Background/Objectives: Radiography is an essential and low-cost diagnostic method in pulmonary medicine that is used for the early detection and monitoring of lung diseases. An adequate and consistent image quality (IQ) is crucial to ensure accurate diagnosis and effective patient management. This pilot study evaluates the feasibility and effectiveness of the International Atomic Energy Agency (IAEA)’s remote and automated quality control (QC) methodology, which has been tested in multiple imaging centers. Methods: The data, collected between April and December 2022, included 47 longitudinal data sets from 22 digital radiographic units. Participants submitted metadata on the radiography setup, exposure parameters, and imaging modes. The database comprised 968 exposures, each representing multiple image quality parameters and metadata of image acquisition parameters. Python scripts were developed to collate, analyze, and visualize image quality data. Results: The pilot survey identified several critical issues affecting the future implementation of the IAEA method, as follows: (1) difficulty in accessing raw images due to manufacturer restrictions, (2) variability in IQ parameters even among identical X-ray systems and image acquisitions, (3) inconsistencies in phantom construction affecting IQ values, (4) vendor-dependent DICOM tag reporting, and (5) large variability in SNR values compared to other IQ metrics, making SNR less reliable for image quality assessment. Conclusions: Cross-comparisons among radiography systems must be taken with cautious because of the dependence on phantom construction and acquisition mode variations. Awareness of these factors will generate reliable and standardized quality control programs, which are crucial for accurate and fair evaluations, especially in high-frequency chest imaging.
7 February 2020 in International Journal of Radiation Biology
Purpose – Our aim was to design a compact and cost-effective optical microscopic system for automated non-fluorescent micronucleus (MN) scoring whose performance can reach the accuracy of visual scoring with the help of minimal user interaction and also gives an option for fully automatic scoring with an accuracy suitable for triage purposes. Material and methods – The concept of Radometer MN-Series microscopic system (RS-MN) designed by Radosys was to develop hardware and software layers in parallel in order to optimize the performance in automated MN scoring. A MN assay slide is automatically scanned by the RS-MN then the binucleated cells and micronuclei are automatically identified. Processing 1000 cells takes 10-60 minutes by automatic scoring (scanning plus image processing) depending on sample quality and required accuracy. The manual revision of the cell gallery takes an extra 10 minutes per sample. Dose response curves are determined for manual, automatic and semi-automatic scoring methods. Results – The combination of object-sensitive autofocusing method and the multi-layer image acquisition is able to reduce the minimum resolvable dose by 14%. The MN yields obtained from the manual, semi-automatic and automatic scoring methods are well correlating (Pearson correlation coefficients are between 0.977-0.998). In order to compare the reliability of the results of visual and automatic scoring, an extended analysis on uncertainty contributors was performed. For a dose of 1 Gy the estimated relative uncertainty from the Poisson characteristics of MN yield is 17-19% for the manual and 20-38% for the automated scoring. Other uncertainty factors (differences in donor radiosensitivity, scorer performance, and sample preparations) can contribute to this error fall within a similar range: 3-16%. Taking into account all of the possible uncertainties, the minimum resolvable dose for the manual (0.48 Gy) is the two-thirds of that of the automatic scoring (0.61 Gy). Conclusions – The results verify that the fully automatic mode of Radometer MN-Series is suitable for triage purposes. The performance of the user interacted semi-automatic mode is comparable with the reference manual scoring. Its performance reaches up to other non-fluorescent automatic systems and offers a compact and cost-effective alternative.
Automatizing the scoring of the cytokinesis-blocked micronucleus assay spares a lot of valuable time. The dose-effect relationship can be applied reliably for dose estimation if the quality of the slides is the same from the perspective of the used image processing algorithm. This aspect brings in additional requirements against the quality of the slides compared to the conventional visual scoring. An add-in software was created to the non-fluorescent RS-MN automatic MN scoring system which is capable of measuring quantitatively the degree of typical anomalies. The image processing is less reliable when the presence of these anomalies is more frequent. The behavior of the designed sample quality parameters (SQPs) was tested on in vitro irradiated peripheral blood samples (0, 1, and 2 Gy) obtained from a healthy donor and also on samples from patients undergoing low dose-rate brachytherapy. We examined 20 different SQPs and identified two that are independent and correlate significantly with the error of the fully automatic MN frequency. One is related to the size of the cells and the other reflects the homogeneity of the environment. An equation was established which presents a connection between the error of the auto MN frequency and the SQPs. By adding a fourth cleaning step to the conventional sample preparation and changing the pre-dripping temperature of the slide, the SQP can be modified, and consequently, the sample quality can be improved. The gain in accuracy is 54 ± 10 MN per 1000 binucleated cells, which corresponds to the effects of 0.5 Gy. Around the lowest limit of detection (<0.5 Gy), it means a 50–100% drop in the error of dose, which is significant. With sample quality harmonization, the positive predictive value was raised to 80–93% depending on the dose. With the technique described in this paper, the suitability for automated scoring of a micronucleus slide can be tested quantitatively and objectively. A method is presented with which in some cases the uncertainty of the assessed doses due to variance in sample quality can be decreased or if it is not possible its bias can be predicted. The proposed protocol leads to more reliable estimation of dose. The SQPs are designed in a way that they have the potential to be adapted to similar systems.
Background: There are limited data comparing the effect of different radiotherapy techniques on healthy cells in the same patient group. Furthermore, assessing radiotherapy-induced T-lymphocyte damage may be important given the increasing use of immunotherapy. We aimed to measure and compare DNA damage in T-lymphocytes after four types of radiotherapy for low- and intermediate-risk prostate cancer and monitor their persistence for five years. Methods: A prospective comparison of patients receiving conventional LINAC (linear accelerator) (70–78 Gy), CyberKnife teletherapy (37.5–40 Gy), low-dose-rate brachytherapy (LDR; 145 Gy) and high-dose-rate brachytherapy (HDR; 19–21 Gy was performed using the chromosome aberration technique (at 3, 6, 9, 12, 24, 36, 48, and 60 months, 192 patients). Multivariate regression analyses were conducted to assess the predictive potential of chromosome aberrations for toxicities. Results: We found that teletherapy techniques (conventional LINAC and CyberKnife therapy) caused 1.6–3.6-fold more chromosomal aberrations than brachytherapy. At three months, 4.4–13.1% of T-lymphocytes were damaged. Five years after treatment, the total aberration values of conventional LINAC and LDR brachytherapy patients were still significantly higher than those before treatment (p < 0.001 for LINAC and p = 0.011 for LDR). Significant regression models suggested that total aberrations or aberrant cell frequency might predict toxicities in addition to the biologically effective dose (BED) and the irradiated volume (V100%) (p = 0.020 for the model including total aberrations, p = 0.010 for the model including aberrant cell frequency). Conclusions: We observed a lower chromosome aberration frequency and fewer toxicities in brachytherapy patients. We also demonstrated that long-term T-lymphocyte damage depends on the type of radiotherapy.