MINH-CHAU DINH

Dr. MINH-CHAU DINH

Institute of Mechatronics, Changwon National University
orcid

Research Focus & Metrics

Academic Career Length

15Years (2012-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 May 2021 in Energies
Verified
Journal Article
Open access
PDF file
Van Quan DaoVan Quan Dao
Van Quan Dao
MINH-CHAU DINHMINH-CHAU DINH
MINH-CHAU DINH
CKChang Soon Kim
Chang Soon Kim
MPMinwon Park
Minwon Park
CDChil-Hoon Doh
Chil-Hoon Doh
ZBZhiguo Bai
Zhiguo Bai
Currently, Lithium-ion batteries (LiB) are widely applied in energy storage devices in smart grids and electric vehicles. The state of charge (SOC) is an indication of the available battery capacity, and is one of the most important factors that should be monitored to optimize LiB’s performance and improve its lifetime. However, because the SOC relies on many nonlinear factors, it is difficult to estimate accurately. This paper presented the design of an effective SOC estimation method for a LiB pack Battery Management System (BMS) based on Kalman Filter (KF) and Artificial Neural Network (ANN). First, considering the configuration and specifications of the BMS and LiB pack, an ANN was constructed for the SOC estimation, and then the ANN was trained and tested using the Google TensorFlow open-source library. An SOC estimation model based on the extended KF (EKF) and a Thevenin battery model was developed. Then, we proposed a combined mode EKF-ANN that integrates the estimation of the EKF into the ANN. Both methods were evaluated through experiments conducted on a real LiB pack. As a result, the ANN and KF methods showed maximum errors of 2.6% and 2.8%, but the EKF-ANN method showed better performance with less than 1% error.

30 August 2022 in Energies
Verified
Journal Article
Open access
PDF file
CKChanghyun Kim
Changhyun Kim
MINH-CHAU DINHMINH-CHAU DINH
MINH-CHAU DINH
HSHae-Jin Sung
Hae-Jin Sung
kyong-hwan kimkyong-hwan kim
kyong-hwan kim
JCJeong-Ho Choi
Jeong-Ho Choi
MPMinwon Park
Minwon Park
Predicting the output power of wind generators is essential to improve grid flexibility, which is vulnerable to power supply variability and uncertainty. Digital twins can help predict the output of a wind turbine using a variety of environmental data generated by real-world systems. This paper dealt with the development of a physics-based output prediction model (P-bOPM) for a 10 MW floating offshore wind turbine (FOWT) for a digital twin. The wind power generator dealt with in this paper was modeled considering the NREL 5 MW standard wind turbine with a semi-submersible structure. A P-bOPM of a 10 MW FOWT for a digital twin was designed and simulated using ANSYS Twin Builder. By connecting the P-bOPM developed for the digital twin implementation with an external sensor through TCP/IP communication, it was possible to calculate the output of the wind turbine using real-time field data. As a result of evaluating the P-bOPM for various marine environments, it showed good accuracy. The digital twin equipped with the P-bOPM, which accurately reflects the variability of the offshore wind farm and can predict the output in real time, will be a great help in improving the flexibility of the power system in the future.

28 July 2021 in Energies
Verified
Journal Article
Open access
PDF file
TPThanh Dam Pham
Thanh Dam Pham
MINH-CHAU DINHMINH-CHAU DINH
MINH-CHAU DINH
HKHak-Man Kim
Hak-Man Kim
TNThai-Thanh Nguyen
Thai-Thanh Nguyen
Floating offshore wind has received more attention due to its advantage of access to incredible wind resources over deep waters. Modeling of floating offshore wind farms is essential to evaluate their impacts on the electric power system, in which the floating offshore wind turbine should be adequately modeled for real-time simulation studies. This study proposes a simplified floating offshore wind turbine model, which is applicable for the real-time simulation of large-scale floating offshore wind farms. Two types of floating wind turbines are evaluated in this paper: the semi-submersible and spar-buoy floating wind turbines. The effectiveness of the simplified turbine models is shown by a comparison study with the detailed FAST (Fatigue, Aerodynamics, Structures, and Turbulence) floating turbine model. A large-scale floating offshore wind farm including eighty units of simplified turbines is tested in parallel simulation and real-time software (OPAL-RT). The wake effects among turbines and the effect of wind speeds on ocean waves are also taken into account in the modeling of offshore wind farms. Validation results show sufficient accuracy of the simplified models compared to detailed FAST models. The real-time results of offshore wind farms show the feasibility of the proposed turbine models for the real-time model of large-scale offshore wind farms.

