Jeevitha Kandasamy

Jeevitha Kandasamy

Auto-generated profile, based on publicly available information

Jeevitha Kandasamy

Alliance University

Research Focus & Metrics

Academic Career Length

7Years (2020-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
13 April 2020 in IEEE Access
Verified
Journal Article
Open access
VVVeerapandiyan Veerasamy
Veerapandiyan Veerasamy
NOOR IZZRI ABDUL WAHABNOOR IZZRI ABDUL WAHAB
NOOR IZZRI ABDUL WAHAB
RRRajeswari Ramachandran
Rajeswari Ramachandran
MOMohammad Lutfi Othman
Mohammad Lutfi Othman
HHhashim hizam
hashim hizam
JKJeevitha Satheesh Kumar
Jeevitha Satheesh Kumar
This paper presents the automatic load frequency control (ALFC) of two-area multisource hybrid power system (HPS). The interconnected HPS model consists of conventional and renewable energy sources operating in disparate combinations to balance the generation and load demand of the system. In the proffered work, the stability analysis of nonlinear dynamic HPS model was analyzed using the Hankel method of model order reduction. Also, an attempt was made to apply cascade proportional integral – proportional derivative (PI-PD) control for HPS. The gains of the controller were optimized by minimizing the integral absolute error (IAE) of area control error using particle swarm optimization–gravitational search algorithm (PSO-GSA) optimization technique. The performance of cascade control was compared with other classical controllers and the efficiency of this approach was studied for various cases of HPS model. The result shows that the cascade control produced better transient and steady state performances than those of the other classical controllers. The robustness analysis also reveals that the system overshoots/undershoots in frequency response pertaining to random change in wind power generation and load perturbations were significantly reduced by the proposed cascade control. In addition, the sensitivity analysis of the system was performed, with the variation in step load perturbation (SLP) of 1% to 5%, system loading and inertia of the system by ±25% of nominal values to prove the efficiency of the controller. Furthermore, to prove the efficiency of PSO-GSA tuned cascade control, the results were compared with other artificial intelligence (AI) methods presented in the literature. Further, the stability of the system was analyzed in frequency domain for different operating cases.

1 January 2026 in International Journal of Distributed Sensor Networks
Verified
Journal Article
Open access
ASArunkumar Subramanian
Arunkumar Subramanian
SPSatheesh Kumar Palanisamy
Satheesh Kumar Palanisamy
SSSathishkumar N Sathishkumar
Sathishkumar N Sathishkumar
SMSheila Mahapatra
Sheila Mahapatra
JKJeevitha Kandasamy
Jeevitha Kandasamy
SSSachin Shrestha
Sachin Shrestha
Industrial wireless sensor networks (IWSNs) have to continuously monitor process and transmit signals from the industrial environment with strict energy limitations. The impact of energy depletion–induced signal interruptions is significant on the reliability of tasks and the real‐time industrial operation. To overcome this challenge, a signal‐aware reliant task scheduling scheme (RTSS) for rechargeable IWSNs with energy harvesting mechanisms is proposed in this paper. The RTSS is based on a research gap–driven principle: For every researched limitation, a corresponding innovation is developed: a real‐time signal–energy coupling model that continuously monitors signal traffic density and node energy levels during periods of active signal processing; a knowledge‐learning mechanism that dynamically classifies nodes as available, idle, or low‐energy, allowing for proactive task allocation decisions without reliance on static energy assumptions; a dynamic task reallocation strategy that seamlessly transfers tasks from energy‐degraded nodes to available alternate processing nodes before signal interruptions; and an embedded energy harvesting module that recharges low‐energy nodes during idle processing periods to ensure long‐term network operability. The RTSS continuously updates its knowledge base over a scheduling interval, thereby enhancing the accuracy of the scheduling over time and continuity of its signal. The evaluation through simulation with a real‐world computer numerical control (CNC) machine dataset of 200 tasks and 60 sensor nodes verifies the superiority of the proposed RTSS over the state‐of‐the‐art RTSS baselines: joint power function–network‐in‐box (JPF‐NIB), low‐complexity channel resource allocation algorithm (LCCRAA), and enhanced energy optimization model (EEOM), in all critical performance metrics. In particular, the RTSS yields improvements of 10.48%, 10.87%, and 10.38% in the signal awareness task scheduling rate, successful signal delivery ratio, and energy harvesting rate, respectively, and reduces the average energy consumption by 8.63% and signal interruptions by 13.66% compared with the best performing baseline. The findings demonstrate the adaptability, scalability, and reliability of the RTSS for handling energy constraints in industrial applications with the requirement of uninterrupted signal processing and task execution.

