Christoph Forman

Christoph Forman

orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
25 February 2019 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
LMLiliana E. Ma
Liliana E. Ma
MMMichael Markl
Michael Markl
KCKelvin Chow
Kelvin Chow
HHHyungkyu Huh
Hyungkyu Huh
CFChristoph Forman
Christoph Forman
NJNing Jin
Ning Jin

22 March 2011 in Magnetic Resonance in Medicine
Verified
Journal Article
Open access
PDF file
MAMurat Aksoy
Murat Aksoy
CFChristoph Forman
Christoph Forman
MSMatus Straka
Matus Straka
SSStefan Skare
Stefan Skare
SHSamantha Holdsworth
Samantha Holdsworth
RBRoland Bammer
Roland Bammer
Head motion is a fundamental problem in brain MRI. The problem is further compounded in diffusion tensor imaging because of long acquisition times, and the sensitivity of the tensor computation to even small misregistration. To combat motion artifacts in diffusion tensor imaging, a novel real‐time prospective motion correction method was introduced using an in‐bore monovision system. The system consists of a camera mounted on the head coil and a self‐encoded checkerboard marker that is attached to the patient's forehead. Our experiments showed that optical prospective motion correction is more effective at removing motion artifacts compared to image‐based retrospective motion correction. Statistical analysis revealed a significant improvement in similarity between diffusion data acquired at different time points when prospective correction was used compared to retrospective correction (P < 0.001). Magn Reson Med, 2010.

1 January 2015 in Medical Image Analysis
Verified
Journal Article
Closed access
RGRobert Grimm
Robert Grimm
SFSebastian Fürst
Sebastian Fürst
MSMichael Souvatzoglou
Michael Souvatzoglou
CFChristoph Forman
Christoph Forman
JHJana Hutter
Jana Hutter
SNStephan G. Nekolla
Stephan G. Nekolla

1 January 2016 in Journal of Cardiovascular Magnetic Resonance
Verified
Journal Article
Open access
PDF file
TKTomoyuki Kido
Tomoyuki Kido
TKTeruhito Kido
Teruhito Kido
MNMasashi Nakamura
Masashi Nakamura
KWKouki Watanabe
Kouki Watanabe
MSMichaela Schmidt
Michaela Schmidt
TMTeruhito Mochizuki
Teruhito Mochizuki
Cardiovascular cine magnetic resonance (CMR) accelerated by compressed sensing (CS) is used to assess left ventricular (LV) function. However, it is difficult for prospective CS cine CMR to capture the complete end-diastolic phase, which can lead to underestimation of the end-diastolic volume (EDV), stroke volume (SV), and ejection fraction (EF), compared to retrospective standard cine CMR. This prospective study aimed to evaluate the diagnostic quality and accuracy of single-breath-hold full cardiac cycle CS cine CMR, acquired over two heart beats, to quantify LV volume in comparison to multi-breath-hold standard cine CMR. Eighty-one participants underwent standard segmented breath-hold cine and CS real-time cine CMR examinations to obtain a stack of eight contiguous short-axis images with same high spatial (1.7 × 1.7 mm2) and temporal resolution (41 ms). Two radiologists independently performed qualitative analysis of image quality (score, 1 [i.e., “nondiagnostic”] to 5 [i.e., “excellent”]) and quantitative analysis of the LV volume measurements. The total examination time was 113 ± 7 s for standard cine CMR and 24 ± 4 s for CS cine CMR (p < 0.0001). The CS cine image quality was slightly lower than standard cine (4.8 ± 0.5 for standard vs. 4.4 ± 0.5 for CS; p < 0.0001). However, all image quality scores for CS cine were above 4 (i.e., good). No significant differences existed between standard and CS cine MR for all quantitative LV measurements. The mean differences with 95 % confidence interval (CI), based on Bland–Altman analysis, were 1.3 mL (95 % CI, −14.6 – 17.2) for LV end-diastolic volume, 0.2 mL (95 % CI, −9.8 to10.3) for LV end-systolic volume, 1.1 mL (95 % CI, −10.5 to 12.7) for LV stroke volume, 1.0 g (95 % CI, −11.2 to 13.3) for LV mass, and 0.4 % (95 % CI, −4.8 – 5.6) for LV ejection fraction. The interobserver and intraobserver variability for CS cine MR ranged from −4.8 – 1.6 % and from −7.3 – 9.3 %, respectively, with slopes of the regressions ranging 0.88–1.0 and 0.86–1.03, respectively. Single-breath-hold full cardiac cycle CS real-time cine CMR could evaluate LV volume with excellent accuracy. It may replace multi-breath-hold standard cine CMR.

16 March 2020 in Magnetic Resonance in Medicine
Verified
Journal Article
Closed access
PDF file
EMEmilie Mussard
Emilie Mussard
THTom Hilbert
Tom Hilbert
CFChristoph Forman
Christoph Forman
RMReto Meuli
Reto Meuli
JTJean‐Philippe Thiran
Jean‐Philippe Thiran
TKTobias Kober
Tobias Kober

1 August 2019 in European Radiology
Verified
Journal Article
Closed access
PDF file
MVMathilde Vermersch
Mathilde Vermersch
BLBenjamin Longère
Benjamin Longère
ACAugustin Coisne
Augustin Coisne
MSMichaela Schmidt
Michaela Schmidt
CFChristoph Forman
Christoph Forman
FPFRANCOIS PONTANA
FRANCOIS PONTANA