10 January 2022 in Energies
Verified
Journal Article
Open access
PDF file
JPJinJe Park
JinJe Park
CKChanghyun Kim
Changhyun Kim
MINH-CHAU DINHMINH-CHAU DINH
MINH-CHAU DINH
MPMinwon Park
Minwon Park
Renewable energy is being adopted worldwide, and the proportion of offshore wind turbines is increasing. Offshore wind turbines operate in harsh weather conditions, resulting in various failures and high maintenance costs. In this paper, a condition diagnosis model for condition monitoring of an offshore wind turbine has been developed. The generator, main bearing, pitch system, and yaw system were selected as components subject to the condition monitoring by considering the failure rate and downtime of the wind turbine. The condition diagnosis model works by comparing real-time and predictive operating data of the wind turbine, and about four years of Supervisory Control and Data Acquisition (SCADA) data from a 2 MW wind turbine was used to develop the model. A deep neural network and an artificial neural network were used as machine learning to predict the operational data in the condition diagnosis model, and a confusion matrix was used to measure the accuracy of the failure determination. As a result of the condition monitoring derived by inputting SCADA data to the designed system, it was possible to maintain the failure determination accuracy of more than 90%. The proposed condition monitoring system will be effectively utilized for the maintenance of wind turbines.

23 December 2022 in Energies
Verified
Journal Article
Open access
PDF file
JLJae-In Lee
Jae-In Lee
WJWoo-Hee Jeong
Woo-Hee Jeong
MINH-CHAU DINHMINH-CHAU DINH
MINH-CHAU DINH
IYIn-Keun Yu
In-Keun Yu
MPMinwon Park
Minwon Park
The application of cross-linked polyethylene (XLPE) cables to voltage sourced converter (VSC)-based high voltage direct current (HVDC) systems has already been technically verified and has become common, and thermoplastic (TP) is attracting attention as an insulation material for next-generation cables due to the recent development of material-related technologies. However, studies related to TP cables are mainly focused on improving material properties, and studies related to cable systems are insufficient. In this paper, XLPE and TP cables were designed for application to VSC-based HVDC systems, and major characteristics such as electric field distribution and thermal stability were compared and analyzed through overvoltage simulation. The insulation design method of HVDC cable was presented, and the design was performed using XLPE and TP insulation materials. The temperature and electric field profiles of the cables were also analyzed through a finite element method simulation. To analyze the performance of the designed cable, it was simulated with the PSCAD/EMTDC program. Based on the simulation results, the major characteristics of XLPE and TP cables were compared and analyzed. Results showed that in the case of TP cables, insulation properties were excellent, but thermal conductivity was relatively low; therefore, countermeasures are needed.

30 November 2021 in Energies
Verified
Journal Article
Open access
PDF file
JLJae-In Lee
Jae-In Lee
Van Quan DaoVan Quan Dao
Van Quan Dao
MINH-CHAU DINHMINH-CHAU DINH
MINH-CHAU DINH
SLSeok-Ju Lee
Seok-Ju Lee
CKChang Soon Kim
Chang Soon Kim
MPMinwon Park
Minwon Park
Recently, in order to overcome the difficulties of interrupting fault currents in multi-terminal direct current systems (MTDC), studies combining a saturated iron-core type superconducting current limiter (SFCL) and a direct current circuit breaker (DCCB) have been conducted. However, the effect of inductance change of the SI-SFCL on the interrupting time of the DCCB during fault has not been studied yet. In this paper, the interrupting time delay caused by the dynamic behavior of the inductance change during the fault current blocking process of the SI-SFCL combined with a DCCB was analyzed through experiments and a new fault detection method considering this phenomenon was proposed. After designing and manufacturing the laboratory-scale SI-SFCL and DCCB, a fault current interrupting test was performed and the inductance change pattern of the SI-SFCL was analyzed. Based on the analysis results, a new fault detection technique was proposed to alleviate the interruption time delay that occurs when applying the combined protection system to a MTDC, and its effectiveness was verified through a simulation. These results will be useful for planning protection coordination strategies when introducing a SI-SFCL in combination with a DCCB in actual MTDC systems.