Hanming Bian

Dr. Hanming Bian

Orthopedic Surgery, Peking Union Medical College Hospital, Beijing, China

Research Focus & Metrics

Academic Career Length

2Years (2025-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 January 2025 in Journal of Orthopaedic Translation
Verified
Journal Article
Open access
YZYiming Zhang
Yiming Zhang
JYJingzhou Yang
Jingzhou Yang
WWWentao Wan
Wentao Wan
QZQingqian Zhao
Qingqian Zhao
MDMingyuan Di
Mingyuan Di
QYQiang Yang
Qiang Yang
The materials for artificial bone scaffolds have long been a focal point in biomaterials research. Tantalum, with its excellent bioactivity and tissue compatibility, has gradually become a promising alternative material. 3D printing technology shows unique advantages in designing complex structures, reducing costs, and providing personalized customization in the manufacture of porous tantalum fusion cages. Here we report the pre-clinical large animal (sheep) study on the newly developed 3D printed biomimetic trabecular porous tantalum fusion cage for assessing the long-term intervertebral fusion efficacy and safety. Porous tantalum fusion cages were fabricated using laser powder bed fusion (LPBF) and chemical vapor deposition (CVD) methods. The fusion cages were characterized using scanning electron microscopy (SEM) and mechanical compression tests. Small-Tailed Han sheep served as the animal model, and the two types of fusion cages were implanted in the C3/4 cervical segments and followed for up to 12 months. Imaging techniques, including X-ray, CT scans, and Micro CT, were used to observe the bone integration of the fusion cages. Hard tissue sections were used to assess osteogenic effects and bone integration. The range of motion (ROM) of the motion segments was evaluated using a biomechanical testing machine. Serum biochemical indicators and pathological analysis of major organs were conducted to assess biocompatibility. X-ray imaging showed that both the 3D-printed and chemical vapor deposition porous tantalum fusion cages maintained comparable average intervertebral disc heights. Due to the presence of metal artifacts, CT and Micro CT imaging could not effectively analyze bone integration. Histomorphology data indicated that both the 3D-printed and chemical vapor deposition porous tantalum fusion cages exhibited similar levels of bone contact and integration at 3, 6, and 12 months, with bone bridging observed at 12 months. Both groups of fusion cages demonstrated consistent mechanical stability across all time points. Serum biochemistry showed no abnormalities, and no significant pathological changes were observed in the heart, liver, spleen, lungs, and kidneys. This study confirms that 3D-printed and chemical vapor deposition porous tantalum fusion cages exhibit comparable, excellent osteogenic effects and long-term biocompatibility. Additionally, 3D-printed porous tantalum fusion cages offer unique advantages in achieving complex structural designs, low-cost manufacturing, and personalized customization, providing robust scientific support for future clinical applications. The translational potential of this paper is to use 3D printed biomimetic trabecular porous tantalum spine fusion cage with bone trabecular structure and validating its feasibility in large animal models (sheep). This study provides a basis for further research into the clinical application of the 3D printed biomimetic trabecular porous tantalum spine fusion cage.

