Annija Lace

Annija Lace

orcid

Research Focus & Metrics

Academic Career Length

8Years (2019-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
ALAnnija Lace
Annija Lace
DRDavid Ryan
David Ryan
MBMark Bowkett
Mark Bowkett
JCJohn Cleary
John Cleary
Chromium contamination of drinking water has become a global problem due to its extensive use in industry. The most commonly used methods for chromium detection in water are laboratory-based methods, such as atomic absorption spectroscopy and mass spectroscopy. Although these methods are highly selective and sensitive, they require expensive maintenance and highly trained staff. Therefore, there is a growing demand for cost effective and portable detection methods that would meet the demand for mass monitoring. Microfluidic detection systems based on optical detection have great potential for onsite monitoring applications. Furthermore, their small size enables rapid sample throughput and minimises both reagent consumption and waste generation. In contrast to standard laboratory methods, there is also no requirement for sample transport and storage. The aim of this study is to optimise a colorimetric method based on 1,5-diphenylcarbazide dye for incorporation into a microfluidic detection system. Rapid colour development was observed after the addition of the dye and samples were measured at 543 nm. Beer’s law was obeyed in the range between 0.03–3 mg·L−1. The detection limit and quantitation limit were found to be 0.023 and 0.076 mg·L−1, respectively.

24 March 2021 in Chemosensors
Verified
Journal Article
Open access
PDF file
ALAnnija Lace
Annija Lace
JCJohn Cleary
John Cleary
Heavy metal pollution of water has become a global issue and is especially problematic in some developing countries. Heavy metals are toxic to living organisms, even at very low concentrations. Therefore, effective and reliable heavy metal detection in environmental water is very important. Current laboratory-based methods used for analysis of heavy metals in water require sophisticated instrumentation and highly trained technicians, making them unsuitable for routine heavy metal monitoring in the environment. Consequently, there is a growing demand for autonomous detection systems that could perform in situ or point-of-use measurements. Microfluidic detection systems, which are defined by their small size, have many characteristics that make them suitable for environmental analysis. Some of these advantages include portability, high sample throughput, reduced reagent consumption and waste generation, and reduced production cost. This review focusses on developments in the application of microfluidic detection systems to heavy metal detection in water. Microfluidic detection strategies based on optical techniques, electrochemical techniques, and quartz crystal microbalance are discussed.

18 January 2019 in Molecules
Verified
Journal Article
Open access
PDF file
ALAnnija Lace
Annija Lace
DRDavid Ryan
David Ryan
MBMark Bowkett
Mark Bowkett
JCJohn Cleary
John Cleary
Arsenic contamination of drinking water is a global concern. Standard laboratory methods that are commonly used for arsenic detection in water, such as atomic absorption spectroscopy and mass spectroscopy, are not suitable for mass monitoring purposes. Autonomous microfluidic detection systems combined with a suitable colorimetric reagent could provide an alternative to standard methods. Moreover, microfluidic detection systems would enable rapid and cost efficient in situ monitoring of water sources without the requirement of laborious sampling. The aim of this study is to optimize a colorimetric method based on leucomalachite green dye for integration into a microfluidic detection system. The colorimetric method is based on the reaction of arsenic (III) with potassium iodate in acid medium to liberate iodine, which oxidizes leucomalachite green to malachite green. A rapid colour development was observed after the addition of the dye. Beer’s law was obeyed in the range between 0.07–3 µg mL−1. The detection limit and quantitation limit were found to be 0.19 and 0.64 µg mL−1, respectively.

16 October 2019 in Analytical Methods
Verified
Journal Article
Closed access
PDF file
ALAnnija Lace
Annija Lace
DRDavid Ryan
David Ryan
MBMark Bowkett
Mark Bowkett
JCJohn Cleary
John Cleary
This work describes a novel system for arsenic detection in water using leucomalachite green dye in a microfluidic platform. A simplified leucomalachite green method was integrated into a microfluidic detection system. In acidic medium arsenic is reacted with potassium iodate to liberate iodine, which in turn oxidises leucomalachite green to malachite green forming a green colour associated with an absorbance band in the visible region (λmax = 617 nm). A 1 : 1 v/v sample to reagent ratio was used for the analysis. Syringe pumps were used to introduce and transport reagents and samples into a PMMA microfluidic detection chip. The optical detection system consisted of a LED light source with a photodiode detector. The modified method can determine arsenic over the linear range of 0.3–2 mg L−1 with a limit of detection of 0.32 mg L−1. The average % RSD and recovery were 21.1% and 93.7%, respectively. The sample run time was optimised to 25 minutes. A range of environmental water samples were analysed using the modified method.