Veerapandiyan Veerasamy

Dr. Veerapandiyan Veerasamy

Cybersecurity, Curtin University, Singapore, Central Singapore, Singapore
orcid

Research Focus & Metrics

Academic Career Length

9Years (2018-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
22 February 2021 in IEEE Access
Verified
Journal Article
Open access
VVVeerapandiyan Veerasamy
Veerapandiyan Veerasamy
NOOR IZZRI ABDUL WAHABNOOR IZZRI ABDUL WAHAB
NOOR IZZRI ABDUL WAHAB
MOMohammad Lutfi Othman
Mohammad Lutfi Othman
Sanjeevikumar PadmanabanSanjeevikumar Padmanaban
Sanjeevikumar Padmanaban
KSKavaskar Sekar
Kavaskar Sekar
MIMohammad Zohrul Islam
Mohammad Zohrul Islam
This paper presents the detection of High Impedance Fault (HIF) in solar Photovoltaic (PV) integrated power system using recurrent neural network-based Long Short-Term Memory (LSTM) approach. For study this, an IEEE 13-bus system was modeled in MATLAB/Simulink environment to integrate 300 kW solar PV systems for analysis. Initially, the three-phase current signal during non-faulty (regular operation, capacitor switching, load switching, transformer inrush current) and faulty (HIF, symmetrical and unsymmetrical fault) conditions were used for extraction of features. The signal processing technique of Discrete Wavelet Transform with db4 mother wavelet was applied to extract each phase's energy value features for training and testing the classifiers. The proposed LSTM classifier gives the overall classification accuracy of 91.21% with a success rate of 92.42 % in identifying HIF in PV integrated power network. The prediction results obtained from the proffered method are compared with other well-known classifiers of K-Nearest neighbor's network, Support vector machine, J48 based decision tree, and Naïve Bayes approach. Further, the classifier's robustness is validated by evaluating the performance indices (PI) of kappa statistic, precision, recall, and F-measure. The results obtained reveal that the proposed LSTM network significantly outperforms all PI compared to other techniques.

13 April 2020 in IEEE Access
Verified
Journal Article
Open access
VVVeerapandiyan Veerasamy
Veerapandiyan Veerasamy
NOOR IZZRI ABDUL WAHABNOOR IZZRI ABDUL WAHAB
NOOR IZZRI ABDUL WAHAB
RRRajeswari Ramachandran
Rajeswari Ramachandran
MOMohammad Lutfi Othman
Mohammad Lutfi Othman
HHhashim hizam
hashim hizam
JKJeevitha Satheesh Kumar
Jeevitha Satheesh Kumar
This paper presents the automatic load frequency control (ALFC) of two-area multisource hybrid power system (HPS). The interconnected HPS model consists of conventional and renewable energy sources operating in disparate combinations to balance the generation and load demand of the system. In the proffered work, the stability analysis of nonlinear dynamic HPS model was analyzed using the Hankel method of model order reduction. Also, an attempt was made to apply cascade proportional integral – proportional derivative (PI-PD) control for HPS. The gains of the controller were optimized by minimizing the integral absolute error (IAE) of area control error using particle swarm optimization–gravitational search algorithm (PSO-GSA) optimization technique. The performance of cascade control was compared with other classical controllers and the efficiency of this approach was studied for various cases of HPS model. The result shows that the cascade control produced better transient and steady state performances than those of the other classical controllers. The robustness analysis also reveals that the system overshoots/undershoots in frequency response pertaining to random change in wind power generation and load perturbations were significantly reduced by the proposed cascade control. In addition, the sensitivity analysis of the system was performed, with the variation in step load perturbation (SLP) of 1% to 5%, system loading and inertia of the system by ±25% of nominal values to prove the efficiency of the controller. Furthermore, to prove the efficiency of PSO-GSA tuned cascade control, the results were compared with other artificial intelligence (AI) methods presented in the literature. Further, the stability of the system was analyzed in frequency domain for different operating cases.

