Lucian Toma Ciocan

Prof. Dr. Lucian Toma Ciocan

Dental Prosthesis Technology, Carol Davila University of Medicine and Pharmacy, Bucharest, Bucureşti, Romania
orcid

Research Focus & Metrics

Academic Career Length

17Years (2010-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
8 January 2020 in Materials
Verified
Journal Article
Open access
PDF file
Andreea Madalina PandeleAndreea Madalina Pandele
Andreea Madalina Pandele
ACAndreea Constantinescu
Andreea Constantinescu
IRIonuţ Cristian Radu
Ionuţ Cristian Radu
Florin MiculescuFlorin Miculescu
Florin Miculescu
Stefan Ioan VoicuStefan Ioan Voicu
Stefan Ioan Voicu
Lucian Toma CiocanLucian Toma Ciocan
Lucian Toma Ciocan
This article presents a facile synthesis method used to obtain new composite films based on polylactic acid and micro-structured hydroxyapatite particles. The composite films were synthesized starting from a polymeric solution in chloroform (12 wt.%) in which various concentrations of hydroxyapatite (1, 2, and 4 wt.% related to polymer) were homogenously dispersed using ultrasonication followed by solvent evaporation. The synthesized composite films were morphologically (through SEM and atomic force microscopy (AFM)) and structurally (through FT-IR and Raman spectroscopy) characterized. The thermal behavior of the composite films was also determined. The SEM and AFM analyses showed the presence of micro-structured hydroxyapatite particles in the film’s structure, as well as changes in the surface morphology. There was a significant decrease in the crystallinity of the composite films compared to the pure polymer, this being explained by a decrease in the arrangement of the polymer chains and a concurrent increase in the degree of their clutter. The presence of hydroxyapatite crystals did not have a significant influence on the degradation temperature of the composite film.

2 September 2021 in Nanomaterials
Verified
Journal Article
Open access
PDF file
CDCristina Rodica Dumitrescu
Cristina Rodica Dumitrescu
Ionela Andreea NeacsuIonela Andreea Neacsu
Ionela Andreea Neacsu
Vasile-Adrian SurduVasile-Adrian Surdu
Vasile-Adrian Surdu
Adrian Ionut NicoaraAdrian Ionut Nicoara
Adrian Ionut Nicoara
Iordache FlorinIordache Florin
Iordache Florin
EAEcaterina Andronescu
Ecaterina Andronescu
This research focused on the synthesis of apatite, starting from a natural biogenic calcium source (egg-shells) and its chemical and morpho-structural characterization in comparison with two commercial xenografts used as a bone substitute in dentistry. The synthesis route for the hydroxyapatite powder was the microwave-assisted hydrothermal technique, starting from annealed egg-shells as the precursor for lime and di-base ammonium phosphate as the phosphate precursor. The powders were characterized by Fourier-transform infrared spectroscopy (FTIR), X-ray diffraction (XRD), scanning electron microscopy (SEM), energy-dispersive X-ray analysis (EDAX), transmission electron microscopy (TEM), X-ray fluorescence spectroscopy (XRF), and cytotoxicity assay in contact with amniotic fluid stem cell (AFSC) cultures. Compositional and structural similarities or differences between the powder synthesized from egg-shells (HA1) and the two commercial xenograft powders—Bio-Oss®, totally deproteinized cortical bovine bone, and Gen-Os®, partially deproteinized porcine bone—were revealed. The HA1 specimen presented a single mineral phase as polycrystalline apatite with a high crystallinity (Xc 0.92), a crystallite size of 43.73 nm, preferential growth under the c axes (002) direction, where it mineralizes in bone, a nano-rod particle morphology, and average lengths up to 77.29 nm and diameters up to 21.74 nm. The surface of the HA1 nanoparticles and internal mesopores (mean size of 3.3 ± 1.6 nm), acquired from high-pressure hydrothermal maturation, along with the precursor’s nature, could be responsible for the improved biocompatibility, biomolecule adhesion, and osteoconductive abilities in bone substitute applications. The cytotoxicity assay showed a better AFSC cell viability for HA1 powder than the commercial xenografts did, similar oxidative stress to the control sample, and improved results compared with Gen-Os. The presented preliminary biocompatibility results are promising for bone tissue regeneration applications of HA1, and the study will continue with further tests on osteoblast differentiation and mineralization.

Verified
Journal Article
Open access
PDF file
Florin MiculescuFlorin Miculescu
Florin Miculescu
CLCristina Luță
Cristina Luță
ACAndreea Elena Constantinescu
Andreea Elena Constantinescu
AMAndreea Maidaniuc
Andreea Maidaniuc
Aura-Catalina MocanuAura-Catalina Mocanu
Aura-Catalina Mocanu
Lucian Toma CiocanLucian Toma Ciocan
Lucian Toma Ciocan
Calcium phosphates (CPs) used as biomaterials have been intensively studied in recent years. In most studies, the determination of the chemical composition is mandatory. Due to the versatility and possibilities of performing qualitative and quantitative compositional analyses, energy dispersive spectrometry (EDS) is a widely used technique in this regard. The range of calcium phosphates is very diverse, the first method of approximating the type of compound being EDS microanalysis, by assessing the atomic Ca/P ratio. The value of this ratio can be influenced by several factors correlated with instrumental parameters and analysed samples. This article highlights the influence of the electron beam acceleration voltage (1 kV–30 kV) and of the particle size of calcium phosphate powders on the EDS analysis results. The characterised powders were obtained from bovine bones heat-treated at 1200 °C for 2 h, which have been ground and granulometrically sorted by mechanical vibration. The granulometric sorting generated three types of samples, with particle sizes < 20 μm, < 40 μm and < 100 μm, respectively. These were morphologically and dimensionally analysed by scanning electron microscopy (SEM) and compositionally by EDS, after the spectrometer was calibrated with a standard reference material (SRM) from NIST (National Institute of Standards and Technology). The results showed that the adjusting of acceleration voltage and of the powder particle size significantly influences the spectrum profile and the results of EDS analyses, which can lead to an erroneous primary identification of the analysed calcium phosphate type.

