Christoph Hitzenberger

Prof. Dr. Christoph Hitzenberger

orcid

Research Focus & Metrics

Academic Career Length

42Years (1985-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
21 April 2003 in Optics Express
Verified
Journal Article
Closed access
PDF file
Rainer LeitgebRainer Leitgeb
Rainer Leitgeb
CHChristoph Hitzenberger
Christoph Hitzenberger
AFAdolf Fercher
Adolf Fercher
In this article we present a detailed discussion of noise sources in Fourier Domain Optical Coherence Tomography (FDOCT) setups. The performance of FDOCT with charge coupled device (CCD) cameras is compared to current standard time domain OCT systems. We describe how to measure sensitivity in the case of FDOCT and confirm the theoretically obtained values. It is shown that FDOCT systems have a large sensitivity advantage and allow for sensitivities well above 80dB, even in situations with low light levels and high speed detection.

20 January 2003 in Reports on Progress in Physics
Verified
Journal Article
Closed access
AFA F Fercher
A F Fercher
WDW Drexler
W Drexler
CHChristoph Hitzenberger
Christoph Hitzenberger
TLT Lasser
T Lasser

1 May 1995 in Optics Communications
Verified
Journal Article
Closed access
AFA.F. Fercher
A.F. Fercher
CHChristoph Hitzenberger
Christoph Hitzenberger
GKG. Kamp
G. Kamp
SES.Y. El-Zaiat
S.Y. El-Zaiat

24 February 2017 in Biomedical Optics Express
Verified
Journal Article
Open access
PDF file
JBJohannes F. de Boer
Johannes F. de Boer
CHChristoph Hitzenberger
Christoph Hitzenberger
YYYoshiaki Yasuno
Yoshiaki Yasuno
Optical coherence tomography (OCT) is now a well-established modality for high-resolution cross-sectional and three-dimensional imaging of transparent and translucent samples and tissues. Conventional, intensity based OCT, however, does not provide a tissue-specific contrast, causing an ambiguity with image interpretation in several cases. Polarization sensitive (PS) OCT draws advantage from the fact that several materials and tissues can change the light’s polarization state, adding an additional contrast channel and providing quantitative information. In this paper, we review basic and advanced methods of PS-OCT and demonstrate its use in selected biomedical applications.

1 October 1998 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
WDWolfgang Drexler
Wolfgang Drexler
OFOliver Findl
Oliver Findl
RMRupert Michael Menapace
Rupert Michael Menapace
GRGeorg Rainer
Georg Rainer
CVClemens Vass
Clemens Vass
AFAdolf F Fercher
Adolf F Fercher

1 July 1993 in American Journal of Ophthalmology
Verified
Journal Article
Closed access
AFAdolf F. Fercher
Adolf F. Fercher
CHChristoph Hitzenberger
Christoph Hitzenberger
WDWolfgang Drexler
Wolfgang Drexler
GKGerhard Kamp
Gerhard Kamp
HSHarald Sattmann
Harald Sattmann