Juan Manuel Lopez Navarro

Dr. Juan Manuel Lopez Navarro

Grupo de Investigación en Instrumentación y Acústica Aplicada, Departamento de Telemática y Electrónica, Universidad Politécnica de Madrid, 28040 Madrid, Spain
orcid

Research Focus & Metrics

Academic Career Length

28Years (1999-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 February 2014 in Applied Acoustics
Verified
Journal Article
Closed access
JAJ. Alonso
J. Alonso
JNJuan Manuel Lopez Navarro
Juan Manuel Lopez Navarro
Ignacio PavónIgnacio Pavón
Ignacio Pavón
MRM. Recuero
M. Recuero
CACésar Asensio
César Asensio
ABA. Bravo
A. Bravo

29 March 2020 in Sensors
Verified
Journal Article
Open access
PDF file
LSLuis Francisco Sigcha
Luis Francisco Sigcha
Nelson CostaNelson Costa
Nelson Costa
Ignacio PavónIgnacio Pavón
Ignacio Pavón
Susana Pinto CostaSusana Pinto Costa
Susana Pinto Costa
Pedro ArezesPedro Arezes
Pedro Arezes
GAGuillermo de Arcas
Guillermo de Arcas
Freezing of gait (FOG) is one of the most incapacitating motor symptoms in Parkinson’s disease (PD). The occurrence of FOG reduces the patients’ quality of live and leads to falls. FOG assessment has usually been made through questionnaires, however, this method can be subjective and could not provide an accurate representation of the severity of this symptom. The use of sensor-based systems can provide accurate and objective information to track the symptoms’ evolution to optimize PD management and treatments. Several authors have proposed specific methods based on wearables and the analysis of inertial signals to detect FOG in laboratory conditions, however, its performance is usually lower when being used at patients’ homes. This study presents a new approach based on a recurrent neural network (RNN) and a single waist-worn triaxial accelerometer to enhance the FOG detection performance to be used in real home-environments. Also, several machine and deep learning approaches for FOG detection are evaluated using a leave-one-subject-out (LOSO) cross-validation. Results show that modeling spectral information of adjacent windows through an RNN can bring a significant improvement in the performance of FOG detection without increasing the length of the analysis window (required to using it as a cue-system).

1 October 2013 in Fusion Engineering and Design
Verified
Journal Article
Open access
JVJesús Vega
Jesús Vega
SDSebastian Dormido
Sebastian Dormido
JNJuan Manuel Lopez Navarro
Juan Manuel Lopez Navarro
AMAndrea Murari
Andrea Murari
JRJesús M. Ramírez
Jesús M. Ramírez
RFRobert Felton
Robert Felton

4 January 2021 in Sensors
Verified
Journal Article
Open access
PDF file
LSLuis Francisco Sigcha
Luis Francisco Sigcha
Ignacio PavónIgnacio Pavón
Ignacio Pavón
Nelson CostaNelson Costa
Nelson Costa
Susana Pinto CostaSusana Pinto Costa
Susana Pinto Costa
MGMiguel Gago
Miguel Gago
GAGuillermo de Arcas
Guillermo de Arcas
Resting tremor in Parkinson’s disease (PD) is one of the most distinctive motor symptoms. Appropriate symptom monitoring can help to improve management and medical treatments and improve the patients’ quality of life. Currently, tremor is evaluated by physical examinations during clinical appointments; however, this method could be subjective and does not represent the full spectrum of the symptom in the patients’ daily lives. In recent years, sensor-based systems have been used to obtain objective information about the disease. However, most of these systems require the use of multiple devices, which makes it difficult to use them in an ambulatory setting. This paper presents a novel approach to evaluate the amplitude and constancy of resting tremor using triaxial accelerometers from consumer smartwatches and multitask classification models. These approaches are used to develop a system for an automated and accurate symptom assessment without interfering with the patients’ daily lives. Results show a high agreement between the amplitude and constancy measurements obtained from the smartwatch in comparison with those obtained in a clinical assessment. This indicates that consumer smartwatches in combination with multitask convolutional neural networks are suitable for providing accurate and relevant information about tremor in patients in the early stages of the disease, which can contribute to the improvement of PD clinical evaluation, early detection of the disease, and continuous monitoring.

11 September 2013 in Nuclear Fusion
Verified
Journal Article
Closed access
SDSebastian Dormido
Sebastian Dormido
JVJesús Vega
Jesús Vega
JRJ.M. Ramírez
J.M. Ramírez
AMA. Murari
A. Murari
RMR. Moreno
R. Moreno
JCJet-Efda Contributors
Jet-Efda Contributors

22 January 2020 in Sensors
Verified
Journal Article
Open access
PDF file
JNJuan Manuel Lopez Navarro
Juan Manuel Lopez Navarro
JAJesús Alonso
Jesús Alonso
CACésar Asensio
César Asensio
Ignacio PavónIgnacio Pavón
Ignacio Pavón
LGLuis Gasco
Luis Gasco
GAGuillermo de Arcas
Guillermo de Arcas
Presently, large cities have significant problems with noise pollution due to human activity. Transportation, economic activities, and leisure activities have an important impact on noise pollution. Acoustic noise monitoring must be done with equipment of high quality. Thus, long-term noise monitoring is a high-cost activity for administrations. For this reason, new alternative technological solutions are being used to reduce the costs of measurement instruments. This article presents a design for a versatile electronic device to measure outdoor noise. This device has been designed according to the technical standards for this type of instrument, which impose strict requirements on both the design and the quality of the device’s measurements. This instrument has been designed under the original equipment manufacturer (OEM) concept, so the microphone–electronics set can be used as a sensor that can be connected to any microprocessor-based device, and therefore can be easily attached to a monitoring network. To validate the instrument’s design, the device has been tested following the regulations of the calibration laboratories for sound level meters (SLM). These tests allowed us to evaluate the behavior of the electronics and the microphone, obtaining different results for these two elements. The results show that the electronics and algorithms implemented fully fit within the requirements of type 1 noise measurement instruments. However, the use of an electret microphone reduces the technical features of the designed instrument, which can only fully fit the requirements of type 2 noise measurement instruments. This situation shows that the microphone is a key element in this kind of instrument and an important element in the overall price. To test the instrument’s quality and show how it can be used for monitoring noise in smart wireless acoustic sensor networks, the designed equipment was connected to a commercial microprocessor board and inserted into the infrastructure of an existing outdoor monitoring network. This allowed us to deploy a low-cost sub-network in the city of Málaga (Spain) to analyze the noise of conflict areas due to high levels of leisure noise. The results obtained with this equipment are also shown. It has been verified that this equipment meets the similar requirements to those obtained for type 2 instruments for measuring outdoor noise. The designed equipment is a two-channel instrument, that simultaneously measures, in real time, 86 sound noise parameters for each channel, such as the equivalent continuous sound level (Leq) (with Z, C, and A frequency weighting), the peak level (with Z, C, and A frequency weighting), the maximum and minimum levels (with Z, C, and A frequency weighting), and the impulse, fast, and slow time weighting; seven percentiles (1%, 5%, 10%, 50%, 90%, 95%, and 99%); as well as continuous equivalent sound pressure levels in the one-third octave and octave frequency bands.