With the help of a modified Einthoven Body Network of lumped impedances, transient electrical calculations are carried out for various lightning impact mechanisms on human beings. By varying the impedance or resistance values, including the environment modeled by impedances too, as well as the parameters of the lightning, strokes and flash, rough statements about the severity of injuries to humans can be obtained simply and fast. This kind of analysis can also be helpful in assessing the effectiveness of personal lightning protection measures when it is not possible to use highly specialized field simulation tools. The body current and voltage as well as the currents in heart and brain stem were considered, from which the flowed charges and energies were derived. It could be confirmed that side flash and touch voltage cause particularly serious effects to humans, and that step voltage and aborted upward leader cause least injuries. Direct strike has slightly reduced harmfulness from a purely electrical viewpoint because of the almost always occurring body flashover. Depending on the object of investigation, body, heart, or brain stem, either energy or charge or both integral quantities are decisive. For energy, as the mostly essential quantity, an energy-time limit characteristic for the permissible lightning current load is proposed for short pulses.
The use of HVDC systems is increasing in number due to technological innovations, increasing power capacity and increasing customer demand. The characteristics of insulation systems under composite DC and LI voltage must be examined and clarified. In this study, firstly, experimental circuits were designed to generate and measure composite DC and LI high voltage using a simulation program. The coupling elements used were chosen according to simulation results. Afterward, experimental circuits were established in the laboratory according to the simulation results of the designed experimental circuit. Then, breakdown voltages under composite DC and LI voltage for less uniform and non-uniform electric fields were measured with four different electrode systems for positive and negative DC voltage pre-stresses with different amplitudes. The 50% breakdown voltage was calculated using the least-squares method. Finally, 3D models were created for the electrode systems used in the experiments using the finite element method. The efficiency factors of electrode systems calculated with the FEM results were correlated with the experimental breakdown voltage results. Thus, the breakdown behavior of air under bipolar and unipolar composite voltages (CV) was investigated. In conclusion, the experimental results showed that very fast polarity change in bipolar CV causes higher electrical stress compared to unipolar CV.