Mohammed Jamaan Alsahli

Dr. Mohammed Jamaan Alsahli

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 September 2024 in Journal of Medical Internet Research
Verified
Journal Article
Open access
AAAlaa Abd-alrazaq
Alaa Abd-alrazaq
HAHania Aslam
Hania Aslam
RARawan AlSaad
Rawan AlSaad
MAMohammed Jamaan Alsahli
Mohammed Jamaan Alsahli
AAArfan Ahmed
Arfan Ahmed
JSJavaid Sheikh
Javaid Sheikh
Background: Early detection of sleep apnea, the health condition where airflow either ceases or decreases episodically during sleep, is crucial to initiate timely interventions and avoid complications. Wearable artificial intelligence (AI), the integration of AI algorithms into wearable devices to collect and analyze data to offer various functionalities and insights, can efficiently detect sleep apnea due to its convenience, accessibility, affordability, objectivity, and real-time monitoring capabilities, thereby addressing the limitations of traditional approaches such as polysomnography. Objective: The objective of this systematic review was to examine the effectiveness of wearable AI in detecting sleep apnea, its type, and its severity. Methods: Our search was conducted in 6 electronic databases. This review included English research articles evaluating wearable AI’s performance in identifying sleep apnea, distinguishing its type, and gauging its severity. Two researchers independently conducted study selection, extracted data, and assessed the risk of bias using an adapted Quality Assessment of Studies of Diagnostic Accuracy-Revised tool. We used both narrative and statistical techniques for evidence synthesis. Results: Among 615 studies, 38 (6.2%) met the eligibility criteria for this review. The pooled mean accuracy, sensitivity, and specificity of wearable AI in detecting apnea events in respiration (apnea and nonapnea events) were 0.893, 0.793, and 0.947, respectively. The pooled mean accuracy of wearable AI in differentiating types of apnea events in respiration (normal, obstructive sleep apnea, central sleep apnea, mixed apnea, and hypopnea) was 0.815. The pooled mean accuracy, sensitivity, and specificity of wearable AI in detecting sleep apnea were 0.869, 0.938, and 0.752, respectively. The pooled mean accuracy of wearable AI in identifying the severity level of sleep apnea (normal, mild, moderate, and severe) and estimating the severity score (Apnea-Hypopnea Index) was 0.651 and 0.877, respectively. Subgroup analyses found different moderators of wearable AI performance for different outcomes, such as the type of algorithm, type of data, type of sleep apnea, and placement of wearable devices. Conclusions: Wearable AI shows potential in identifying and classifying sleep apnea, but its current performance is suboptimal for routine clinical use. We recommend concurrent use with traditional assessments until improved evidence supports its reliability. Certified commercial wearables are needed for effectively detecting sleep apnea, predicting its occurrence, and delivering proactive interventions. Researchers should conduct further studies on detecting central sleep apnea, prioritize deep learning algorithms, incorporate self-reported and nonwearable data, evaluate performance across different device placements, and provide detailed findings for effective meta-analyses.

31 January 2024 in Journal of Medical Internet Research
Verified
Journal Article
Open access
AAAlaa Abd-alrazaq
Alaa Abd-alrazaq
MAMohannad Alajlani
Mohannad Alajlani
RAReham Ahmad
Reham Ahmad
RARawan AlSaad
Rawan AlSaad
SASarah Aziz
Sarah Aziz
JSJavaid Sheikh
Javaid Sheikh
Background: Students usually encounter stress throughout their academic path. Ongoing stressors may lead to chronic stress, adversely affecting their physical and mental well-being. Thus, early detection and monitoring of stress among students are crucial. Wearable artificial intelligence (AI) has emerged as a valuable tool for this purpose. It offers an objective, noninvasive, nonobtrusive, automated approach to continuously monitor biomarkers in real time, thereby addressing the limitations of traditional approaches such as self-reported questionnaires. Objective: This systematic review and meta-analysis aim to assess the performance of wearable AI in detecting and predicting stress among students. Methods: Search sources in this review included 7 electronic databases (MEDLINE, Embase, PsycINFO, ACM Digital Library, Scopus, IEEE Xplore, and Google Scholar). We also checked the reference lists of the included studies and checked studies that cited the included studies. The search was conducted on June 12, 2023. This review included research articles centered on the creation or application of AI algorithms for the detection or prediction of stress among students using data from wearable devices. In total, 2 independent reviewers performed study selection, data extraction, and risk-of-bias assessment. The Quality Assessment of Diagnostic Accuracy Studies–Revised tool was adapted and used to examine the risk of bias in the included studies. Evidence synthesis was conducted using narrative and statistical techniques. Results: This review included 5.8% (19/327) of the studies retrieved from the search sources. A meta-analysis of 37 accuracy estimates derived from 32% (6/19) of the studies revealed a pooled mean accuracy of 0.856 (95% CI 0.70-0.93). Subgroup analyses demonstrated that the accuracy of wearable AI was moderated by the number of stress classes (P=.02), type of wearable device (P=.049), location of the wearable device (P=.02), data set size (P=.009), and ground truth (P=.001). The average estimates of sensitivity, specificity, and F1-score were 0.755 (SD 0.181), 0.744 (SD 0.147), and 0.759 (SD 0.139), respectively. Conclusions: Wearable AI shows promise in detecting student stress but currently has suboptimal performance. The results of the subgroup analyses should be carefully interpreted given that many of these findings may be due to other confounding factors rather than the underlying grouping characteristics. Thus, wearable AI should be used alongside other assessments (eg, clinical questionnaires) until further evidence is available. Future research should explore the ability of wearable AI to differentiate types of stress, distinguish stress from other mental health issues, predict future occurrences of stress, consider factors such as the placement of the wearable device and the methods used to assess the ground truth, and report detailed results to facilitate the conduct of meta-analyses. Trial Registration: PROSPERO CRD42023435051; http://tinyurl.com/3fzb5rnp

