Van Quan Dao

Dr. Van Quan Dao

Department of electrical engineering, Changwon National University
orcid

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 May 2021 in Energies
Verified
Journal Article
Open access
PDF file
Van Quan DaoVan Quan Dao
Van Quan Dao
MINH-CHAU DINHMINH-CHAU DINH
MINH-CHAU DINH
CKChang Soon Kim
Chang Soon Kim
MPMinwon Park
Minwon Park
CDChil-Hoon Doh
Chil-Hoon Doh
ZBZhiguo Bai
Zhiguo Bai
Currently, Lithium-ion batteries (LiB) are widely applied in energy storage devices in smart grids and electric vehicles. The state of charge (SOC) is an indication of the available battery capacity, and is one of the most important factors that should be monitored to optimize LiB’s performance and improve its lifetime. However, because the SOC relies on many nonlinear factors, it is difficult to estimate accurately. This paper presented the design of an effective SOC estimation method for a LiB pack Battery Management System (BMS) based on Kalman Filter (KF) and Artificial Neural Network (ANN). First, considering the configuration and specifications of the BMS and LiB pack, an ANN was constructed for the SOC estimation, and then the ANN was trained and tested using the Google TensorFlow open-source library. An SOC estimation model based on the extended KF (EKF) and a Thevenin battery model was developed. Then, we proposed a combined mode EKF-ANN that integrates the estimation of the EKF into the ANN. Both methods were evaluated through experiments conducted on a real LiB pack. As a result, the ANN and KF methods showed maximum errors of 2.6% and 2.8%, but the EKF-ANN method showed better performance with less than 1% error.

21 January 2020 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
Van Quan DaoVan Quan Dao
Van Quan Dao
JLJae-In Lee
Jae-In Lee
CKChang-Soon Kim
Chang-Soon Kim
MPMinwon Park
Minwon Park
A superconducting fault current limiter can significantly reduce the stress on the DC circuit breaker in DC power systems due to its inherent physical characteristics that can quickly limit the fault current. This paper presented the conceptual design of a saturated iron-core superconducting fault current limiter (SI-SFCL) for DC power systems. First, the electrical characteristics of the SI-SFCL were investigated. Then, a detailed design process and corresponding configuration of the SI-SFCL for a 15 kV, 3 kA DC power system were presented. A PSCAD/EMTDC simulation model was built to analyze the operating and fault current limiting characteristics of the SI-SFCL. To demonstrate the effectiveness of the conceptual design parameters and configuration, a lab-scale SI-SFCL for a 500 V, 50 A DC power system was designed in detail. The fault current limiting capability of the lab-scale SI-SFCL was confirmed by the 3D finite element method. As a result, the lab-scale SI-SFCL has a high current limiting capability, which can reduce the magnitude of the fault current by up to 75%. This study results will be effectively applied to a large-scale SI-SFCL for HVDC power systems.

30 November 2021 in Energies
Verified
Journal Article
Open access
PDF file
JLJae-In Lee
Jae-In Lee
Van Quan DaoVan Quan Dao
Van Quan Dao
MINH-CHAU DINHMINH-CHAU DINH
MINH-CHAU DINH
SLSeok-Ju Lee
Seok-Ju Lee
CKChang Soon Kim
Chang Soon Kim
MPMinwon Park
Minwon Park
Recently, in order to overcome the difficulties of interrupting fault currents in multi-terminal direct current systems (MTDC), studies combining a saturated iron-core type superconducting current limiter (SFCL) and a direct current circuit breaker (DCCB) have been conducted. However, the effect of inductance change of the SI-SFCL on the interrupting time of the DCCB during fault has not been studied yet. In this paper, the interrupting time delay caused by the dynamic behavior of the inductance change during the fault current blocking process of the SI-SFCL combined with a DCCB was analyzed through experiments and a new fault detection method considering this phenomenon was proposed. After designing and manufacturing the laboratory-scale SI-SFCL and DCCB, a fault current interrupting test was performed and the inductance change pattern of the SI-SFCL was analyzed. Based on the analysis results, a new fault detection technique was proposed to alleviate the interruption time delay that occurs when applying the combined protection system to a MTDC, and its effectiveness was verified through a simulation. These results will be useful for planning protection coordination strategies when introducing a SI-SFCL in combination with a DCCB in actual MTDC systems.

