Kurt Schicho

Prof. Dr. Kurt Schicho

orcid

Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
20 April 2005 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
KSKurt Schicho
Kurt Schicho
MFMichael Figl
Michael Figl
MDMarkus Donat
Markus Donat
WBWolfgang Birkfellner
Wolfgang Birkfellner
RSRudolf Seemann
Rudolf Seemann
RERolf Ewers
Rolf Ewers
This study aims at a comparative evaluation of two recently introduced electromagnetic tracking systems under reproducible simulated operating-room (OR) conditions: the recently launched Medtronic StealthStation, Treon-EM and the NDI Aurora. We investigate if and to what extent these systems provide improved performance and stability in the presence of surgical instruments as possible sources of distortions compared with earlier reports on electromagnetic tracking technology. To investigate possible distortions under pseudo-realistic OR conditions, a large Langenbeck hook, a dental drill with its handle and an ultrasonic (US) scanhead are fixed on a special measurement rack at variable distances from the navigation sensor. The position measurements made by the Treon-EM were least affected by the presence of the instruments. The lengths of the mean deviation vectors were 0.21 mm for the Langenbeck hook, 0.23 mm for the drill with handle and 0.56 mm for the US scanhead. The Aurora was influenced by the three sources of distortion to a higher degree. A mean deviation vector of 1.44 mm length was observed in the vicinity of the Langenbeck hook, 0.53 mm length with the drill and 2.37 mm due to the US scanhead. The maximum of the root mean squared error (RMSE) for all coordinates in the presence of the Langenbeck hook was 0.3 mm for the Treon and 2.1 mm for the Aurora; the drill caused a maximum RMSE of 0.2 mm with the Treon and 1.2 mm with the Aurora. In the presence of the US scanhead, the maximum RMSE was 1.4 mm for the Treon and 5.1 mm for the Aurora. The new generation of electromagnetic tracking systems has significantly improved compared to common systems that were available in the middle of the 1990s and has reached a high level of technical development. We conclude that, in general, both systems are suitable for routine clinical application.

1 April 2007 in Journal of Neurosurgery
Verified
Journal Article
Closed access
KSKurt Schicho
Kurt Schicho
MFMichael Figl
Michael Figl
RSRudolf Seemann
Rudolf Seemann
MDMarkus Donat
Markus Donat
MPMichael L. Pretterklieber
Michael L. Pretterklieber
RERolf Ewers
Rolf Ewers
✓The authors compared the accuracy of laser surface scanning patient registration using the commercially available Fazer (Medtronic, Inc.) with the conventional registration procedure based on fiducial markers (FMs) in computer-assisted surgery. Four anatomical head specimens were prepared with 10 titanium microscrews placed at defined locations and scanned with a 16-slice spiral computed tomography unit. To compare the two registration methods, each method was applied five times for each cadaveric specimen; thus data were obtained from 40 registrations. Five microscrews (selected following a randomization protocol) were used for each FM-based registration; the other five FMs were selected for coordinate measurements by touching with a point measurement stylus. Coordinates of these points were also measured manually on the screen of the navigation computer. Coordinates were measured in the same manner after laser surface registration. The root mean square error as calculated by the navigation system ranged from 1.3 to 3.2 mm (mean 1.8 mm) with the Fazer and from 0.3 to 1.8 mm (mean 1.0 mm) with FM-based registration. The overall mean deviations (the arithmetic mean of the mean deviations of measurements on the four specimens) were 3.0 mm (standard deviation [SD] range 1.4–2.6 mm) with the Fazer and 1.4 mm (SD range 0.4–0.9 mm) with the FMs. The Fazer registration scans 300 surface points. Statistical tests showed the difference in the accuracy of these methods to be highly significant. In accordance with the findings of other groups, the authors concluded that the inclusion of a larger number of registration points might improve the accuracy of Fazer registration.

