Mahdieh Afkhami Ardekani

Mahdieh Afkhami Ardekani

Auto-generated profile, based on publicly available information

Mahdieh Afkhami Ardekani

Department of Radiology, Faculty of Para-Medicine, Hormozgan University of Medical Sciences, Bandar-Abbas, Iran

Research Focus & Metrics

Academic Career Length

10Years (2017-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2018 in Journal of Medical Signals & Sensors
Verified
Journal Article
Open access
PDF file
BFBagher Farhood
Bagher Farhood
WPWrya Parwaie
Wrya Parwaie
SRSoheila Refahi
Soheila Refahi
MAMahdiehAfkhami Ardekani
MahdiehAfkhami Ardekani
With the advent of complex and precise radiation therapy techniques, the use of relatively small fields is needed. Using such field sizes can cause uncertainty in dosimetry; therefore, special attention is required both in dose calculations and measurements. There are several challenges in small-field dosimetry such as the steep gradient of the radiation field, volume averaging effect, lack of charged particle equilibrium, partial occlusion of radiation source, beam alignment, and unable to use a reference dosimeter. Due to these challenges, special dosimeters are needed for small-field dosimetry, and this review article discusses this topic.


22 May 2020 in Strahlentherapie und Onkologie
Verified
Journal Article
Closed access
MAMahdieh Afkhami Ardekani
Mahdieh Afkhami Ardekani
HGHamed Ghaffari
Hamed Ghaffari
MNMahmoud Navaser
Mahmoud Navaser
SMSeyed Hamid Zoljalali Moghaddam
Seyed Hamid Zoljalali Moghaddam
SRSoheila Refahi
Soheila Refahi

1 June 2018 in Journal of Radiology Nursing
Verified
Journal Article
Closed access
SBSomayyeh Babaloui
Somayyeh Babaloui
WPWrya Parwaie
Wrya Parwaie
SRSoheila Refahi
Soheila Refahi
MAMalihe Abrazeh
Malihe Abrazeh
MAMahdieh Afkhami Ardekani
Mahdieh Afkhami Ardekani

3 March 2020 in Journal of Biochemical and Molecular Toxicology
Verified
Journal Article
Closed access
PDF file
AHAhmad Hormati
Ahmad Hormati
SASajjad Ahmadpour
Sajjad Ahmadpour
MAMahdieh Afkhami Ardekani
Mahdieh Afkhami Ardekani
FKFatemeh Khodadust
Fatemeh Khodadust
SRSoheila Refahi
Soheila Refahi

26 August 2022 in Polish Journal of Radiology
Verified
Journal Article
Open access
PDF file
MSMohammad Salehi
Mohammad Salehi
MAMahdieh Afkhami Ardekani
Mahdieh Afkhami Ardekani
ATAlireza Bashari Taramsari
Alireza Bashari Taramsari
HGHamed Ghaffari
Hamed Ghaffari
MHMohammad Haghparast
Mohammad Haghparast
Introduction: The novel coronavirus COVID-19, which spread globally in late December 2019, is a global health crisis. Chest computed tomography (CT) has played a pivotal role in providing useful information for clinicians to detect COVID-19. However, segmenting COVID-19-infected regions from chest CT results is challenging. Therefore, it is desirable to develop an efficient tool for automated segmentation of COVID-19 lesions using chest CT. Hence, we aimed to propose 2D deep-learning algorithms to automatically segment COVID-19-infected regions from chest CT slices and evaluate their performance.Material and methods: Herein, 3 known deep learning networks: U-Net, U-Net++, and Res-Unet, were trained from scratch for automated segmenting of COVID-19 lesions using chest CT images. The dataset consists of 20 labelled COVID-19 chest CT volumes. A total of 2112 images were used. The dataset was split into 80% for training and validation and 20% for testing the proposed models. Segmentation performance was assessed using Dice similarity coefficient, average symmetric surface distance (ASSD), mean absolute error (MAE), sensitivity, specificity, and precision.Results: All proposed models achieved good performance for COVID-19 lesion segmentation. Compared with Res-Unet, the U-Net and U-Net++ models provided better results, with a mean Dice value of 85.0%. Compared with all models, U-Net gained the highest segmentation performance, with 86.0% sensitivity and 2.22 mm ASSD. The U-Net model obtained 1%, 2%, and 0.66 mm improvement over the Res-Unet model in the Dice, sensitivity, and ASSD, respectively. Compared with Res-Unet, U-Net++ achieved 1%, 2%, 0.1 mm, and 0.23 mm improvement in the Dice, sensitivity, ASSD, and MAE, respectively.Conclusions: Our data indicated that the proposed models achieve an average Dice value greater than 84.0%. Two-dimensional deep learning models were able to accurately segment COVID-19 lesions from chest CT images, assisting the radiologists in faster screening and quantification of the lesion regions for further treatment. Nevertheless, further studies will be required to evaluate the clinical performance and robustness of the proposed models for COVID-19 semantic segmentation.