(1) Background: Early-stage bone resorption following implant placement can significantly impact the long-term success of implants. This study evaluates whether a fully digitally planned implant position based on the E-point concept, along with guided profiling of the supracrestal complex, contributes to improved stability of peri-implant bone levels. (2) Methods: 29 implants were placed in 27 patients utilizing both immediate (Group 1; n = 19) and delayed placement (Group 2; n = 10) protocols. Implant position and emergence profile were preoperatively determined and consistently executed through guided surgery and CAD/CAM-fabricated restorations. Due to the subcrestal positioning of the implant, a corresponding bone profiler with a guide pin was used to shape the emergence profile and prevent the provisional restoration from impinging on the proximal bone. Provisional restorations were immediately placed to support the emergence profile. Bone level changes were documented radiographically over a two-year period. The first Bone-to-Implant Contact Level (∆ fBIC), change in highest approximal Bone Level (∆ haBL), and formation of an emergence profile width (WEP) were measured. (3) Results: All implants and restorations survived after two years, no significant change in first Bone-to-Implant Contact Level (∆ fBIC = 0 ± 0.02 mm), no change in highest approximal Bone Level (∆ haBL) of −0.23 mm ± 0.71 mm, and formation of an emergence profile width (WEP) averaging 0.18 ± 0.19 mm. (4) Conclusions: Despite the initial stress on the bone caused by bone profiling, guided implant placement and bone shaping, supported by an immediate provisional, have a positive effect on peri-implant bone stability.
Objectives: To compare prosthesis survival, complication-free survival, and maintenance-free survival between telescopic-crown-retained dentures (TCDs) and root-cap-retained overdentures with ball attachments (RCDs), and to evaluate associated clinical factors. Methods: This retrospective single-center cohort study included 654 unique patients, each contributing one eligible prosthesis (406 TCDs and 248 RCDs). Mean follow-up was 4.15 years for TCD and 2.75 years for RCD. Time-to-event outcomes were analyzed using Kaplan–Meier methods and multivariable Cox regression. Adjusted analyses were restricted to prostheses supported by one to three abutments. Results: Unadjusted prosthesis survival was higher for TCD (p = 0.0001), whereas prosthesis type was not clearly associated with loss after adjustment (RCD vs. TCD: HR = 1.28; 95% CI: 0.75–2.19). Single-abutment support and, in sensitivity analysis, point-like support were associated with higher loss hazards. The higher adjusted complication hazard for RCD was attenuated in sensitivity analysis. RCDs were consistently associated with earlier maintenance (average HR = 1.75; 95% CI: 1.43–2.13), with exploratory analyses suggesting a greater difference during early follow-up and among single-abutment prostheses. Conclusions: The support situation appears more relevant to prosthesis loss than the retention concept alone. RCDs show earlier first documented maintenance requirements, whereas evidence for an independent difference in complication risk is model-dependent.