Hongfei Yu

Dr. Hongfei Yu

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
17 February 2025 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
SYShunjiang Yu
Shunjiang Yu
CCChangming Chen
Changming Chen
YWYunchu Wang
Yunchu Wang
HYHongfei Yu
Hongfei Yu
CPChuanxun Pei
Chuanxun Pei
ZLZhenzhi Lin
Zhenzhi Lin
Heat storage capacity of heat network in urban integrated energy system (UIES) has the potential to significantly improve the operational flexibility of the system. To obtain the optimal UIES planning scheme, a UIES station-network cooperative optimization planning (UIES-SNCOP) method considering heat storage capacity is proposed. First, a heat network operation model under constant flow-variable temperature considering flow direction depiction is established for solving the problem that the existing model cannot be directly applied to UIES-SNCOP because the flow direction of pipeline cannot be predetermined. Then, a radial structure-oriented topology model of distribution and heat networks is developed to ensure the radiality of energy supply network while also reducing planning cost. On this basis, a UIES-SNCOP model based on information gap decision theory and stochastic optimization is constructed to realize the co-optimization of the siting and sizing of energy station and topology of distribution and heat networks. Finally, a solution method of UIES-SNCOP model based on relaxation-contraction coupled McCormick envelope is proposed for effectively improving the accuracy of solution result. The planning of UIES is conducted on an urban topology containing 55 nodes to test the performance of the proposed method, and simulation results indicate that the proposed method outperforms other existing methods in terms of reducing planning cost, ensuring radial structure of the energy supply network, utilizing heat storage capacity and enhancing solution accuracy.

14 September 2023 in Energies
Verified
Journal Article
Open access
PDF file
CXChenxuan Xu
Chenxuan Xu
WQWeiqiang Qiu
Weiqiang Qiu
LSLinjun Si
Linjun Si
TZTianhan Zhang
Tianhan Zhang
JLJun Li
Jun Li
ZLZhenzhi Lin
Zhenzhi Lin
With the promotion of carbon peaking and carbon neutrality goals and the construction of renewable-dominated electric power systems, renewable energy will become the main power source of power systems in China. Therefore, ensuring frequency stability and system security will emerge as pivotal challenges in the future development process. Created by combining a Li-ion battery and a supercapacitor, a hybrid energy storage system (HESS), which possesses robust power regulation capabilities and rapid response capabilities, holds promise for supporting the frequency stability of power systems. In this context, the assessment of the economic viability of HESSs providing multitype frequency response services becomes a critical factor in their deployment and promotion. In this paper, an economic analysis approach for a Li-ion battery–supercapacitor HESS towards a multitype frequency response is presented. First, a multitype frequency response-oriented operational mode for the HESS is designed, outlining the roles and functions of the Li-ion battery and the supercapacitor in delivering distinct services. Moreover, building upon the analysis of the power trajectory of Li-ion batteries, a lifetime model for the HESS is proposed based on the rain-flow counting method. Furthermore, considering the competitive landscape for the HESS in the frequency regulation ancillary service market, a full lifecycle economic assessment model is proposed. Finally, case studies on actual power system frequency data and PJM market data are performed to verify the effectiveness of the proposed method, and the simulation results confirm that the HESS exhibits robust performance and a competitive advantage in providing multitype frequency response services. Additionally, it demonstrates commendable economic benefits, establishing its potential as a valuable contributor to frequency response services.

29 August 2025 in IEEE Transactions on Sustainable Energy
Verified
Journal Article
Closed access
HYHongfei Yu
Hongfei Yu
SYShunjiang Yu
Shunjiang Yu
FXFucong Xu
Fucong Xu
YCYuge Chen
Yuge Chen
TZTianhan Zhang
Tianhan Zhang
ZLZhenzhi Lin
Zhenzhi Lin
The integration of renewable energy sources into power systems introduces operational challenges that can be efficiently managed through grid company-led virtual power plants (VPPs), which coordinate multiple distributed resource aggregators. To enhance VPPs’ short-term flexibility, demand-side distributed storage units can be aggregated by an energy storage aggregator (ESA) to provide leasing services of shared capacity. Given this background, an integrated framework for flexibility aggregation and power disaggregation of distributed shared energy storage (DSES) units to coordinate VPPs in the regulation market is proposed in this paper. First, a coordination scheme for DSES and VPP through ESA is proposed. Second, a state of charge (SoC) consistency-based flexibility aggregation method is established to determine an intuitive feasible region for the energy storage cluster and simplify interactions between ESA and VPP. Then, an SoC-consistent power disaggregation method, based on the geometric water-filling algorithm, is developed to effectively control DSES units in tracking VPP scheduling. Finally, case studies demonstrate that the proposed models significantly enhance VPP operations and profitability for both ESA and VPP, with DSES units more accurately tracking real-time VPP scheduling under normal and contingency conditions.

6 August 2026 in Applied Sciences
Verified
Journal Article
Open access
PDF file
HFHongyu Fang
Hongyu Fang
HYHongfei Yu
Hongfei Yu
JHJinhua Huang
Jinhua Huang
YLYuhao Liu
Yuhao Liu
JBJikai Bi
Jikai Bi
ZLZhenzhi Lin
Zhenzhi Lin
Deliberate coordinated cyber–physical attacks, which combine cyber intrusions with physical disruptions, pose growing risks to the secure and reliable operation of power systems. To identify highly disruptive coordinated cyber–physical attack strategies under pre-attack defense allocation and post-attack emergency dispatch responses, a tri-level defender–attacker–defender (DAD)-based attack strategy optimization model is proposed. First, based on the association between substation automation control systems and transmission line operation, the mechanism of breaker-tripping attacks (BTAs) through compromised digital relays in substations is investigated. Second, a tri-level DAD model is developed to optimize coordinated BTA and physical line attack strategies while accounting for pre-attack cyber and physical defense, cascading failure propagation, and post-attack emergency dispatch responses. Then, based on duality theory, network flow models, and the column-and-constraint generation (C&CG) algorithm, an iterative solution framework consisting of a defense master problem and an attack-dispatch subproblem is constructed to capture post-attack topology updates, cascading line outages, generator redispatch and load-shedding responses. Finally, the proposed method is validated using the IEEE 39 bus and IEEE 118 bus power systems. Case study results demonstrate that the proposed model identifies the most damaging coordinated cyber–physical attack strategies and that BTA-induced topology changes and cascading failure propagation significantly affect attack target selection. The proposed solution method obtains the accurate optimal objective value while reducing computational time by 92.91% for IEEE 39 bus power system, and it successfully obtains a converged solution for IEEE 118 bus power system.

1 January 2026 in IEEE Transactions on Smart Grid
Verified
Journal Article
Closed access
HYHongfei Yu
Hongfei Yu
LLLi Li
Li Li
JBJikai Bi
Jikai Bi
SYShunjiang Yu
Shunjiang Yu
YLYuhao Liu
Yuhao Liu
FWFushuan Wen
Fushuan Wen