1 January 2022 in Measurement
Verified
Journal Article
Closed access
KSK.S.V. Swarna
K.S.V. Swarna
AVArangarajan Vinayagam
Arangarajan Vinayagam
MAM. Belsam Jeba Ananth
M. Belsam Jeba Ananth
PKP. Venkatesh Kumar
P. Venkatesh Kumar
VVVeerapandiyan Veerasamy
Veerapandiyan Veerasamy
PRPadmavathi Radhakrishnan
Padmavathi Radhakrishnan

2 September 2020 in IEEE Access
Verified
Journal Article
Open access
AIAndrew Xavier Raj Irudayaraj
Andrew Xavier Raj Irudayaraj
NOOR IZZRI ABDUL WAHABNOOR IZZRI ABDUL WAHAB
NOOR IZZRI ABDUL WAHAB
MUMallapu Gopinath Umamaheswari
Mallapu Gopinath Umamaheswari
MRMohd Amran Mohd Radzi
Mohd Amran Mohd Radzi
NSNasri Bin Sulaiman
Nasri Bin Sulaiman
RRRajeswari Ramachandran
Rajeswari Ramachandran
The large-scale penetration of intermittent renewable energy (RE) sources such as wind and solar power generation may cause a problem of frequency aberration, power quality and instability to the system. This occurs when the load frequency control of interconnected system is unable to compensate the power balance between generation and load demand. To overcome these issues, this paper proposes a method to analyze the frequency stability of Hybrid Power System (HPS) through adaptive intelligent control techniques for delivering reliable power supply under the stochastic nature of RE and load demand. A recently developed physics-inspired Atom Search Optimization algorithm was applied for tuning the parameters of Fractional Order Proportional-Integral-Derivative controller for Automatic Load Frequency control of HPS. In addition, an effort was made to analyze the frequency stability of HPS using Matignon’s theorem. The interconnected HPS consists of reheat thermal power system, RE sources such as wind and solar thermal power generation associated with energy storage devices namely aqua electrolyzer, fuel cell and electric vehicle. The gain and fractional terms of the controller were obtained by minimizing the Integral Time Absolute Error of interconnected system. The robustness of ASO-tuned FOPID controller is tested on two-area HPS that was modelled using MATLAB/Simulink. The results obtained were then compared with other fractional order and classical integer order controllers. From the simulation results, it is inferred that the proposed ASO-tuned FOPID controller gives superior transient and steady-state response compared with other controllers. Moreover, the self-adaptiveness and robustness of the controller was validated to account for the change in RE power generations and system parameters. Furthermore, the effectiveness of the method is proved by comparing its performance with the recent literature works. The real-time applicability of proffered controller is validated in hardware-in-the-loop simulation using Real Time Digital Simulator.

3 January 2020 in Energies
Verified
Journal Article
Open access
PDF file
EAElhadi Aker
Elhadi Aker
MOMohammad Lutfi Othman
Mohammad Lutfi Othman
VVVeerapandiyan Veerasamy
Veerapandiyan Veerasamy
IAIshak Bin Aris
Ishak Bin Aris
NOOR IZZRI ABDUL WAHABNOOR IZZRI ABDUL WAHAB
NOOR IZZRI ABDUL WAHAB
HHhashim hizam
hashim hizam
This paper presents the methodology to detect and identify the type of fault that occurs in the shunt compensated static synchronous compensator (STATCOM) transmission line using a combination of Discrete Wavelet Transform (DWT) and Naive Bayes (NB) classifiers. To study this, the network model is designed using Matlab/Simulink. Different types of faults, such as Line to Ground (LG), Line to Line (LL), Double Line to Ground (LLG) and the three-phase (LLLG) fault, are applied at disparate zones of the system, with and without STATCOM, considering the effect of varying fault resistance. The three-phase fault current waveforms obtained are decomposed into several levels using Daubechies (db) mother wavelet of db4 to extract the features, such as the standard deviation (SD) and energy values. Then, the extracted features are used to train the classifiers, such as Multi-Layer Perceptron Neural Network (MLP), Bayes and the Naive Bayes (NB) classifier to classify the type of fault that occurs in the system. The results obtained reveal that the proposed NB classifier outperforms in terms of accuracy rate, misclassification rate, kappa statistics, mean absolute error (MAE), root mean square error (RMSE), percentage relative absolute error (% RAE) and percentage root relative square error (% RRSE) than both MLP and the Bayes classifier.

1 October 2021 in Sustainable Energy Technologies and Assessments
Verified
Journal Article
Closed access
SSS.T Suganthi
S.T Suganthi
AVArangarajan Vinayagam
Arangarajan Vinayagam
VVVeerapandiyan Veerasamy
Veerapandiyan Veerasamy
ADA. Deepa
A. Deepa
MAMohamed Abouhawwash
Mohamed Abouhawwash
MTMariammal Thirumeni
Mariammal Thirumeni