 in Investigative Ophthalmology & Visual Science
Verified
Journal Article
Open access
PDF file
JBJurriaan Brekelmans
Jurriaan Brekelmans
AGAlexandra Goz
Alexandra Goz
MDMor M. Dickman
Mor M. Dickman
ABAlexander Brandis
Alexander Brandis
XSXiaomeng Sui
Xiaomeng Sui
AMArie Marcovich
Arie Marcovich
Purpose: To determine the long-term safety and efficacy of WST-D/near-infrared (NIR) corneal stiffening. Methods: One eye of 23 New Zealand White rabbits was de-epithelialized mechanically followed by topical application of 2.5 mg/mL WST11, combined with dextran-500 (WST-D) for 20 minutes. Subsequently, samples were irradiated with a NIR (755 nm) laser at 10 mW/cm2 for 30 minutes. Untreated fellow eyes served as controls. One week (n = 4), 1 month (n = 6), 4 months (n = 9), or 8 months (n = 4) after treatment rabbits were euthanized. Corneal strips were cut in superior–inferior direction for extensiometry testing (1, 4, and 8 months), and histologic sections were prepared for evaluation of keratocyte distribution (1 week and 8 months). Results: Elastic modulus after treatment was significantly higher than in paired controls (16.0 ± 2.3 MPa versus 9.6 ± 3.6 MPa [P = 0.008], 18.1 ± 4.5 MPa versus 12.6 ± 2.3 MPa [P = 0.003], and 18.6 ± 3.6 MPa versus 14.2 ± 3.6 MPa [P = 0.010], at 1, 4, and 8 months, respectively). A significant decrease in keratocyte count at the anterior stroma was observed directly after treatment (1.5 ± 1.7 vs. 19.0 ± 4.1 [P = 0.002]). At 8 months keratocyte repopulation appeared completed, with similar distribution in treated and untreated corneas (15.9 ± 1.1 vs. 14.5 ± 2.5 [P = 0.562]). Corneal thickness was comparable between treated and untreated corneas at all time points. Conclusions: WST-D/NIR treatment resulted in significant and persistent long-term increase in corneal stiffness. Initial keratocyte apoptosis in the anterior stroma is followed by repopulation to normal level at 8 months after treatment. The safe nature of NIR light allows treatment of corneas of any thickness without endangering corneal endothelium or deeper ocular structures, potentially benefiting patients deemed unsuitable for riboflavin/UV-A cross-linking.

21 June 2017 in Cornea
Verified
Journal Article
Open access
JBJurriaan Brekelmans
Jurriaan Brekelmans
AGAlexandra Goz
Alexandra Goz
MDMor M. Dickman
Mor M. Dickman
ABAlexander Brandis
Alexander Brandis
XSXiaomeng Sui
Xiaomeng Sui
AMArie Marcovich
Arie Marcovich
The aim of this study is to determine the effect of variation of the exposure time of near-infrared irradiation on corneal stiffening after a bacteriochlorophyll derivative (WST11) with dextran (WST-D) application. One hundred four paired eyes of 3-month-old New Zealand White rabbits were included in this study. Fifty-two eyes (ex vivo n = 34, in vivo n = 18) were mechanically deepithelialized, treated topically with WST-D, and irradiated at 10 mW/cm2 using a diode laser at 755 nm for 1, 5, or 30 minutes. Untreated fellow eyes served as controls. Corneoscleral rings were removed immediately after treatment (ex vivo), or 1 month after treatment (in vivo). Corneal strips were cut and underwent biomechanical stress–strain measurements. Ex vivo, the mean tangent elastic modulus was significantly higher in the treatment groups than in the control groups for 1, 5, and 30 minutes of irradiation, respectively, 6.06 MPa, 95% confidence interval (CI, 4.5–7.6) versus 14.02 MPa, 95% CI (10.2–17.8), n = 11, 4.8 MPa, 95% CI (3.9–5.7) versus 15.03 MPa, 95% CI (12–18.1), n = 11, and 7.8 MPa, 95% CI (5.6–10.02) versus 16.2 MPa, 95% CI (13.6–18.9), n = 11; P < 0.001 for all comparisons. In vivo, the mean elastic moduli in the treatment groups were significantly higher for 5 and 30 minutes of irradiation but not for 1 minute of irradiation, respectively, 11.4 MPa, 95% CI (8.5–14.2), versus 17.1 MPa, 95% CI (14.5–19.7), n = 5; P < 0.001, and 9.4 MPa, 95% CI (5.1–13.8) versus 16 MPa, 95% CI (13.1–19), n = 5; P < 0.01, and 11.3 MPa, 95% CI (6–16.6) versus 12.2 MPa, 95% CI (7.5–16.8), n = 5; P = 0.7. WST-D/near-infrared treatment using shortened irradiation time (1 minute ex vivo and 5 minutes in vivo) results in significant corneal stiffening, and this might provide an alternative to the currently applied riboflavin/ultraviolet A cross-linking. This is an open-access article distributed under the terms of the Creative Commons Attribution-Non Commercial-No Derivatives License 4.0 (CCBY-NC-ND), where it is permissible to download and share the work provided it is properly cited. The work cannot be changed in any way or used commercially without permission from the journal.

1 March 2021 in Experimental Eye Research
Verified
Journal Article
Closed access
OZOrtal Zaks
Ortal Zaks
DGDimitri Gaber
Dimitri Gaber
KBKeren Ben-Yaakov
Keren Ben-Yaakov
MSMaya Sharvit-Bader
Maya Sharvit-Bader
AGAlexa Goz
Alexa Goz
MAMichal Aharoni-Simon
Michal Aharoni-Simon