7 May 2026 in Energy Exploration & Exploitation
Verified
Journal Article
Open access
JKJeevitha Kandasamy
Jeevitha Kandasamy
SMSheila Mahapatra
Sheila Mahapatra
SSSachin Shrestha
Sachin Shrestha
Interconnected microgrid systems (IMSs) provide a strong foundation for improving the effectiveness of multiple distributed energy resources (DERs); however, operating numerous DERs in tandem remains a major obstacle. This paper presents a distributed control strategy (DCS) based on a federated learning (FL) fuzzy-optimised recurrent neural network (F-RNN), which uses an adaptive fractional-order proportional–integral–derivative (FOPID) controller to regulate frequency deviation. The control problem is formulated as a fractional-order consensus control strategy, using a Lyapunov-based framework that captures the dynamic behaviour of the RNN. Controller parameters are obtained from the dynamics of the energy function to update neuronal states, whereas FL is used during training to enhance network performance through improved information exchange. The proposed controller was demonstrated in Simulation/MATLAB and in real-time OPAL-RT Hardware-In-The-Loop under various conditions like load-demand uncertainty, stochastic loads, presence or absence of communication delay, communication link failure and source loss. Results based on quantitative analysis show that the proposed controller will be superior to the conventional controllers. More specifically, the proposed controller provides up to 73% reduction in integral absolute error, 33% lowering of the integral time absolute error, and greater than 70% improvement in integral time-weighted squared error as compared to the RNN–FOPID controller. The settling time has been improved from approximately 6.1 s down to 3.0 s with the peak frequency deviation being reduced by nearly 80%, illustrating the improved damping and transient performance of the proposed method.

1 January 2026 in IEEE Canadian Journal of Electrical and Computer Engineering
Verified
Journal Article
Closed access
JKJeevitha Kandasamy
Jeevitha Kandasamy
SMSheila Mahapatra
Sheila Mahapatra
FHFahima Hajjej
Fahima Hajjej

1 January 2026 in Electronics Letters
Verified
Journal Article
Open access
SPSatheesh Kumar Palanisamy
Satheesh Kumar Palanisamy
JKJeevitha Kandasamy
Jeevitha Kandasamy
SSSathishkumar N Sathishkumar
Sathishkumar N Sathishkumar
SSSachin Shrestha
Sachin Shrestha
This letter proposes A‐CQFOA, an adaptive chaotic quantum‐inspired fruit fly optimisation framework for multi‐objective feature selection coupled with CNN, LSTM and Bi‐LSTM sentiment classifiers. It unifies a logistic chaotic map and quantum rotation operator within a single FOA‐based selector, with a classifier‐coupled fitness function optimising accuracy, feature compactness and prediction consistency, and an adaptive stagnation‐aware chaos‐decay mechanism. Over 30 independent 10‐fold CV runs on Sentiment140 (1.6 M tweets), SST‐2 (67k reviews) and Telecom Twitter (22k opinions), A‐CQFOA obtains mean accuracies of 0.9267, 0.9412 and 0.9328—gains of +3.17–3.28% over PSO while reducing features by 35%–45%. Open‐set AUC = 0.997 and >94% few‐shot accuracy (5 samples/class), all at p < 0.01.