20 November 2020 in Energies
Verified
Journal Article
Open access
PDF file
Van Quan DaoVan Quan Dao
Van Quan Dao
JLJae-In Lee
Jae-In Lee
CKChang Soon Kim
Chang Soon Kim
MPMinwon Park
Minwon Park
UMUmberto Melaccio
Umberto Melaccio
A saturated iron-core superconducting fault current limiter (SI-SFCL) can significantly limit the magnitude of the fault current and reduce the stress on circuit breakers in direct current (DC) power systems. The SI-SFCL consists of three main parts: one magnetic iron-core, one normal conductive primary coil (CPC), and one superconducting secondary coil (SSC). This paper deals with the design options for the coil system of the SI-SFCL and confirms their operating characteristics through a physical experiment. The electromagnetic characteristics and operational features of the SI-SFCL was analyzed by a 3D finite element method simulation model. The design of the SSC was based on shape, wire types, required fault current limit and protection aspects. In the CPC, the bobbin was designed based on material selection, cost, structural design, and the effects of the SI-SFCL on the fault current limit. Based on these simulation results, a laboratory-scale SI-SFCL was developed, specifically fabricated to operate on a 500 V, 50 A direct current (DC) power system. In the experiment, the operating characteristics of each coil were analyzed, and the fault current limit of the SI-SFCL according to the operating currents of the SSC and bobbin design of the CPC were confirmed. Finally, the cost analysis of the SI-SFCL with the proposed design options of the coil system was implemented. The results obtained through this study can be effectively used to large-scale SI-SFCL development studies for high-voltage direct current (HVDC) power systems.

30 March 2021 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
Van Quan DaoVan Quan Dao
Van Quan Dao
JLJaeIn Lee
JaeIn Lee
CKChang-Soon Kim
Chang-Soon Kim
MPMinwon Park
Minwon Park
Several recent studies have proposed a conceptual design of a saturated iron-core superconducting fault current limiter (SI-SFCL) for DC power systems, but experimental studies to verify its operating characteristics and performance have not yet been conducted. In this paper, a laboratory-scale SI-SFCL was designed and tested to operate in a 500 V, 50 A DC power system. First, the detailed configuration, specifications, and hardware manufacturing contents of the SI-SFCL were presented, and then an experimental circuit was developed and installed for the performance test of the SI-SFCL in normal operation and failure conditions. A 3D finite element method model was constructed to compare the simulation results and experimental results for the operating function of the SI-SFCL. Without the SI-SFCL, the maximum fault current level was 500 A, as a result, the SI-SFCL has a large current limit function, which can reduce the magnitude of the fault current up to the design target value of 73.6%. The results obtained in this study can be effectively applied to large-scale SI-SFCL development studies for HVDC power systems.

4 February 2019 in IEEE Transactions on Applied Superconductivity
Verified
Journal Article
Closed access
Van Quan DaoVan Quan Dao
Van Quan Dao
CKChang-Soon Kim
Chang-Soon Kim
CLChankyeong Lee
Chankyeong Lee
JCJongho Choi
Jongho Choi
MPMinwon Park
Minwon Park
IYIn-Keun Yu
In-Keun Yu
Recently, certain superconducting wires, such as second-generation high-temperature superconducting (2G HTS) and low-temperature superconducting magnesium diboride (MgB2) wires, have been used in DC induction heaters. Therefore, it is necessary to analyze and compare which wire type is better for the magnet design of a superconducting DC induction heater. This paper presents the design process and comparative analysis results of 3 T superconducting magnets for a 300 kW-class DC induction heater using 2G HTS Yttrium Barium Copper Oxide (YBCO) and MgB2 wires. The specifications of the YBCO wire and two types of MgB2 wires were firstly investigated. The magnets were then designed so that the maximum magnetic flux density was 3 T, and the magnetic field distributions were analyzed using a 3D finite element method program. Finally, the magnet designs were compared in terms of size, magnetic flux density, operating current and temperature, winding method, required length, and wire cost. This study result will be effectively applied to a commercial 300 kW class superconducting DC induction heater.