20 November 2018 in Scientific Reports
Verified
Journal Article
Open access
PDF file
RWRaimund Winter
Raimund Winter
PDPeter Dungel
Peter Dungel
FRFrederike Marie Josephine Reischies
Frederike Marie Josephine Reischies
SRSabrina Rohringer
Sabrina Rohringer
PSPaul Slezak
Paul Slezak
KSKurt Schicho
Kurt Schicho
The application of light in various therapeutic settings known as Photobiomodulation (PBM) is well established. Indications are the improvement of wound healing and tissue regeneration, scarring, and perfusion as well as pain therapy. Tissue perfusion is mandatory for successful wound healing. Nevertheless, there is a lack of mechanistic studies. We investigate the potential effect of PBM from light emitting diodes (LED) at 635 nm, 80 mW/cm2, 24 J/cm2 on angiogenesis in a two-part study: 1.) Investigation of the effect of PBM on the proliferation of endothelial cells and on vasculogenesis in a co-culture model of endothelial cells and stem cells. 2.) Investigation of the influence of PBM at chick egg chorioallantoic membrane (CAM) assays with fresh human skin xenografts. In both study phases, we observed a stimulating effect of PBM at 635 nm; in part 1: for proliferation of HUVEC (human umbilical vein endothelial cells) (25833 ± 12859 versus 63002 ± 35760 cells/well, p < 0.05, for cellular network formation (2.1 ± 2.1 versus 4.6 ± 3.5, p < 0.05) and for less cell compactness p = 0.01; in part 2: for the increase of number of vessel junctions per ROI (region of interest) (15.9 ± 2.6 versus 20.8 ± 5.4, p < 0.05). Our results suggest significant promotion of angiogenesis by PBM at 635 nm in vitro and in vivo.

30 August 2006 in Medical Physics
Verified
Journal Article
Closed access
KSKurt Schicho
Kurt Schicho
MFMichael Figl
Michael Figl
RSRudolf Seemann
Rudolf Seemann
RERolf Ewers
Rolf Ewers
JLJ. Thomas Lambrecht
J. Thomas Lambrecht
CKClemens Klug
Clemens Klug

1 September 2022 in Cancers
Verified
Journal Article
Open access
PDF file
LFLorenz Faihs
Lorenz Faihs
BFBardia Firouz
Bardia Firouz
PSPaul Slezak
Paul Slezak
CSCyrill Slezak
Cyrill Slezak
MWMichael Weißensteiner
Michael Weißensteiner
PDPeter Dungel
Peter Dungel
Angiogenesis is a highly regulated process. It promotes tissue regeneration and contributes to tumor growth. Existing therapeutic concepts interfere with different steps of angiogenesis. The quantification of the vasculature is of crucial importance for research on angiogenetic effects. The chorioallantoic membrane (CAM) assay is widely used in the study of angiogenesis. Ex ovo cultured chick embryos develop an easily accessible, highly vascularised membrane on the surface. Tumor xenografts can be incubated on this membrane enabling studies on cancer angiogenesis and other major hallmarks. However, there is no commonly accepted gold standard for the quantification of the vasculature of the CAM. We compared four widely used measurement techniques to identify the most appropriate one for the quantification of the vascular network of the CAM. The comparison of the different quantification methods suggested that the CAM assay application on the IKOSA platform is the most suitable image analysis application for the vasculature of the CAM. The new CAM application on the IKOSA platform turned out to be a reliable and feasible tool for practical use in angiogenesis research. This novel image analysis software enables a deeper exploration of various aspects of angiogenesis and might support future research on new anti-angiogenic strategies for cancer treatment.

22 June 2007 in Clinical Oral Implants Research
Verified
Journal Article
Closed access
PDF file
KSKurt Schicho
Kurt Schicho
JKJohann Kastner
Johann Kastner
RKRoman Klingesberger
Roman Klingesberger
RSRudolf Seemann
Rudolf Seemann
GEGeorg Enislidis
Georg Enislidis
RERolf Ewers
Rolf Ewers