Tien Hung Bui

Mr. Tien Hung Bui

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
15 March 2021 in Nuclear Science and Technology
Verified
Journal Article
Closed access
PDF file
NBNgoc Ha Bui
Ngoc Ha Bui
TBTien Hung Bui
Tien Hung Bui
TTThuy Duong Tran
Thuy Duong Tran
KTKim Tuan Tran
Kim Tuan Tran
NTNgoc Toan Tran
Ngoc Toan Tran
: 3D Filtered Back Projection (FBP) is a three-dimensional reconstruction algorithm usually used in Cone Beam Computed Tomography (CBCT) system. FBP is one of the most popular algorithms due to its reconstruction is fast while quality of the result is acceptable. It can also handle a more considerable amount of data with same computer performance with other algorithms. However, the quality of a reconstructed image by the FBP algorithm strongly depends on spatial filters and denoising filters applied to projections. In this paper an evaluation of the reconstructed image quality of the CBCT system by using different denoising filters and spatial filters to find out the best filters for the CBCT system is performed. The result shows that, there is a significantly decrease of the noise of projection with the combination of Median and Gaussian filters. The reconstructed image has high resolution with Cosine filter and becomes more sharpen with Hanning filter.

24 March 2023 in Atom Indonesia
Verified
Journal Article
Open access
PDF file
TBTien Hung Bui
Tien Hung Bui
DTDuong Thuy Tran
Duong Thuy Tran
BHB. N. Ha
B. N. Ha
This study used PHITS and Geant4 code packages to simulate a Leksell Gamma Knife system in order to determine radiation dose distribution in two types of phantoms. The results observed in the water phantom with configurations of single source and 201 sources are in good accord with the prior research, including both simulation and experiment. Several characteristics of Leksell Gamma Knife 4C, such as dose profiles, output factor, FWHM, and penumbra size, are calculated based on Monte Carlo simulations, which show the best consistency with other results. The output factors for collimators of 14 mm, 8 mm, and 4 mm are 0.984, 0.949, and 0.872, respectively. The simulation results with an adult mesh-type reference phantom reveal considerable similarities with the established radiosurgery plans. It indicates that the absorbed dose in brain tumors was highest when utilizing the 18 mm collimator and subsequently reduced with collimator size to 0.65, 0.25, and 0.5 with the 14 mm, 8 mm, and 4 mm collimators, respectively. The absorbed dose has a very low value for other essential organs and decreases with distance from the brain tumor. These findings may explain why the dose to organs decreases linearly as target distance, volume, and collimator size increase.

10 October 2026 in SSRN Electronic Journal
Verified
Preprint
Open access
BHBui Ngọc Ha
Bui Ngọc Ha
DTDuong Thuy Tran
Duong Thuy Tran
DMDinh Thuy Mai
Dinh Thuy Mai
TTTran Ngoc Toan
Tran Ngoc Toan
TNTat Thang Nguyen
Tat Thang Nguyen
TATruong Minh Anh
Truong Minh Anh
Environmental radioactivity monitoring plays an important role in quantifying radiation exposure risks from natural radionuclides. Traditional spectral analysis procedures still have limitations regarding processing time and subjectivity due to human error. This study develops a customized analysis pipeline that applies a one-dimensional residual neural network (1D-ResNet) to directly quantify multi-isotope activity concentrations from 500 soil samples in Vietnam. By integrating the Savitzky-Golay smoothing technique and physics-informed data augmentation methods (MixUp and Poisson simulation), the model has solved the problem of training data scarcity. Prediction results on the test set show that 1D-ResNet outperforms shallow learning models (MLR, ANN) when handling complex decay chains, achieving a coefficient of determination () of 0.873 for and 0.859 for . The application of the Monte Carlo dropout technique has provided an uncertainty evaluation framework that meets the GUM guidelines for radiation metrology, achieving an empirical coverage probability (ECP) consistent with the nominal 95% confidence interval. However, explainability analysis using attention weight maps has revealed an issue: purely data-driven deep learning networks tend to shortcut learning by using Compton scattering regions for inference rather than photopeaks. From this discovery, the study lays the foundation for developing physics-informed neural networks (PINNs) to ensure future calibration transparency and traceability.

15 March 2022 in Atom Indonesia
Verified
Journal Article
Open access
PDF file
DTD. T. Thuy
D. T. Thuy
TBTien Hung Bui
Tien Hung Bui
HNH. B. Ngoc
H. B. Ngoc
TKT. T. Kim
T. T. Kim
TNT. T. Ngoc
T. T. Ngoc
Detection of Spoilage in Canned Pasteurized Milk Using the Radiographic Imaging Technique

1 June 2022 in Journal of Science, Natural Science
Verified
Journal Article
Closed access
TBTien Hung Bui
Tien Hung Bui
DTDuong Tran Thuy
Duong Tran Thuy
HNHa Bui Ngoc
Ha Bui Ngoc
TTThao Nguyen Thi
Thao Nguyen Thi
In the field of medical physics, determining the dosage for organs is a very complex problem because it is impossible to directly measure the dosage inside a living person's body. Therefore, in order to estimate the dosage, one usually has to use phantoms. For dosage determination and safety assessment, Monte Carlo simulation programs and today's phantoms have become indispensable tools. There are already several standard phantoms in the world but they do not represent biological characteristics by region or for a specific object. Another method used to build characteristic phantoms is done through computed tomography (CT) images and the Hounsfield index. The method requires to convert the grayscale value of each pixel element into the Hounsfield index. As such, it can only be applied to CT imaging. To overcome this shortcoming, this study has developed a program based on a new process that can convert images to geometric format for MCNP\PHITS. The new procedure that we propose will allow researchers to describe the anatomical structures more accurately and be specific to each patient.

8 August 2026 in Journal of Imaging
Verified
Journal Article
Open access
PDF file
HTHo Quang Tuan
Ho Quang Tuan
BHBui Ngọc Ha
Bui Ngọc Ha
TTThuy Duong Tran
Thuy Duong Tran
KHKhuat Quang Huy
Khuat Quang Huy
TTToan Ngoc Tran
Toan Ngoc Tran
HHHai Quan Ho
Hai Quan Ho
Accurate segmentation of non-small cell lung cancer (NSCLC) on positron emission tomography/computed tomography (PET/CT) is an essential prerequisite for automated metabolic tumor volume (MTV) quantification and staging. Although deep learning models achieve high performance on large-scale datasets, their generalization across different clinical domains is limited by variations in imaging protocols and patient demographics. This study aims to evaluate several deep learning architectures and investigate a transfer learning strategy to mitigate domain shift. Three architectures, including ResNet-backbone 3D U-Net, nnU-Net v2, and Swin UNETR, were benchmarked from scratch and compared with a fine-tuned nnU-Net initialized with AutoPET II weights. Results on the internal dataset showed that the fine-tuned nnU-Net achieved a Dice similarity coefficient (DSC) of 83.4 ± 6.5%, a 95% Hausdorff distance (HD95) of 5.1 ± 3.6 mm, and a precision of 89.6 ± 8.2%. Compared to the nnU-Net v2, the fine-tuned nnU-Net improved the absolute DSC by 6.8% while reducing local training time by 37.5% by bypassing the initial feature-learning phase. The fine-tuned nnU-Net model also demonstrated a high correlation between the MTV and the ground truth (Pearson r = 0.96, p < 0.001), indicating its potential as a reliable automated approach for quantitative MTV extraction and NSCLC prognostic-related analysis.