8 January 2026 in Journal of Medical Internet Research
Verified
Journal Article
Open access
MAMais Alkhateeb
Mais Alkhateeb
ANAjisha Nayeem
Ajisha Nayeem
AAArfan Ahmed
Arfan Ahmed
MAMohammed Jamaan Alsahli
Mohammed Jamaan Alsahli
JSJavaid Sheikh
Javaid Sheikh
AAAlaa Abd-alrazaq
Alaa Abd-alrazaq
Background: Postpartum depression (PPD) affects up to 20% of mothers globally. Early detection is vital for better outcomes, yet screening lacks scalability and predictive power. Artificial intelligence (AI)—through machine learning, deep learning, and natural language processing—enhances the early identification of mothers at risk with greater accuracy. Objective: This study aims to systematically map the existing literature on AI-based methods for detecting and predicting PPD. Methods: This scoping review was conducted in accordance with the PRISMA-ScR (Preferred Reporting Items for Systematic Reviews and Meta-Analyses Extension for Scoping Reviews) guidelines. We included empirical studies that applied AI techniques to detect or predict PPD and were published in peer-reviewed journals, conference proceedings, or dissertations. Studies were excluded if they were nonempirical (eg, reviews, editorials, and abstracts), not published in English, focused on general perinatal mental health without a specific emphasis on PPD, or used AI solely for monitoring or treatment rather than prediction or detection. We systematically searched 8 databases—MEDLINE, Embase, PsycINFO, CINAHL, Scopus, IEEE Xplore, ACM Digital Library, and Google Scholar—from inception through February 28, 2025. The search strategy was supplemented by backward and forward reference screening and biweekly alerts to capture newly published studies. Two independent (M [Alkhateeb] and A [Nayeem])reviewers (M [Alkhateeb] and A [Nayeem]) screened the retrieved studies, with disagreements resolved by a third reviewer (AA [Alrazaq]). Data were extracted by 2 independent reviewers using a standardized extraction form capturing study characteristics, AI model types, data sources, features, preprocessing, validation strategies, and performance metrics. A formal risk-of-bias assessment was not performed due to the scoping nature of the review. All extracted data were synthesized narratively. Results: Out of 503 retrieved studies, 65 met the inclusion criteria. The United States contributed the largest proportion of studies (18/65, 27.7%). The highest number of publications occurred in 2024 (17/65, 26%). Most included studies were journal articles (46/65, 71%). Short-term postpartum outcomes (≤12 weeks) were most frequently assessed (20/65, 30.8%). Most included studies (52/65, 80%) applied AI models for predicting PPD, while 14 of 65 (22%) studies used them for detection. Sociodemographic data were most frequently used (49/65, 75.4%), followed by psychological data (44/65, 68%) and obstetric data (35/65, 55%). Data preprocessing mostly relied on basic scaling (51/65, 79%) and some missing data imputation (29/65, 44.6%). Machine learning dominated (57/65, 87.7%), especially random forest, support vector machines, and logistic regression. Internal validation (k-fold, hold-out) was standard, while external validation was scarce. Ensemble-based boosting models consistently demonstrated superior performance across key metrics, highlighting their potential for accurate and scalable PPD prediction. Current studies suffer from limited sample sizes, geographic bias, lack of standardized feature sets, minimal external validation, and inconsistent reporting of comprehensive model metrics. Conclusions: This scoping review analyzes 65 studies on AI in PPD, highlighting dominant use of classical machine learning, limited deep learning adoption, underuse of advanced preprocessing, inconsistent validation, and reliance on structured, unimodal data—mainly sociodemographic, clinical, and obstetric features.

