Bui Ngọc Ha

Mr. Bui Ngọc Ha

orcid

Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
30 September 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
DTDuong Thuy Tran
Duong Thuy Tran
BHBui Ngọc Ha
Bui Ngọc Ha
NTNgoc Toan Tran
Ngoc Toan Tran
DMDinh Thuy Mai
Dinh Thuy Mai
KHKhuat Quang Huy
Khuat Quang Huy
HHHai Quan Ho
Hai Quan Ho
Gamma-ray spectrometry using high-purity germanium (HPGe) detectors is the standard method for environmental radiation monitoring. Traditional analysis procedures rely on manual expert intervention to identify regions of interest (ROI), subtract background, and apply physical corrections, which limits computational efficiency on large datasets. Automating spectral analysis with deep neural networks requires a substantial amount of data. However, the domain shift between ideal simulated spectra and noisy experimental spectra degrades the predictive performance of purely data-driven models. This study evaluates a physics-informed neural network (PINN) framework, in which a 1D-ResNet is pre-trained on 6,000 MCNP-simulated spectra and fine-tuned on 640 experimental spectra. The loss function of the model embeds the radioactive isotope quantitative analysis equation. A Monte Carlo Dropout mechanism is applied during inference to estimate measurement uncertainty. The predictions from the PINN model achieve a coefficient of determination (R2) ranging from 0.937 to 0.949 when quantifying 40K, 232Th and 238U with lower RMSE and MAE compared to the standard 1D-ResNet architecture. Bland-Altman analysis demonstrates that the model-estimated uncertainty agrees with the benchmark method. The results from this study contribute to the development of an automated quantitative analysis pipeline that complies with radiation statistical principles, while determining operational limits when the system experiences significant hardware drift.

10 October 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
BHBui Ngọc Ha
Bui Ngọc Ha
DTDuong Thuy Tran
Duong Thuy Tran
DMDinh Thuy Mai
Dinh Thuy Mai
TTTran Ngoc Toan
Tran Ngoc Toan
TNTat Thang Nguyen
Tat Thang Nguyen
TATruong Minh Anh
Truong Minh Anh
Environmental radioactivity monitoring plays an important role in quantifying radiation exposure risks from natural radionuclides. Traditional spectral analysis procedures still have limitations regarding processing time and subjectivity due to human error. This study develops a customized analysis pipeline that applies a one-dimensional residual neural network (1D-ResNet) to directly quantify multi-isotope activity concentrations from 500 soil samples in Vietnam. By integrating the Savitzky-Golay smoothing technique and physics-informed data augmentation methods (MixUp and Poisson simulation), the model has solved the problem of training data scarcity. Prediction results on the test set show that 1D-ResNet outperforms shallow learning models (MLR, ANN) when handling complex decay chains, achieving a coefficient of determination () of 0.873 for and 0.859 for . The application of the Monte Carlo dropout technique has provided an uncertainty evaluation framework that meets the GUM guidelines for radiation metrology, achieving an empirical coverage probability (ECP) consistent with the nominal 95% confidence interval. However, explainability analysis using attention weight maps has revealed an issue: purely data-driven deep learning networks tend to shortcut learning by using Compton scattering regions for inference rather than photopeaks. From this discovery, the study lays the foundation for developing physics-informed neural networks (PINNs) to ensure future calibration transparency and traceability.