8 July 2024 in Diagnostics
Verified
Journal Article
Open access
PDF file
Lucian Toma CiocanLucian Toma Ciocan
Lucian Toma Ciocan
VVVlad Gabriel Vasilescu
Vlad Gabriel Vasilescu
SRSabina-Ana Răuță
Sabina-Ana Răuță
MIHAELA PANTEAMIHAELA PANTEA
MIHAELA PANTEA
SPSilviu Mirel Pițuru
Silviu Mirel Pițuru
MIMarina Imre
Marina Imre
(1) Background: Intraoral scanners undergo rapid advancements in hardware and software, prompting frequent updates by manufacturers. (2) Aim: This study aimed to quantitatively assess the precision of full dental arch digital impressions obtained from four different intraoral scanners: Trios 5—3SHAPE, Copenhagen, Denmark, CEREC Primescan— Dentsply Sirona, New York, NY, USA, Planmeca Emerald S—Planmeca Oy, Helsinki, Finland, and Medit i700—Medit Corp, Seoul, Republic of Korea. (3) Methods: A maxillary virtual dental model (digital master model) was created in accordance with ISO standard 20896-1. Subsequently, a 3D-printed model was obtained from the master model’s STL file and scanned 15 times consecutively with each scanner. STL files were aligned with the master model’s STL using Medit Link—Medit Design software v.3.1.0. The accuracy was evaluated by measuring deviations in micrometers between each scanner’s scans and the master model. (4) Results: The study revealed variations in accuracy ranging from 23 to 32 µm across scans of the same dental arch, irrespective of the scanner used and scanning strategy employed. The anterior regions exhibited higher precision (Mean Absolute Deviation of 112 µm) compared to the posterior regions (Mean Absolute Deviation of 127 µm). Trios 5 demonstrated the smallest deviation (average 112 µm), indicating superior accuracy among the scanners tested. Emerald S and Medit i700 exhibited balanced performance (average 117 µm and 114 µm, respectively), while Primescan consistently displayed high deviation (average 127 µm). (5) Conclusions: Based on clinically accepted thresholds for accuracy in intraoral scanning, which are typically 200 µm for full arch scans, Trios 5 surpasses these benchmarks with its average deviation falling within the 200 µm range. Emerald S and Medit i700 also meet these standards, while Primescan, although showing high overall deviation, approaches the upper limit of clinical acceptability. Considering the limitations of an in vitro investigation, the findings demonstrate that each intraoral scanner under evaluation is capable of reliably and consistently capturing a full arch scan for dentate patients.

29 November 2021 in Materials
Verified
Journal Article
Open access
PDF file
Lucian Toma CiocanLucian Toma Ciocan
Lucian Toma Ciocan
Jana GhițmanJana Ghițman
Jana Ghițman
VVVlad Gabriel Vasilescu
Vlad Gabriel Vasilescu
Horia  IovuHoria Iovu
Horia Iovu
The tremendous technological and dental material progress led to a progressive advancement of treatment technologies and materials in restorative dentistry and prosthodontics. In this approach, CAD/CAM restorations have proven to be valuable restorative dental materials in both provisional and definitive restoration, owing to multifarious design, improved and highly tunable mechanical, physical and morphological properties. Thus far, the dentistry market offers a wide range of CAD/CAM restorative dental materials with highly sophisticated design and proper characteristics for a particular clinical problem or multiple dentistry purposes. The main goal of this research study was to comparatively investigate the micro-mechanical properties of various CAD/CAM restorations, which are presented on the market and used in clinical dentistry. Among the investigated dental specimens, hybrid ceramic-based CAD/CAM presented the highest micro-mechanical properties, followed by CAD/CAM PMMA-graphene, while the lowest micro-mechanical features were registered for CAD/CAM multilayered PMMA.

29 September 2022 in Nanomaterials
Verified
Journal Article
Open access
PDF file
Rebeca AlexaRebeca Alexa
Rebeca Alexa
Andreia CucuruzAndreia Cucuruz
Andreia Cucuruz
CGCristina Daniela Ghiţulicǎ
Cristina Daniela Ghiţulicǎ
GVGeorgeta Voicu
Georgeta Voicu
L(Liliana-Roxana Balahura (Stamat)
Liliana-Roxana Balahura (Stamat)
Marieta CostacheMarieta Costache
Marieta Costache
As bone diseases and defects are constantly increasing, the improvement of bone regeneration techniques is constantly evolving. The main purpose of this scientific study was to obtain and investigate biomaterials that can be used in tissue engineering. In this respect, nanocomposite inks of GelMA modified with hydroxyapatite (HA) substituted with Mg and Zn were developed. Using a 3D bioprinting technique, scaffolds with varying shapes and dimensions were obtained. The following analyses were used in order to study the nanocomposite materials and scaffolds obtained by the 3D printing technique: Fourier transform infrared spectrometry and X-ray diffraction (XRD), scanning electron microscopy (SEM), and micro-computed tomography (Micro-CT). The swelling and dissolvability of each scaffold were also studied. Biological studies, osteopontin (OPN), and osterix (OSX) gene expression evaluations were confirmed at the protein levels, using immunofluorescence coupled with confocal microscopy. These findings suggest the positive effect of magnesium and zinc on the osteogenic differentiation process. OSX fluorescent staining also confirmed the capacity of GelMA-HM5 and GelMA-HZ5 to support osteogenesis, especially of the magnesium enriched scaffold.