Josep Arnabat-Domínguez

Prof. Dr. Josep Arnabat-Domínguez

Faculty of Medicin and health Science Dental School . Barcelona University
+1
orcid

Research Focus & Metrics

Academic Career Length

24Years (2003-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications


27 May 2011 in Lasers in Medical Science
Verified
Journal Article
Closed access
PDF file
MLMarta López-Ramírez
Marta López-Ramírez
MVMiguel Angel Vílchez-Pérez
Miguel Angel Vílchez-Pérez
JGJordi Gargallo
Jordi Gargallo
Josep Arnabat-DomínguezJosep Arnabat-Domínguez
Josep Arnabat-Domínguez
GCGay-Escoda Cosme
Gay-Escoda Cosme

1 January 2010 in Medicina Oral Patología Oral y Cirugia Bucal
Verified
Journal Article
Open access
ICI. Cercadillo-Ibarguren
I. Cercadillo-Ibarguren
AEA. Espana-Tost
A. Espana-Tost
Josep Arnabat-DomínguezJosep Arnabat-Domínguez
Josep Arnabat-Domínguez
EVEduard Valmaseda-Castellon
Eduard Valmaseda-Castellon
LBL. Berini-Aytes
L. Berini-Aytes
GCGay-Escoda Cosme
Gay-Escoda Cosme
The aim of this in vitro experimental study was to perform histological evaluation of the thermal effect produced on soft tissue irradiated with CO2, Er,Cr:YSGG or diode lasers. Porcine oral mucosa samples were irradiated with Er,Cr:YSGG laser at 1 W with and without water / air spray, at 2 W with and without water / air spray, and at 4 W with water / air spray, with CO2 laser at 1 W, 2 W, 10 W, 20 W continuous mode and 20 W pulsed mode and diode laser at 2 W, 5 W, and 10 W pulsed mode. The thermal effect was evaluated measuring the width of damaged tissue adjacent to the incision, stained positively for hyalinized tissue with Hematoxylin-Eosin and Masson Trichrome stains. Besides, histological changes in the irradiated tissue were described using subjective grading scales. The evaluated lasers developed a wide range of thermal damage with significant differences between groups. The samples with lowest thermal effect were those irradiated with Er,Cr:YSGG laser using water / air spray, followed by CO2 and diode lasers. Emission parameters of each laser system may influence the thermal damage inflicted on the soft tissue, however, the wave length of each laser determines the absorption rate characteristics of every tissue and the thermal effect.

21 July 2012 in Lasers in Medical Science
Verified
Journal Article
Closed access
PDF file
MAM. Artés-Ribas
M. Artés-Ribas
Josep Arnabat-DomínguezJosep Arnabat-Domínguez
Josep Arnabat-Domínguez
Andreu PuigdollersAndreu Puigdollers
Andreu Puigdollers

1 January 2012 in Medicina Oral Patología Oral y Cirugia Bucal
Verified
Journal Article
Open access
JPJ. Pie-Sanchez
J. Pie-Sanchez
AEAj. Espana-Tost
Aj. Espana-Tost
Josep Arnabat-DomínguezJosep Arnabat-Domínguez
Josep Arnabat-Domínguez
GCGay-Escoda Cosme
Gay-Escoda Cosme
To compare upper lip frenulum reinsertion, bleeding, surgical time and surgical wound healing in frenectomies performed with the CO2 laser versus the Er, Cr:YSGG laser. A prospective study was carried out on 50 randomized pediatric patients who underwent rhomboidal resection of the upper lip frenulum with either the CO2 laser or the Er,Cr:YSGG laser. Twenty-five patients were assigned to each laser system. All patients were examined at 7, 14, 21 days and 4 months after the operation in order to assess the surgical wound healing. Insertion of the frenulum, which was preoperatively located between the upper central incisors, migrated to the mucogingival junction as a result of using both laser systems in all patients. Only two patients required a single dose of 650 mg of paracetamol, one of either study group. CO2 laser registered improved intraoperative bleeding control results and shorter surgical times. On the other hand, the Er,Cr:YSGG laser achieved faster healing. Upper lip laser frenectomy is a simple technique that results in minimum or no postoperative swelling or pain, and which involves upper lip frenulum reinsertion at the mucogingival junction. The CO2 laser offers a bloodless field and shorter surgical times compared with the Er,Cr:YSGG laser. On the other hand, the Er,Cr:YSGG laser achieved faster wound healing.