8 August 2026 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
HTHo Quang Tuan
Ho Quang Tuan
BHBui Ngọc Ha
Bui Ngọc Ha
TTThuy Duong Tran
Thuy Duong Tran
KHKhuat Quang Huy
Khuat Quang Huy
TTToan Ngoc Tran
Toan Ngoc Tran
HHHai Quan Ho
Hai Quan Ho
Accurate segmentation of non-small cell lung cancer (NSCLC) on positron emission tomography/computed tomography (PET/CT) is an essential prerequisite for automated metabolic tumor volume (MTV) quantification and staging. Although deep learning models achieve high performance on large-scale datasets, their generalization across different clinical domains is limited by variations in imaging protocols and patient demographics. This study aims to evaluate several deep learning architectures and investigate a transfer learning strategy to mitigate domain shift. Three architectures, including ResNet-backbone 3D U-Net, nnU-Net v2, and Swin UNETR, were benchmarked from scratch and compared with a fine-tuned nnU-Net initialized with AutoPET II weights. Results on the internal dataset showed that the fine-tuned nnU-Net achieved a Dice similarity coefficient (DSC) of 83.4 ± 6.5%, a 95% Hausdorff distance (HD95) of 5.1 ± 3.6 mm, and a precision of 89.6 ± 8.2%. Compared to the nnU-Net v2, the fine-tuned nnU-Net improved the absolute DSC by 6.8% while reducing local training time by 37.5% by bypassing the initial feature-learning phase. The fine-tuned nnU-Net model also demonstrated a high correlation between the MTV and the ground truth (Pearson r = 0.96, p < 0.001), indicating its potential as a reliable automated approach for quantitative MTV extraction and NSCLC prognostic-related analysis.

3 July 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
HTHo Quang Tuan
Ho Quang Tuan
BHBui Ngọc Ha
Bui Ngọc Ha
DTDuong Tran Thuy
Duong Tran Thuy
KHKhuat Quang Huy
Khuat Quang Huy
TTToan Ngoc Tran
Toan Ngoc Tran
HHHai Quan Ho
Hai Quan Ho
Accurate segmentation of non-small cell lung cancer (NSCLC) on positron emission tomography/computed tomography (PET/CT) is a critical foundation for automated metabolic tumor volume (MTV) quantification and staging. Although deep learning models achieve high performance on large-scale datasets, their generalization across different clinical domains remains challenged by variations in imaging protocols and patient demographics. This study aims to evaluate several deep learning architectures and investigate a transfer learning strategy to mitigate domain shift on a dataset of 400 PET/CT scans from Vietnamese NSCLC patient cohort. Three architectures, including 3D U-Net, nnU-Net v2, and Swin UNETR, were benchmarked from scratch and compared with a fine-tuned nnU-Net initialized with AutoPET II weights. Results on the internal dataset showed that the fine-tuned nnU-Net achieved a Dice similarity coefficient (DSC) of 83.4 ± 6.5%, a 95% Hausdorff distance (HD95) of 5.1 ± 3.6 mm, and precision of 89.6 ± 8.2%. Compared to the nnU-Net v2, the fine-tuned nnU-Net improved the absolute DSC by 6.8% while reducing the training time by 37.5%. The fine-tuned nnU-Net model also demonstrated a good correlation between the MTV and the ground truth (Pearson r = 0.96, p < 0.001), indicating its potential as a reliable automated approach for quantitative MTV extraction and NSCLC prognostic related analysis.

22 April 2026 in Journal of Environmental Radioactivity
Verified
Journal Article
Closed access
TTThuy Duong Tran
Thuy Duong Tran
BHBui Ngọc Ha
Bui Ngọc Ha
DMDinh Thuy Mai
Dinh Thuy Mai
TBTien Hung Bui
Tien Hung Bui
NTNguyen Tat Thang
Nguyen Tat Thang
HHHai Quan Ho
Hai Quan Ho

8 July 2026 in Engineering and Technology For Sustainable Development
Verified
Journal Article
Open access
PDF file
BHBui Ngọc Ha
Bui Ngọc Ha
TDThuy Mai Dinh
Thuy Mai Dinh
TTThuy Duong Tran
Thuy Duong Tran
Simulation is a widely used tool in medical physics, enabling a deeper understanding of intrinsic physical phenomena within systems. In medical physics, simulation is considered essential for research and training due to the unique nature of medical physics equipment, such as X-ray imaging, tomography, and radiotherapy devices, which are used for human diagnosis and treatment. Ethical constraints prevent the use of human subjects in experimental research and training, necessitating the use of phantoms that closely mimic human anatomy. However, measurements on phantoms do not fully replicate radiation interactions with human tissue, highlighting the need for simulation combined with experimental measurements to enhance the accuracy and effectiveness of diagnosis and treatment in medical physics. This article presents the development of medical physics simulation software with an intuitive, user-friendly graphical interface. The software supports medical physics engineers in professional training and research, optimizing diagnostic and radiotherapy techniques to improve the quality of patient diagnosis and treatment.