Joshua Roberti

Joshua Roberti

orcid

Research Focus & Metrics

Academic Career Length

13Years (2014-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
6 February 2017 in International Journal of Climatology
Verified
Journal Article
Open access
PDF file
CDChristopher Daly
Christopher Daly
MSMelissa E. Slater
Melissa E. Slater
JRJoshua Roberti
Joshua Roberti
SLStephanie H. Laseter
Stephanie H. Laseter
LSLloyd W. Swift
Lloyd W. Swift
A 69‐station, densely spaced rain gauge network was maintained over the period 1951–1958 in the Coweeta Hydrologic Laboratory, located in the southern Appalachians in western North Carolina, USA. This unique dataset was used to develop the first digital seasonal and annual precipitation maps for the Coweeta basin, using elevation regression functions and residual interpolation. It was found that a 10‐m elevation grid filtered to an approximately 7‐km effective wavelength explained the most variance in precipitation (R2 = 0.82–0.95). A ‘dump zone’ of locally high precipitation a short distance downwind from the mountain crest marking the southern border of the basin was the main feature that was not explained well by the precipitation–elevation relationship.These data and maps provided a rare ‘ground‐truth’ for estimating uncertainty in the national‐scale Parameter‐elevation Relationships on Independent Slopes Model (PRISM) precipitation grids for this location and time period. Differences between PRISM and ground‐truth were compared with uncertainty estimates produced by the PRISM model and cross‐validation errors. Potential sources of uncertainty in the national PRISM grids were evaluated, including the effects of coarse grid resolution, limited station data, and imprecise station locations.The PRISM national grids matched closely (within 5%) with the Coweeta dataset. The PRISM regression prediction interval, which includes the influence of stations in an area of tens of kilometres around a given location, overestimated the local error at Coweeta (12–20%). Offsetting biases and generally low error rates made it difficult to isolate major sources of uncertainty in the PRISM grids, but station density and selection, and mislocation of stations were identified as likely sources of error. The methods used in this study can be repeated in other areas where high‐density data exist to gain a more comprehensive picture of the uncertainties in national‐level datasets, and can be used in network optimization exercises.

7 February 2017 in Ecosphere
Verified
Journal Article
Open access
PDF file
JCJanae Csavina
Janae Csavina
JRJoshua Roberti
Joshua Roberti
JTJeffrey R. Taylor
Jeffrey R. Taylor
HLHenry Loescher
Henry Loescher
Describing the quality of measurements is necessary to understand the level of confidence in any observation. Accuracy, precision, trueness, repeatability, reproducibility, and uncertainty are all used to describe quality of measurement, but the terms are inconsistently defined and measured and thus easily misunderstood. One purpose of quality parameters is for the comparison of observations, but when dissimilar methods for estimating quality terms are utilized, a comparison is misrepresented. A standardized approach to estimating uncertainty provides a basis for meeting measurement requirements and providing a level of confidence for observations. Here, we show the approach used by the National Ecological Observatory Network to estimate uncertainty of the calibration processes and measurements illustrated with an example of uncertainty assessment on a temperature sensor. Detailing the approach for uncertainty assessment provides the transparency necessary for network science and allows for the approach to be adopted in the scientific community. Reporting uncertainty with all measurements needs to become consistent and commonplace across disciplines.

31 July 2022 in Methods in Ecology and Evolution
Verified
Journal Article
Open access
CSCove Sturtevant
Cove Sturtevant
EDElizabeth DeRego
Elizabeth DeRego
SMStefan Metzger
Stefan Metzger
EAEdward Ayres
Edward Ayres
DADan Allen
Dan Allen
MSMichael SanClements
Michael SanClements
A quality management system is critical for ensuring that the data and services provided by an organization meet the needs of its mission. With a mission to collect long‐term open‐access ecological data to better understand how US ecosystems are changing, the National Ecological Observatory Network (NEON) is a highly standardized measurement network distributed across the United States and Puerto Rico collecting data on the biosphere and its interfaces with the pedosphere, hydrosphere and atmosphere. In order to achieve high‐quality, comparable data across the network, a quality management system was developed by applying the seven ISO 9001:2015 principles of quality management:customer focus,leadership, engagement of people, process approach, improvement, evidence‐based decision makingandrelationship management. The resultant system is integrated throughout NEON's organizational structure with an approach that connects people and operational processes throughout the data life cycle (process approach). We describe the system with respect to sensor data (automated measurements), demonstrating its effectiveness through examples, lessons learned and a continuous history of improvement towards quality goals, including a doubling of data quality in NEON's meteorological and soil datasets since 2015 and substantial gains in other sensor datasets. Owing to a focus on quality management principles and particularly the interconnectedness of human and information systems, NEON's quality management system can serve as a model for networks with a variety of organizational structures and sizes.

