Hamed Ghaffari

Dr. Hamed Ghaffari


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
16 April 2021 in British Journal of Radiology
Verified
Journal Article
Closed access
MSMohammad Salehi
Mohammad Salehi
RMReza Mohammadi
Reza Mohammadi
HGHamed Ghaffari
Hamed Ghaffari
NSNahid Sadighi
Nahid Sadighi
RRReza Reiazi
Reza Reiazi
Objective: Pneumonia is a lung infection and causes the inflammation of the small air sacs (Alveoli) in one or both lungs. Proper and faster diagnosis of pneumonia at an early stage is imperative for optimal patient care. Currently, chest X-ray is considered as the best imaging modality for diagnosing pneumonia. However, the interpretation of chest X-ray images is challenging. To this end, we aimed to use an automated convolutional neural network-based transfer-learning approach to detect pneumonia in paediatric chest radiographs. Methods: Herein, an automated convolutional neural network-based transfer-learning approach using four different pre-trained models (i.e. VGG19, DenseNet121, Xception, and ResNet50) was applied to detect pneumonia in children (1–5 years) chest X-ray images. The performance of different proposed models for testing data set was evaluated using five performances metrics, including accuracy, sensitivity/recall, Precision, area under curve, and F1 score. Results: All proposed models provide accuracy greater than 83.0% for binary classification. The pre-trained DenseNet121 model provides the highest classification performance of automated pneumonia classification with 86.8% accuracy, followed by Xception model with an accuracy of 86.0%. The sensitivity of the proposed models was greater than 91.0%. The Xception and DenseNet121 models achieve the highest classification performance with F1-score greater than 89.0%. The plotted area under curve of receiver operating characteristics of VGG19, Xception, ResNet50, and DenseNet121 models are 0.78, 0.81, 0.81, and 0.86, respectively. Conclusion: Our data showed that the proposed models achieve a high accuracy for binary classification. Transfer learning was used to accelerate training of the proposed models and resolve the problem associated with insufficient data. We hope that these proposed models can help radiologists for a quick diagnosis of pneumonia at radiology departments. Moreover, our proposed models may be useful to detect other chest-related diseases such as novel Coronavirus 2019. Advances in knowledge: Herein, we used transfer learning as a machine learning approach to accelerate training of the proposed models and resolve the problem associated with insufficient data. Our proposed models achieved accuracy greater than 83.0% for binary classification.

9 June 2022 in British Journal of Radiology
Verified
Journal Article
Closed access
HGHamed Ghaffari
Hamed Ghaffari
HTHassan Tavakoli
Hassan Tavakoli
GJGila Pirzad Jahromi
Gila Pirzad Jahromi
Objectives: To employ different automated convolutional neural network (CNN)-based transfer learning (TL) methods for both binary and multiclass classification of Alzheimer’s disease (AD) using brain MRI. Methods: Herein, we applied three popular pre-trained CNN models (ResNet101, Xception, and InceptionV3) using a fine-tuned approach of TL on 3D T 1-weighted brain MRI from a subset of ADNI dataset (n = 305 subjects). To evaluate power of TL, the aforementioned networks were also trained from scratch for performance comparison. Initially, Unet network segmentedthe MRI scans into characteristic components of gray matter (GM), white matter (WM), and cerebrospinal fluid (CSF). The proposed networks were trained and tested over the pre-processed and augmented segmented and whole images for both binary (NC/AD + progressive mild cognitive impairment (pMCI)+stable MCI (sMCI)) and 4-class (AD/pMCI/sMCI/NC) classification. Also, two independent test sets from the OASIS (n = 30) and AIBL (n = 60) datasets were used to externally assess the performance of the proposed algorithms. Results: The proposed TL-based CNN models achieved better performance compared to the training CNN models from scratch. On the ADNI test set, InceptionV3-TL achieved the highest accuracy of 93.75% and AUC of 92.0% for binary classification, as well as the highest accuracy of 93.75% and AUC of 96.0% for multiclass classification of AD on the whole images. On the OASIS test set, InceptionV3-TL outperformed two other models by achieving 93.33% accuracy with 93.0% AUC in binary classification of AD on the whole images. On the AIBL test set, InceptionV3-TL also outperformed two other models in both binary and multiclass classification tasks on the whole MR images and achieved accuracy/AUC of 93.33%/95.0% and 90.0%/93.0%, respectively. The GM segment as input provided the highest performance in both binary and multiclass classification of AD, as compared to the WM and CSF segments. Conclusion: This study demonstrates the potential of applying deep TL approach for automated detection and classification of AD using brain MRI with high accuracy and robustness across internal and external test data, suggesting that these models can possibly be used as a supportive tool to assist clinicians in creating objective opinion and correct diagnosis. Advances in knowledge: We used CNN-based TL approaches and the augmentation techniques to overcome the insufficient data problem. Our study provides evidence that deep TL algorithms can be used for both binary and multiclass classification of AD with high accuracy.


22 May 2020 in Strahlentherapie und Onkologie
Verified
Journal Article
Closed access
MAMahdieh Afkhami Ardekani
Mahdieh Afkhami Ardekani
HGHamed Ghaffari
Hamed Ghaffari
MNMahmoud Navaser
Mahmoud Navaser
SMSeyed Hamid Zoljalali Moghaddam
Seyed Hamid Zoljalali Moghaddam
SRSoheila Refahi
Soheila Refahi

1 March 2019 in Strahlentherapie und Onkologie
Verified
Journal Article
Closed access
PDF file
SMseied rabi mehdi mahdavi
seied rabi mehdi mahdavi
HGHamed Ghaffari
Hamed Ghaffari
BMBahram Mofid
Bahram Mofid
ARAram Rostami
Aram Rostami
RRReza Reiazi
Reza Reiazi
LJLeila Janani
Leila Janani

29 May 2019
Verified
Journal Article
Open access
SRSajjad Rastegar
Sajjad Rastegar
JBJalal Beigi
Jalal Beigi
ESEhsan Saeidi
Ehsan Saeidi
ADAli Dezhkam
Ali Dezhkam
TMTofigh Mobaderi
Tofigh Mobaderi
HAHamid Abdollahi
Hamid Abdollahi
Reject analysis is as a quality indicator and critical tool for dose and image quality optimization in radiology departments. By reducing image rejection rate (RR), radiation dose to patients can be reduced effectively, yielding increased total cost-effectiveness. The aims of this study were to assess the rate of image rejection at 2 direct digital radiography (DR) departments to find the sources of rejection and to observe how radiology students and radiographers deal with image rejection.