11 June 2025 in European Spine Journal
Verified
Journal Article
Open access
PDF file
TCTaoHuan Chen
TaoHuan Chen
Hanming BianHanming Bian
Hanming Bian
XPXiaoMei Peng
XiaoMei Peng
LWLiancheng Wang
Liancheng Wang
ZYZiMing Yao
ZiMing Yao
QYQiang Yang
Qiang Yang
Background Understanding the sagittal alignment of the pelvis and spine is essential for evaluating adolescent idiopathic scoliosis (AIS). Comparative studies of sagittal characteristics between AIS subtypes (especially lumbar scoliosis) and healthy Chinese adolescents remain limited. Objective This study evaluates differences in sagittal spinopelvic alignment between adolescent females with Lenke type 5 and 6 AIS and the healthy counterparts. Methods This study enrolled 156 female patients with AIS (118 Lenke type 5 and 38 Lenke type 6) and 110 age-matched healthy female adolescents. Spinal and pelvic parameters were measured from standing full spine anteroposterior and lateral radiographs, including the main Cobb angle (MCC), minor thoracic curve for type 6, thoracic kyphosis (TK), lumbar lordosis (LL), pelvic incidence (PI), sacral slope (SS), pelvic incidence to lumbar lordosis (PI-LL) mismatch, and pelvic tilt (PT). ANOVA compared the dependent variables between the two AIS subtypes (Lenke type 5 and 6) and healthy adolescents, and Pearson’s correlation coefficient (r) was used to determine the relationships among the parameters. Results PI, LL, SS and PI-LL did not significantly differ between AIS patients and controls. PT differed significantly among groups (p = 0.04). TK was significantly lower in Lenke type 6 compared to Lenke type 5 (p < 0.017 ). Subgroup analysis revealed no significant correlations between sagittal parameters and curve severity or direction in Lenke type 5. The difference between the major and minor curves of type 6 showed a statistically significant correlation with thoracic kyphosis (r = 0.372, p = 0.036) and PI-LL (r = -0.342, p = 0.043). There was statistically significant correlation between the MCC of Lenke type 6 and PI-LL (r =-0.38, p = 0.032). Conclusion PT reduction as a potential early compensatory trend in Lenke 5, though its predictive utility requires longitudinal validation. The stability of PT across different severities highlights its potential as a marker for early intervention, whereas Lenke 6 appeared to rely more on thoracic curvature adjustments. Dynamic changes in PT and TK may serve as early predictors for lumbar scoliosis progression and elucidate compensatory mechanisms of spinal curvature. These findings could provide clinical guidance for early prevention and targeted therapeutic interventions.

27 August 2025 in European Spine Journal
Verified
Journal Article
Open access
PDF file
TCTaoHuan Chen
TaoHuan Chen
Hanming BianHanming Bian
Hanming Bian
XPXiaoMei Peng
XiaoMei Peng
LWLiancheng Wang
Liancheng Wang
ZYZiMing Yao
ZiMing Yao
QYQiang Yang
Qiang Yang

Verified
Journal Article
Open access
PDF file
CLChenkai Li
Chenkai Li
YDYou Du
You Du
Hanming BianHanming Bian
Hanming Bian
YYYang Yang
Yang Yang
GLGuanfeng Lin
Guanfeng Lin
SWShengru Wang
Shengru Wang
Background: Currently, there is a lack of biomechanical studies on traditional dual-growing rods (TDGR) combined with apical osteotomy and short-segment fusion (hybrid technique, HT). This study compared the differences in clinical outcomes and biomechanics between TDGR and HT in the treatment of severe early-onset scoliosis (sEOS) via finite element analysis (FEA) and in vitro biomechanical experiments. Methods: Two scoliotic FEA models and 12 in vitro scoliotic models were created. In the FEA, the initial surgeries for TDGR and HT, two subsequent lengthenings, and up to 12 months of physeal spinal growth were simulated. In the in vitro biomechanical experiments, the initial surgeries were simulated. Correction outcomes, spinal height, and stress were compared between the TDGR and HT groups. Results: (1) FEA: Compared with TDGR, HT achieved better correction (62.4% vs. 36.2%) and a greater increase in spinal height (26.43 mm vs. 12.58 mm) after the initial surgery. During follow-up, HT resulted in better correction maintenance and could better sustain spinal growth than TDGR. HT reduced the stress on the proximal and distal instrumented vertebral bodies, junctional intervertebral discs, and instrumentation compared with TDGR. (2) In vitro biomechanical experiment: After the initial surgery, the mean Cobb angle of the main curve (24.58 ± 2.80° vs. 38.97 ± 3.23°) and AVT (8.87 ± 1.64 mm vs. 13.15 ± 3.58 mm) in the HT group were significantly lower than those in the TDGR group (p < 0.05). The increase in spinal height in the HT group was significantly greater than that in the TDGR group (3.83 ± 0.45 cm vs. 1.85 ± 0.72 cm, p < 0.001). Compared with TDGR, HT significantly decreased rod strain (p < 0.05). Conclusions: Compared with TDGR, HT can significantly improve correction outcomes and maintain spinal growth. Apical anchors can effectively disperse stress on the spine and instrumentation, which may reduce the risk of complications and potentially delay intervertebral disc degeneration, although clinical validation is required.