Ren Guoying

Ren Guoying

orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2020 in Science Progress
Verified
Journal Article
Open access
PDF file
SXShenglong Xie
Shenglong Xie
RGRen Guoying
Ren Guoying
JZJunjiang Zhu
Junjiang Zhu
As one of the key parts of rotary machine, the fault diagnosis and running condition monitoring of rolling bearings are of great importance for normal working and safe production of rotary machine. However, the traditional diagnosis approaches merely count on artificial feature extraction and domain expertise. Meanwhile, the existing convolutional neural networks (CNNs) have the problem of low fault recognition rates. This paper proposes a novel convolutional neural network with one-dimensional structure (ODCNN) for the automatical fault diagnosis of rolling bearings, which adopts six sets of convolutional and max-pooling layers to extract signal features and applies a flattening convolutional layer followed by two fully-connected layers for feature classification. The architectures of one-dimensional LeNet-5, AlexNet, and the proposed ODCNN are illustrated in detail, followed by the obtaining of training and testing samples, which is pre-processed by overlapping the vibration signals of rolling bearings. Finally, the classification experiment is carried out. The experimental results show that the ODCNN has higher fault diagnosis rates and can achieve high accuracy with load variant. Additionally, the extracted features of three CNNs are visualized, which illustrate that the new CNN has a better classification capacity.

19 July 2022 in Applied Sciences
Verified
Journal Article
Open access
PDF file
WPwang peng
wang peng
HZHongliang Zhao
Hongliang Zhao
RGRen Guoying
Ren Guoying
Aiming to address the disadvantages of the low automation degree of the traditional steel measuring tape verification device, as well as the high labor intensity of metrologists, high time costs, and low measurement accuracy, this paper develops a new automatic steel measuring tape calibration device based on machine vision technology. In this study, the key components, such as the tape-winding mechanism, machine vision system, force measuring device, and tape-retracting device, were designed. Three different scribed line identification and location algorithms, processing the longest line, the closest to the starting line, the highest line, etc., were designed to adapt to different types of steel measuring tape. Lastly, indication error and measurement repeatability tests were carried out. The results showed that the standard device can carry out the verification and calibration of steel measuring tape, and the maximum repeatability of the indication error of the test objects was 0.025 mm, 0.038 mm, and 0.030 mm, respectively, and the indication error of each object was within the allowable error limits. The uncertainty evaluation of the indication error of each test object was 0.16 mm, 0.54 mm, 0.78 mm, which was not more than one third of the maximum permissible error value. Hence, the measuring principle, method, and procedure of the calibration device are shown to be scientific and feasible.

23 April 2020 in Sensors
Verified
Journal Article
Open access
PDF file
RGRen Guoying
Ren Guoying
XQXinghua Qu
Xinghua Qu
XCXiangjun Chen
Xiangjun Chen
Trigger probes are widely used in precision manufacturing industries such as coordinate measuring machines (CMM) and high-end computer numerical control(CNC) machine tools for quality control. Their performance and accuracy often determine the measurement results and the quality of the product manufacturing. However, because there is no accurate measurement of the trigger force in different directions of the probe, and no special measuring device to calibrate the characteristic parameters of the probe in traditional measurement methods, it is impossible to exactly compensate for the measurement error caused by the trigger force of the probe in the measurement process. The accuracy of the measurement of the equipment can be improved by abiding by the Abbé principle. Thus, in order to better evaluate the performance parameters of the probe and realize the accurate compensation for its errors, this paper presents a method which can directly measure the performance parameters of the trigger probe based on the Abbé measurement principle, expounds the measurement principle, the establishment of the mathematical model, and the calibration system, and finishes with an experimental verification and measurement uncertainty analysis. The experimental results show that this method can obtain the exact calibration errors of the performance parameters of the trigger probe intuitively, realize the compensation for the errors of the probe in the measurement process, and effectively improve the measurement accuracy.

21 November 2018 in Applied Sciences
Verified
Journal Article
Open access
PDF file
RGRen Guoying
Ren Guoying
XQXinghua Qu
Xinghua Qu
SDShuang Ding
Shuang Ding
In the precise displacement measurement based on laser interferometry, the measurement technology for the refractive index of air is widely used to improve the measurement accuracy. However, the existing measurement method of the refractive index of air based on direct measurement is not easy to realize in practical work because of its complex measurement principle and the huge volume of the measurement device; while the measurement accuracy and speed based on the indirect method cannot adapt to the real-time, fast and accurate measurement requirements of industrially changing environments, resulting in distortion of the results. In this study, a measurement method of the refractive index of air based on a special material etalon is proposed. The method enables rapid and direct measurement of the air refractive index when the environment changes and it is given the realization process. Finally, the experimental results show that the deviation between this method and the modified Edlen formula is about 2.5 × 10−7, and that this method can quickly reflect the changes of the environment, which prove the correctness of this method and its ability manage rapid environmental responses. This method is worth popularizing in industrial measurement.

19 March 2020 in Applied Sciences
Verified
Journal Article
Open access
PDF file
RGRen Guoying
Ren Guoying
XQXinghua Qu
Xinghua Qu
XCXiangjun Chen
Xiangjun Chen
A step gauge is a commonly used length standard for international comparison, and its calibration accuracy is often used as a sign to measure a country’s length Calibration and Measurement Capability (CMC). Based on this, some developed countries and developing countries all over the world have been carrying out the research of precision calibration technology for step gauge. On the basis of summarizing the current situation of step gauge calibration technology in other countries, this paper presents a new computational model of step gauge calibration based on the Synthesis Technology of Multi-Path Laser Interferometers (SMLI) and an auto-collimator, which can synthesize the three laser light paths into the measured centerline of step gauge. It is very important to obtain a good measurement accuracy for the step gauge, conformed to the Abbe principle, no matter where it is installed on the CMM measurement platform. In this paper, the development of the mathematical model, the data collection algorithms, data analysis techniques, and measurement uncertainty budgets are discussed. Finally, the experimental measurement is carried out and the measurement accuracy is verified to be effective. The results show that this method can effectively avoid the influence of Abbe error in length measurement, and significantly enhance the calibration accuracy of the step gauge.