1 January 2014 in PLOS ONE
Verified
Journal Article
Open access
PDF file
JRJoshua Roberti
Joshua Roberti
MSMichael D. SanClements
Michael D. SanClements
HLHenry W. Loescher
Henry W. Loescher
EAEdward Ayres
Edward Ayres
Even though fine-root turnover is a highly studied topic, it is often poorly understood as a result of uncertainties inherent in its sampling, e.g., quantifying spatial and temporal variability. While many methods exist to quantify fine-root turnover, use of minirhizotrons has increased over the last two decades, making sensor errors another source of uncertainty. Currently, no standardized methodology exists to test and compare minirhizotron camera capability, imagery, and performance. This paper presents a reproducible, laboratory-based method by which minirhizotron cameras can be tested and validated in a traceable manner. The performance of camera characteristics was identified and test criteria were developed: we quantified the precision of camera location for successive images, estimated the trueness and precision of each camera's ability to quantify root diameter and root color, and also assessed the influence of heat dissipation introduced by the minirhizotron cameras and electrical components. We report detailed and defensible metrology analyses that examine the performance of two commercially available minirhizotron cameras. These cameras performed differently with regard to the various test criteria and uncertainty analyses. We recommend a defensible metrology approach to quantify the performance of minirhizotron camera characteristics and determine sensor-related measurement uncertainties prior to field use. This approach is also extensible to other digital imagery technologies. In turn, these approaches facilitate a greater understanding of measurement uncertainties (signal-to-noise ratio) inherent in the camera performance and allow such uncertainties to be quantified and mitigated so that estimates of fine-root turnover can be more confidently quantified.

29 October 2026 in Remote Sensing
Verified
Journal Article
Open access
PDF file
David Joseph DurdenDavid Joseph Durden
David Joseph Durden
TGTristan Goulden
Tristan Goulden
MSMichael SanClements
Michael SanClements
CHCedric Hagen
Cedric Hagen
MWMichael Dean Wussow
Michael Dean Wussow
JRJoshua Roberti
Joshua Roberti
This study evaluates the accuracy and usability of two low-cost uncrewed aerial system (UAS) multispectral sensors—MicaSense RedEdge-M and SlantRange 3p—using a dual-scale comparison framework. Calibrated 3% and 48% reflectance tarps and Analytical Spectral Device (ASD) field spectrometry were used for point-scale absolute validation. The NEON imaging spectrometer (NIS), a well-calibrated airborne hyperspectral sensor, was utilized for a field-scale comparison by spectrally resampling the hyperspectral data to align with the multispectral bands and performing spatial co-registration and aggregation of the multispectral data to a common 1 m grid. Over the 48% tarp, MicaSense Near-infrared (NIR) reflectance was 7.2% below the ASD reference while SlantRange NIR was 7.9% lower, validating previous studies that have observed the underestimation of the NIR band with UAS multispectral sensors. Both sensors overestimated the 3% tarp across all bands when compared to the ASD measurements. Field-scale regressions yielded R2 values above 0.90 for most bands, while NIR slopes were 0.74 for MicaSense and 0.72 for SlantRange. Consistent with these trends, the largest radiometric errors occurred in the NIR region, where both sensors increasingly underestimated high-reflectance surfaces relative to NIS. Median Normalized Difference Vegetation Index (NDVI) differences relative to NIS were −0.027 and −0.064, and these became more negative with an increasing NIS NDVI. Edge buffering reduced MicaSense bias, whereas the SlantRange showed limited edge effects. These results demonstrate that low-cost UAS multispectral imagery can support ecological applications when calibration, reflectance range, view geometry, and ecosystem-specific validation requirements are explicitly considered.

1 July 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
David Joseph DurdenDavid Joseph Durden
David Joseph Durden
TGTristan Goulden
Tristan Goulden
MSMichael SanClements
Michael SanClements
CHCedric Hagen
Cedric Hagen
MWMichael Dean Wussow
Michael Dean Wussow
JRJoshua Roberti
Joshua Roberti
This study evaluates the accuracy and usability of two low-cost unmanned aerial system (UAS) multispectral sensors—MicaSense RedEdge and SlantRange 3p—by comparing their reflectance measurements and NDVI to those of the NEON Imaging Spectrometer (NIS), a well-calibrated airborne hyperspectral sensor. Field validation was conducted using calibrated reflectance tarps, and spectrally resampled NIS data served as a reference standard. Reflectance comparisons showed both sensors performed well across most land cover types but exhibited systematic biases that prevented statistical equivalence in most bands. The MicaSense sensor generally overestimated reflectance, while the SlantRange sensor underestimated it, particularly in the Green and NIR bands. These biases propa-gated into NDVI calculations, where both UAS sensors reported lower NDVI values than the NIS, with SlantRange showing a larger negative bias. Despite the lower NDVI values and artifacts, including BRDF effects at image edges and background noise over dark sur-faces, the results support the viability of UAS-based multispectral sensing for ecological applications requiring moderate to high accuracy. The study also highlights the critical importance of radiometric calibration and sensor-specific limitations in reflectance range. This comparison framework provides a foundation for broader cross-platform validation efforts and helps inform best practices for ecological remote sensing using low-cost UAS systems.