31 October 2025 in Journal of Medical Internet Research
Verified
Journal Article
Open access
SASarah Aziz
Sarah Aziz
AAAmal A M Ali
Amal A M Ali
HAHania Aslam
Hania Aslam
NANoor Ul Ain
Noor Ul Ain
ATAmna Tariq
Amna Tariq
JSJavaid Sheikh
Javaid Sheikh
Background: Epilepsy affects approximately 50 million people globally and imposes a substantial clinical and societal burden, requiring continuous and personalized monitoring for effective management. Wearable artificial intelligence (AI) technologies offer a promising solution by leveraging physiological signals and machine learning for seizure detection and prediction. While various approaches have been proposed, a comprehensive overview summarizing these advances and challenges is still needed. Objective: This review aims to comprehensively explore and map the existing literature on AI-driven wearable technologies for epilepsy, identifying device characteristics, AI methodologies, biosignal measurements, validation approaches, and research gaps. Methods: A scoping review was conducted following the PRISMA-ScR (Preferred Reporting Items for Systematic Reviews and Meta-Analyses Extension for Scoping Reviews) guidelines. A systematic search was performed across six electronic databases (Scopus, MEDLINE, Embase, ACM Digital Library, IEEE Xplore, and Google Scholar) to identify relevant studies published up to December 2023. We included studies that developed AI algorithms for epilepsy using noninvasive wearable devices (eg, smartwatches, smart clothing) and excluded those using nonwearables or in-body devices. Eligible publication types included journal articles, conference papers, and dissertations. Study selection and data extraction were performed independently by six reviewers. The extracted data were synthesized narratively. Results: A total of 67 studies met the inclusion criteria. Research in this domain has increased significantly since 2021, with India, the United States, and China leading contributions. The studies examined both commercial (n=31, 46.3%) and noncommercial (n=31, 46.3%) wearable devices, with Empatica smart bands being the most frequently used. The primary biosignals monitored included activity measures (n=36, 53.7%), cardiovascular metrics (n=33, 49.3%), brain activity (n=24, 35.8%), and skin conductance (n=23, 34.3%). The most common AI models were support vector machines (n=28, 41.8%), random forests (n=14, 20.9%), and convolutional neural networks (n=10, 14.9%). Most models focused on seizure detection (n=54, 80.6%) compared to seizure prediction (n=14, 20.9%), reflecting a research imbalance that suggests the need for further development in predictive analytics. Sensitivity (n=54, 80.6%) was the most frequently reported performance metric, indicating a focus on identifying seizures; however, comprehensive clinical validation remains limited. Closed-source data predominated (n=44, 65.7%), limiting the generalizability of findings. The most used validation methods were leave-one-out cross-validation (n=21, 31.3%) and k-fold cross-validation (n=20, 29.9%), while video electroencephalography served as the primary reference standard (n=35, 52.2%). Conclusions: Wearable AI technologies show significant promise in epilepsy management, offering real-time, continuous monitoring and early seizure detection. To realize clinical impact, future research should prioritize the standardization of validation methods, promote open data exchange for reproducibility, and develop energy-efficient algorithms that support real-world deployment in wearable devices.

