Volodymyr Malko

Volodymyr Malko

Auto-generated profile, based on publicly available information

Volodymyr Malko

General Energy Institute of NAS of Ukraine

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 December 2023 in Transactions on Aerospace Research
Verified
Journal Article
Open access
PDF file
ILIuliia Lysenko
Iuliia Lysenko
YKYurii Kuts
Yurii Kuts
VPValentyn Petryk
Valentyn Petryk
VMVolodymyr Malko
Volodymyr Malko
AMAndrii Melnyk
Andrii Melnyk
Aircraft part diagnostics are crucial during both production and maintenance, with eddy current nondestructive testing (ECNDT) being the method of choice due to its cost-effectiveness, informativeness, productivity, and reliability. ECNDT excels regardless of surface condition or coatings. It’s employed for diagnosing various aircraft components, necessitating diverse transducer types, excitation modes, and advanced signal processing. To improve ECNDT, this article explores integrating harmonic and impulse excitation modes in a single tool to enhance informativeness. Building upon a wireless eddy current system, the authors propose a comprehensive method for processing and displaying information suitable for object condition monitoring systems. The system includes automated transducer mode control and experimental data processing algorithms. The constant expansion of tested objects and new materials underscores the need to enhance the theoretical foundations of eddy current non-destructive testing, refine signal processing techniques, and identify informative signs. This demands the development of new automated ECNDT tools, and this article offers a promising avenue for improvement. The results include model and experimental tests of system components, showcasing the potential of this approach to enhance ECNDT effectiveness, automation, and informativeness in the realm of aircraft part diagnostics.

5 May 2024 in System Research in Energy
Verified
Journal Article
Open access
PDF file
Svitlana KovtunSvitlana Kovtun
Svitlana Kovtun
YKYurii Kuts
Yurii Kuts
VMVolodymyr Malko
Volodymyr Malko
MFMykhailo Fryz
Mykhailo Fryz
LSLeonid Shcherbak
Leonid Shcherbak
VKVolodymyr Kuts
Volodymyr Kuts
During the operation of power grids, abnormal modes occur that lead to a decrease or increase in the grid voltage beyond permissible values, the appearance of high-frequency noise components and grid signal fading’s, which fading’s the power quality and can lead to the failure of electrical equipment. This requires constant monitoring of power quality indicators. The methods of measuring power quality indicators have been examined and analyzed in the article, their advantages and limitations have been considered, and the inefficiency of using the Fourier transform for estimating of power quality indicators in time domain has been justified. The application of Hilbert transform has been suggested for monitoring the indicators of power quality in general-purpose grids, which include measuring the duration and magnitude of voltage dips, the duration of voltage fading, localization and determination of the duration of high-frequency noise interference in the power grid, determination of phase shift during voltage dip. A simulation of the process of determining the indicators of power quality in time domain and the time intervals during which these indicators exceed the established limits has been performed, which confirmed the effectiveness of using the Hilbert transform in the systems of their monitoring. Keywords: general purpose power grid, power quality indicators, Hilbert transform.


30 June 2023 in Bulletin of Kyiv Polytechnic Institute. Series Instrument Making
Verified
Journal Article
Open access
PDF file
VMVolodymyr Malko
Volodymyr Malko
YKYurii Kuts
Yurii Kuts
ILIuliia Lysenko
Iuliia Lysenko
LSLeonid Scherbak
Leonid Scherbak
ЮКЮрій Куц
Юрій Куц
ЮЛЮлія Лисенко
Юлія Лисенко
The article is devoted to the issue of improving the coordinate registration of information in means of automated non-destructive testing. Existing systems of non-contact registration of spatial position sensors of non-destructive testing are mostly focused on the use of signal fields of different physical nature, for example, acoustic or optical, which are created around the position of these sensors and amplitude methods of signal processing. These methods do not provide the necessary accuracy of determining the coordinates in the case of using small-aperture sensors of non-destructive testing. The basis of the proposed technical solution is the trilateration method. The distance between the emitter of ultrasonic vibration, which is structurally connected to the sensor, and the two receivers is determined by the phase method. This method provides increased accuracy in determining the coordinates of the sensor. Eliminating the ambiguity of phase measurements is based on the combination of the multi-frequency method and the numerical system of residual classes. This makes it possible to minimize the probability of incorrect resolution of the ambiguity of the results of phase distance measurements and to ensure high accuracy of coordinate determination (with an absolute error of the order of mm). The idea of the method and the main calculation formulas that make it possible to determine the modules of the numerical system of residual classes and the values of the operating frequencies of ultrasonic oscillations are presented. Matching the discretes for determining the phase shifts of signals with the modules of the numerical system of residual classes at different operating frequencies makes it possible to reduce the resolution of the ambiguity of the results of phase measurements to the task of restoring integers in the positional counting system from their representation by residuals in the numerical system of residual classes. The mechanism of occurrence of gross errors in the recovery of whole numbers is considered. An algorithm for eliminating this error is proposed. In general, the correctness of the algorithm for determining the sensor coordinates is confirmed by the simulation results. The considered method of two-coordinate information registration can be used both in the development of new automated means of non-destructive testing, and for the improvement of existing ones, which involve a manual method of scanning the surface of testing objects.

