This article investigates a dc solid-state transformer (DCSST) with dc fault ride-through (FRT) capability for medium-voltage dc (MVDC) systems. The FRT requirement for DCSST in dc grid is investigated. Short-circuit fault clearance on the medium-voltage (MV) side is realized by introducing full-bridge converters with cascaded dc converter modules on the MV side of the DCSST. The FRT strategy under typical voltage sags is analyzed. Factors affecting the fault clearing and system recovery are considered, including the number of full-bridge converters, the values of dc inductance, and the dc-link bus voltage. The concept is verified with both simulations and experiments.
30 April 2025 in IEEE Transactions on Power Electronics
Control plays a critical role in achieving efficient operation of dual-bridge series resonant dc–ac converters (DBSRC). However, realizing real-time, optimal, and robust control of DBSRC to maximize its efficiency is generally difficult, due to the complex interplay of control variables, efficiency, power demand, and voltage conversion ratio requirements. Here, we propose an optimal control strategy for DBSRC, suitable for real-time closed-loop controller implementation. The key to the strategy is the development of a closed-form analytical solution of the optimal control variables for maximum system efficiency and output power regulation. Detailed derivation of the optimal control solution is provided. The effectiveness of the proposed control strategy is validated on a 200-W DBSRC prototype. The results confirm that the proposed control strategy can achieve real-time and robust control performance, with over 2% efficiency improvement over the conventional single-phase-shift control strategy.
1 September 2025 in IEEE Transactions on Power Electronics
Conventional single-stage dual active bridge (DAB) microinverters typically have a bulky capacitor for decoupling double-line frequency power and a significant pulsation in the input current, leading to reduced power density and degraded maximum power point tracking (MPPT) performance. This article presents a new modulation method for single-stage DAB microinverters, allowing for substantial reductions in both the required decoupling capacitance and the input current ripple without hardware modifications. This is achieved by repurposing the inherent primary-side dc-blocking capacitor as an active decoupling capacitor. The operating principles of the proposed modulation scheme are comprehensively analyzed, and an automatic decoupling control system based on large-signal modelling is designed. A 500 W experimental prototype is built for validation. Experimental results demonstrate that the proposed modulation method reduces the decoupling capacitor volume by 75% and decreases the double-line frequency pulsation in the input current by 96%, thereby improving the circuit’s power density and MPPT accuracy.
12 September 2025 in IEEE Transactions on Power Electronics
Conventional single-stage dual active bridge microinverters typically suffer from bulky input capacitors for double-line frequency power decoupling, significant input current pulsation, and excessive circulating current under single-phase-shift modulation. This article proposes a novel synergistic modulation method to comprehensively address these limitations. The proposed method achieves active power decoupling under arbitrary power factor conditions by repurposing the inherent primary-side dc-blocking capacitor, thus avoiding any hardware modifications. Meanwhile, the modulation parameters are optimized to substantially reduce the tank current. A systematic theoretical analysis is conducted, and a large-signal-based automatic decoupling control loop is developed. The experimental results on a 500-VA prototype demonstrate that the proposed modulation method reduces the decoupling capacitor volume by 75%, suppresses the double-line frequency pulsation in the input current by 87%, and decreases the root-mean-square value of the tank current by 27%, thereby improving the circuit’s power density, maximum power point tracking accuracy, and overall efficiency.
With the increasing penetration of distributed generation, electric vehicles and single-phase loads in the low-voltage distribution network, flexible interconnected systems face more prominent three-phase unbalance and direct-current (DC)-side voltage regulation problems. Unbalanced loads not only lead to asymmetry of alternating current (AC)-side voltage and current but also introduce low-frequency ripples into the common DC bus through the power-coupling relationship and further cause the neutral-point potential shift of the split capacitors. To address these problems, this paper takes a double-ended flexible interconnection system with an integrated three-level Buck–Boost energy storage interface as the research object and proposes a DC-side total-voltage-neutral-point cooperative control strategy. Firstly, the coupling relationship between AC-side power fluctuation and DC-side voltage state under unbalanced conditions is established to analyze the formation mechanism of DC bus low-frequency ripple and neutral-point potential offset; secondly, based on the neutral-point access characteristic of three-level Buck–Boost, the DC-side modulation quantity is decomposed into a common-mode duty cycle and a differential-mode duty cycle. Among them, the common-mode duty cycle is used to regulate the total power exchange on the energy storage side to achieve DC bus total voltage maintenance and low-frequency ripple suppression; the differential-mode duty cycle is used to regulate the difference between the duty cycles of the upper and lower half-bridges to achieve capacitor charging and discharging distribution regulation and neutral-point potential balance. Finally, a simulation model is built to verify the proposed control strategy. The simulation results show that the proposed method is able to stabilize the DC bus voltage around 800 V under power step disturbance and suppress the midpoint voltage deviation from a low-frequency oscillation of about 10 V to within about ±1 V. This verifies the effectiveness of the control strategy under unbalanced load and power disturbance conditions.
Stable and rapid output-voltage regulation is crucial in dynamic wireless charging (DWC) systems for electric vehicles (EVs), because transmitter-side perturb-and-observe maximum energy efficiency tracking (P&O-MEET) can reliably evaluate input current only after the receiver voltage has settled. Conventional proportional-integral (PI) control often exhibits limited disturbance rejection under motion-induced coupling variation, load changes, and phase-shift perturbations, thereby limiting effective-window delivered energy. This paper introduces ultra-local model-free control (MFC) for receiver-side voltage regulation in DWC. MFC uses real-time input/output data to estimate lumped dynamics and disturbances without requiring an accurate plant model. A small-signal analysis explains how the cascaded MFC structure reshapes the disturbance-rejection transfer function relative to a single-loop PI baseline. Simulations and experiments on a 5-W, 1/13-scale control-oriented prototype show that MFC reduces voltage settling time by 48.1% and voltage ripple by 22.0% on average under representative DWC disturbances. This faster receiver response permits a shorter P&O update period, reducing static MEET convergence time and dynamic minimum-input-current tracking time by over 40% in the tested cases. At 70 km/h scaled-equivalent speed, the MFC-based system maintains effective tracking whereas the PI-based system fails to converge within the effective charging window. Consequently, MFC yields per-pass gains of 3.69% in effective-window delivered energy and 1.88% in effective-window DC-input-to-load efficiency, indicating potential cumulative benefits over multi-segment DWC roadways.