Richard G.P. Lopata

Prof. Dr. Richard G.P. Lopata

orcid

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 May 2009 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
RLRichard G.P. Lopata
Richard G.P. Lopata
MNMaartje M. Nillesen
Maartje M. Nillesen
HHHendrik H.G. Hansen
Hendrik H.G. Hansen
IGInge H. Gerrits
Inge H. Gerrits
JTJohan M. Thijssen
Johan M. Thijssen
CKChris L. de Korte
Chris L. de Korte

1 April 2007 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
HRHermine Ribbers
Hermine Ribbers
RLRichard G.P. Lopata
Richard G.P. Lopata
SHSuzanne Holewijn
Suzanne Holewijn
GPGerard Pasterkamp
Gerard Pasterkamp
JBJan D. Blankensteijn
Jan D. Blankensteijn
CKChris L. de Korte
Chris L. de Korte

6 January 2009 in IEEE Transactions on Medical Imaging
Verified
Journal Article
Closed access
HHHendrik H. G. Hansen
Hendrik H. G. Hansen
RLRichard G.P. Lopata
Richard G.P. Lopata
CKChris L. de Korte
Chris L. de Korte
Stroke and myocardial infarction are initiated by rupturing vulnerable atherosclerotic plaques. With noninvasive ultrasound elastography, these plaques might be detected in carotid arteries. However, since the ultrasound beam is generally not aligned with the radial direction in which the artery pulsates, radial and circumferential strains need to be derived from axial and lateral data. Conventional techniques to perform this conversion have the disadvantage that lateral strain is required. Since the lateral strain has relatively poor accuracy, the quality of the radial and circumferential strains is reduced. In this study, the radial and circumferential strain estimates are improved by combining axial strain data acquired at multiple insonification angles. Adaptive techniques to correct for grating lobe interference and other artifacts that occur when performing beam steering at large angles are introduced. Acquisitions at multiple angles are performed with a beam steered linear array. For each beam steered angle, there are two spatially restricted regions of the circular vessel cross section where the axial strain is closely aligned with the radial strain and two spatially restricted regions (different from the radial strain regions) where the axial strain is closely aligned with the circumferential strain. These segments with high quality strain estimates are compounded to form radial or circumferential strain images. Compound radial and circumferential strain images were constructed for a homogeneous vessel phantom with a concentric lumen subjected to different intraluminal pressures. Comparison of the elastographic signal-to-noise ratio (SNRe) and contrast-to-noise ratio ( CNRe) revealed that compounding increases the image quality considerably compared to images from 0deg information only. SNRe and CNRe increase up to 2.7 and 6.6 dB, respectively. The highest image quality was achieved by projecting axial data, completed with a small segment determined by either principal component analysis or by application of a rotation matrix.

17 May 2010 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
PDF file
HHH H G Hansen
H H G Hansen
RLRichard G.P. Lopata
Richard G.P. Lopata
TIT Idzenga
T Idzenga
CKC L de Korte
C L de Korte
Ultrasound strain imaging is used to measure local tissue deformations. Usually, only strains along the ultrasound beam are estimated, because those estimates are most precise, due to the availability of phase information. For estimating strain in other directions we propose to steer the ultrasound beam at an angle, which allows estimating different projections of the 2D strain tensor, while phase information remains available. This study investigates beam steering at maximally three different angles to determine the full 2D strain tensor. The method was tested on simulated and experimental data of an inclusion phantom and a vessel phantom. The combination of data from a non-steered acquisition and acquisitions at a large positive and an equally large but negative steering angle enabled the most precise estimation of the strain components. The method outperforms conventional methods that do not use beam steering.

1 September 2010 in Journal of Applied Physiology
Verified
Journal Article
Closed access
RLRichard G.P. Lopata
Richard G.P. Lopata
Johannes Van DijkJohannes Van Dijk
Johannes Van Dijk
SPSigrid Pillen
Sigrid Pillen
MNMaartje M. Nillesen
Maartje M. Nillesen
HMHuub Maas
Huub Maas
CKChris L. de Korte
Chris L. de Korte
In this study, a multidimensional strain estimation method using biplane ultrasound is presented to assess local relative deformation (i.e., local strain) in three orthogonal directions in skeletal muscles during induced and voluntary contractions. The method was tested in the musculus biceps brachii of five healthy subjects for three different types of muscle contraction: 1) excitation of the muscle with a single electrical pulse via the musculocutaneous nerve, resulting in a so-called “twitch” contraction; 2) a train of five pulses at 10 Hz and 20 Hz, respectively, to obtain a submaximum tetanic contraction; and 3) voluntary contractions at 30, 60, and 100% of maximum contraction force. Results show that biplane ultrasound strain imaging is feasible. The method yielded adequate performance using the radio frequency data in tracking the tissue motion and enabled the measurement of local deformation in both the vertical direction (orthogonal to the arm) and in the horizontal directions (parallel and perpendicular to direction of the arm) in two orthogonal cross sections of the muscle. The twitch experiments appeared to be reproducible in all three directions, and high strains in vertical (25 to 30%) and horizontal (−20% to −10%) directions were measured. Visual inspection of both the ultrasound data, as well as the strain data, revealed a relaxation that was significantly slower than the force decay. The pulse train experiments nicely illustrated the performance of our technique: 1) similar patterns of force and strain waveforms were found; and 2) each stimulation frequency yielded a different strain pattern, e.g., peak vertical strain was 40% during 10-Hz stimulation and 60% during 20-Hz stimulation. The voluntary contraction patterns were found to be both practically feasible and reproducible, which will enable muscles and more natural contraction patterns to be examined without the need of electrical stimulation.

1 September 2011 in Ultrasound in Medicine & Biology
Verified
Journal Article
Closed access
RLRichard G.P. Lopata
Richard G.P. Lopata
MNMaartje M. Nillesen
Maartje M. Nillesen
JTJohan M. Thijssen
Johan M. Thijssen
LKL. Kapusta
L. Kapusta
CKChris L. de Korte
Chris L. de Korte