Conventional typodonts for preclinical operative dentistry are idealised and lack the variability and tactile feedback of natural teeth; virtual-reality and haptic simulators remain costly for large cohorts. This study developed a reproducible, low-cost digital workflow for patient-specific, multi-material 3D-printed dental simulators and evaluated the models from a learner’s perspective. Intraoral and CBCT data from a single de-identified case were co-registered to a Virtual Patient. A modular tooth-socket architecture with trans-apical screw retention allowed repeatable individual tooth replacement; each tooth combined a variable-thickness enamel shell over a dentin core with multi-material carious lesions. Two fabrication routes (MSLA and PolyJet) and an adopted hybrid route (MSLA base, PolyJet teeth) were compared for cost, time and fidelity. The hybrid produced complete bimaxillary models at low consumable cost while preserving the source occlusion and contacts. Fifty dental students evaluated a PolyJet specimen hands-on: didactic utility scored highest (4.32 ± 0.65 on 1–5) and visual realism exceeded tactile realism (p < 0.001); 94% rated it at least comparable to a natural extracted tooth and 62% preferred it, while perceived hardness remained the main limitation. The workflow enables scalable in-house production of patient-specific simulators, with tactile realism the priority for material development.
Purpose: Haptic and mixed-reality (MR) simulation technologies are increasingly used in preclinical dental education to support psychomotor skill acquisition and to reduce early patient exposure. This technical feasibility study aimed to develop a patient-specific digital twin patient model integrated into an MR haptic-based dental simulator and to explore dental students’ perceptions of it through an exploratory post-workshop survey. Materials and Methods: A digital twin patient model was created by integrating intraoral, facial, and cone-beam computed tomography (CBCT) datasets, and was implemented within the SIMtoCARE Dente haptic-based dental simulator (SIMtoCARE B.V., Vreeland, The Netherlands). In this single-centre pilot study, students completed a structured questionnaire assessing usability, perceived fidelity, and curricular relevance on the same day, following a single faculty-led workshop. Of the 50 students who attended, 41 completed the questionnaire (response rate: 82%). Results: The proposed workflow enabled the creation and implementation of the digital twin patient model. Students reported high acceptance and perceived educational value, with 92.7% supporting curricular integration. Prior exposure to haptic systems did not differ across demographic groups. Fourth-year respondents showed significantly higher agreement with the item on complementarity with conventional training. Conclusions: The digital twin patient model was positively perceived by dental students in this single-centre pilot study. These findings reflect immediate self-reported perceptions and require validation in larger, comparative and longitudinal studies.