8 March 2022 in Journal of Medical Internet Research
Verified
Journal Article
Open access
MAMohammed Jamaan Alsahli
Mohammed Jamaan Alsahli
AAAlaa Abd-alrazaq
Alaa Abd-alrazaq
MHMowafa Househ
Mowafa Househ
Stathis KonstantinidisStathis Konstantinidis
Stathis Konstantinidis
Holly BlakeHolly Blake
Holly Blake
Background: The prevalence of type 2 diabetes mellitus (T2DM) is increasing worldwide. Physical activity (PA) is an important aspect of self-care and first line management for T2DM. SMS text messaging can be used to support self-management in people with T2DM, but the effectiveness of mobile text message–based interventions in increasing PA is still unclear. Objective: This study aims to assess the effectiveness of mobile phone messaging on PA in people with T2DM by summarizing and pooling the findings of previous literature. Methods: A systematic review was conducted to accomplish this objective. Search sources included 5 bibliographic databases (MEDLINE, Cochrane Library, CINAHL, Web of Science, and Embase), the search engine Google Scholar (Google Inc), and backward and forward reference list checking of the included studies and relevant reviews. A total of 2 reviewers (MA and AA) independently carried out the study selection, data extraction, risk of bias assessment, and quality of evidence evaluation. The results of the included studies were synthesized narratively and statistically, as appropriate. Results: We included 3.8% (6/151) of the retrieved studies. The results of individual studies were contradictory regarding the effectiveness of mobile text messaging on PA. However, a meta-analysis of the results of 5 studies showed no statistically significant effect (P=.16) of text messages on PA in comparison with no intervention. A meta-analysis of the findings of 2 studies showed a nonsignificant effect (P=.14) of text messages on glycemic control. Of the 541 studies, 2 (0.4%) found a nonsignificant effect of text messages on anthropometric measures (weight and BMI). Conclusions: We could not draw a definitive conclusion regarding the effectiveness of text messaging on PA, glycemic control, weight, or BMI among patients with T2MD, given the limited number of included studies and their high risk of bias. Therefore, there is a need for more high-quality primary studies. Trial Registration: PROSPERO International Prospective Register of Systematic Reviews CRD42020156465; https://www.crd.york.ac.uk/prospero/display_record.php?RecordID=156465

21 March 2025 in JMIR Nursing
Verified
Journal Article
Open access
MAMohammed Jamaan Alsahli
Mohammed Jamaan Alsahli
AAAlaa Abd-alrazaq
Alaa Abd-alrazaq
DFDalia M Fathy
Dalia M Fathy
SASahar A Abdelmohsen
Sahar A Abdelmohsen
OGOlfat Gushgari
Olfat Gushgari
AEAmal Elnabasy
Amal Elnabasy
Background: Information and communications technology can be used in telenursing to facilitate remote service delivery, thereby helping mitigate the general global nursing shortage as well as particular applications (eg, in geographically remote communities). Telenursing can thus bring services closer to end users, offering patient convenience and reduced hospitalization and health system costs, enabling more effective resource allocation. Objective: This study aims to examine the impact of patients’ education and telenursing follow-ups on self-care indicators among patients with type I and type II diabetes mellitus (DM). Methods: In phase I, a cross-sectional descriptive analysis was conducted to evaluate the self-care practices of 400 patients with DM at Kafr El Sheikh University Hospital in Egypt. In phase II, a pretest-posttest experiment was applied with a selected group of 100 patients purposively recruited from phase I due to their low self-care practice knowledge to ascertain the impacts of a 4-week intervention delivered via telenursing. They were reminded via telephone follow-up communication of the importance of adhering to recommendations on physical activity, nutritional intake, and the management of blood sugar (ie, insulin). Data collection was undertaken using a structured quantitative questionnaire, encompassing sociodemographic characteristics, medical symptoms and history, and knowledge of DM. Paired t test analysis was applied to study pre- and postintervention self-care behaviors. Results: Participants had a mean age of 49.7 (SD 11.5) years. More than one-third received their DM diagnosis over a decade previously (135/400, 33.8%) and were obese (147/400, 36.8%). Almost half (176/400, 44%) received insulin, and the majority had cardiac disease (231/400, 57.7%) and the DM symptom of elevated blood sugar levels while fasting (365/400, 91.3%). A relatively high score of DM knowledge was reported (255/400, 63.7%). Males exhibited significantly lower knowledge levels (102/200, 51%) compared to females (153/200, 76.5%; P<.001). The intervention was effective in improving knowledge of DM (t99=30.7, two-tailed; P<.001), self-care practices (t99=53.7, two-tailed; P<.001), and self-care skills (t99= 47, two-tailed; P<.001) among patients with DM. Conclusions: The emergent evidence suggests that patients’ education and telenursing follow-ups have the potential to improve self-care behavior in patients with DM. The delivery of frequent nursing reinforcement via telenursing enables improved self-management while contemporaneously reducing the need for patients to visit clinical settings (ie, improving patient condition and reducing net health system costs). The outcomes of this research underscore the need to integrate telenursing within conventional care for DM, and more research is needed to longitudinally assay its efficacy and sustainability over the long term and in different clinical and geographical contexts.