Mykhailo Fryz

Dr. Mykhailo Fryz

orcid

Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
14 November 2023
Verified
Book Chapter
Closed access
PDF file
VBVitalii Babak
Vitalii Babak
Artur ZaporozhetsArtur Zaporozhets
Artur Zaporozhets
Svitlana KovtunSvitlana Kovtun
Svitlana Kovtun
YKYurii Kuts
Yurii Kuts
MFMykhailo Fryz
Mykhailo Fryz
LSLeonid Scherbak
Leonid Scherbak

1 May 2017
Verified
Conference Paper
Closed access
MFMykhailo Fryz
Mykhailo Fryz
In the paper a new mathematical model of electroencephalographic (EEG) signal has been justified in the form of conditional linear random process (CLRP). The model has been derived from the biophysical nature of brain electrical activity. Random coefficient autoregressive (RCA) model (as a member of the class of discrete-time CLRP) has been applied for EEG signal processing. Using the special statistical test, RCA model has been shown to be more suitable for given EEG data than the autoregressive one with constant coefficients, especially for heteroscedastic EEG from epileptic patients.

1 September 2009
Verified
Conference Paper
Closed access
MFMykhailo Fryz
Mykhailo Fryz
Using a characteristic function method the mixing property and ergodicity of strictly stationary continuous-time linear random process driven by process with independent increments have been proven.


5 May 2024 in System Research in Energy
Verified
Journal Article
Open access
PDF file
Svitlana KovtunSvitlana Kovtun
Svitlana Kovtun
YKYurii Kuts
Yurii Kuts
VMVolodymyr Malko
Volodymyr Malko
MFMykhailo Fryz
Mykhailo Fryz
LSLeonid Shcherbak
Leonid Shcherbak
VKVolodymyr Kuts
Volodymyr Kuts
During the operation of power grids, abnormal modes occur that lead to a decrease or increase in the grid voltage beyond permissible values, the appearance of high-frequency noise components and grid signal fading’s, which fading’s the power quality and can lead to the failure of electrical equipment. This requires constant monitoring of power quality indicators. The methods of measuring power quality indicators have been examined and analyzed in the article, their advantages and limitations have been considered, and the inefficiency of using the Fourier transform for estimating of power quality indicators in time domain has been justified. The application of Hilbert transform has been suggested for monitoring the indicators of power quality in general-purpose grids, which include measuring the duration and magnitude of voltage dips, the duration of voltage fading, localization and determination of the duration of high-frequency noise interference in the power grid, determination of phase shift during voltage dip. A simulation of the process of determining the indicators of power quality in time domain and the time intervals during which these indicators exceed the established limits has been performed, which confirmed the effectiveness of using the Hilbert transform in the systems of their monitoring. Keywords: general purpose power grid, power quality indicators, Hilbert transform.

22 September 2024
Verified
Book Chapter
Closed access
PDF file
VBVitalii Babak
Vitalii Babak
Artur ZaporozhetsArtur Zaporozhets
Artur Zaporozhets
Svitlana KovtunSvitlana Kovtun
Svitlana Kovtun
YKYurii Kuts
Yurii Kuts
MFMykhailo Fryz
Mykhailo Fryz
LSLeonid Scherbak
Leonid Scherbak