18 September 2026 in System Research in Energy
Verified
Journal Article
Open access
PDF file
ODOleg Dekusha
Oleg Dekusha
Svitlana KovtunSvitlana Kovtun
Svitlana Kovtun
Artur ZaporozhetsArtur Zaporozhets
Artur Zaporozhets
VTValentyn Tsapenko
Valentyn Tsapenko
VMVolodymyr Malko
Volodymyr Malko
Continuous monitoring of atmospheric air quality in the vicinity of energy facilities ‒ thermal power plants (TPPs) and combined heat and power plants (CHPPs) ‒ is a critically important task for ensuring environmental safety and compliance with regulatory requirements. Such facilities are major stationary sources of pollutant emissions, including nitrogen oxides, sulfur dioxide, carbon monoxide, and fine particulate matter (PM2.5, PM10), whose concentrations directly affect public health. This paper addresses the development of a hybrid multisensor system architecture for atmospheric air pollution monitoring in the vicinity of energy facilities. A general review and comparative analysis of multisensor monitoring system architectures ‒ local, distributed (centralized and decentralized), and hybrid ‒ have been conducted. The characteristic features, advantages, and limitations of each system type are identified, and the optimal areas of their application are determined. Based on the review results, a hybrid monitoring system architecture has been proposed, combining the advantages of local and distributed approaches on the principles of distributed data acquisition with integrated centralized processing, ensuring scalability and effective air quality control within the zone of influence of energy infrastructure. The structure of a multisensor system module based on the ESP8266EX microcontroller has been developed, incorporating a comprehensive set of low-cost sensors for simultaneous measurement of PM2.5, PM10, CO, NO₂, NH₃, SO₂, O₃, CH₂O, and CO₂ concentrations, as well as temperature, relative humidity, and atmospheric pressure. The module includes dedicated functional units for geolocation, data storage and backup, status indication, and secure Wi-Fi communication. The proposed structure ensures energy efficiency, scalability, and the capability of integrating artificial intelligence algorithms for pollution dynamics forecasting. Keywords: multisensor monitoring system, atmospheric air pollution, energy facilities, hybrid architecture, IoT, low-cost sensors, ESP8266.

1 January 2026 in Measuring Equipment and Metrology
Verified
Journal Article
Closed access
VMVolodymyr Malko
Volodymyr Malko
YKYurii Kuts
Yurii Kuts
The fundamental frequency of the power supply is a key characteristic of power quality in general-purpose power grids. Deviations of the fundamental frequency from the standard values occur due to an imbalance between power generation and consumption, malfunctions of power plants or power lines. Instability of the fundamental frequency of the power supply voltage leads to a decrease in the efficiency of motors, reduced lifetime of electrical equipment, etc. In power quality monitoring systems, the result of the fundamental frequency measurement according to current standards must be presented as a measured value together with an accuracy indicator in the form of uncertainty. This characteristic depends on various influencing factors, including the measurement method. One of the effective methods for measuring the fundamental frequency is based on the analysis of the phase characteristics of the power supply voltage, which is determined using the Hilbert transform. The purpose of the article is to estimate the uncertainty of measuring the fundamental frequency of the power supply voltage using the phase method, which involves determining the phase characteristic of the voltage using the Hilbert transform. For uncertainty estimates, an Ishikawa diagram was created and an uncertainty budget was justified. To reduce uncertainty in estimating the fundamental frequency, sliding averaging of the phase accumulation was proposed. Simulation experiments showed that this phase method makes it possible to determine the fundamental frequency with a combined standard uncertainty of ~7.5 mHz and a corresponding expanded uncertainty of ~ ±15 mHz (k = 2), which is quite acceptable for power quality monitoring