An accurate measurement of bubble shape and size has a significant value in understanding the behavior of bubbles that exist in many engineering applications. Past studies usually use one or two cameras to estimate bubble volume, surface area, among other parameters. The 3D bubble shape and rotation angle are generally not available in these studies. To overcome this challenge and obtain more detailed information of individual bubbles, a 3D imaging system consisting of four high-speed cameras is developed in this paper, and the space carving method is used to reconstruct the 3D bubble shape based on the recorded high-speed images from different view angles. The proposed method can reconstruct the bubble surface with minimal assumptions. A benchmarking test is performed in a 3 cm × 1 cm rectangular channel with stagnant water. The results show that the newly proposed method can measure the bubble volume with an error of less than 2% compared with the syringe reading. The conventional two-camera system has an error around 10%. The one-camera system has an error greater than 25%. The visualization of a 3D bubble rising demonstrates the wall influence on bubble rotation angle and aspect ratio. This also explains the large error that exists in the single camera measurement.
3 June 2022 in Journal of Orthopaedic Surgery and Research
Background: The treatments for trochanteric fractures try to regain early mobility and limit morbidity and risk of reoperations. The most currently used dynamic hip screw (DHS) and the proximal femoral nail (PFN) are both with pros and cons. We aimed to assess the comparative effectiveness of these interventions for trochanteric fractures by evaluating the surgical performance and postoperative outcomes. Methods: PubMed, Web of Science and Cochrane Central Register were searched for RCTs comparing DHS and PFN for trochanteric fractures. All selected studies and the risk of bias were assessed. Clinical data including operative time, intraoperative blood loss, intraoperative fluoroscopy time, successful closed reduction and complications like nonunion, implant failure and reoperation were recorded. Random-effects models were used in Review Manager software, and GRADE was applied for the interpretation of the evidence. Results: From 286 identified trials, twelve RCTs including 1889 patients were eligible for inclusion; six RCTs directly comparing DHS with PFN, while other six compared DHS with proximal femoral nail antirotation (PFNA). Compared to DHS, PFN had shorter operative time and led to less intraoperative blood loss. However, DHS need less intraoperative fluoroscopy time than PFN. No difference was seen for the achievement of closed reduction. For risk of postoperative complications, no difference was seen between PFN and DHS for non-union, risk of implant failure and revision surgery. Conclusions: PFN(A) resulted in a shorter operative time and less intraoperative blood loss compared to DHS. However, no difference was seen for postoperative complications. Trial registration PROSPERO: CRD42021239974.
19 January 2018 in Measurement Science and Technology
In this paper, a compact x-ray densitometry system consisting of a 50 kV, 1 mA x-ray tube and several linear detector arrays is developed for two-phase flow measurement. The system is capable of measuring void fraction and velocity distributions with a spatial resolution of 0.4 mm per pixel and a frequency of 1000 Hz. A novel measurement model has been established for the system which takes account of the energy spectrum of x-ray photons and the beam hardening effect. An improved measurement accuracy has been achieved with this model compared with the conventional log model that has been widely used in the literature. Using this system, void fraction and velocity distributions are measured for a bubbly and a slug flow in a 25.4 mm I.D. air–water two-phase flow test loop. The measured superficial gas velocities show an error within ±4% when compared with the gas flowmeter for both conditions.
1 January 2017 in International Journal of Multiphase Flow
Various techniques have been developed in the past to measure the different parameters in two-phase flow. Among them, the multi-sensor conductivity probe is one of the most commonly used techniques because of its good overall performance. Recently, more advanced techniques, such as high-speed optical imaging and fast x-ray densitometry, have matured and become easily accessible. The main objective of this work is to compare and integrate these different techniques, to achieve a more accurate and complete measurement of two-phase flow. In this study, a double-sensor conductivity probe is used to measure the local time-averaged parameters along the radial direction of a 2.54 cm ID round pipe. An x-ray densitometry system is used to measure the chordal averaged void fraction and gas velocity. A high-speed camera system is employed to provide a visualization of the two-phase flow structure and obtain the line-averaged gas velocity. The unique advantages and main uncertainties of these three techniques are analyzed by considering their measuring principles and possible issues in practical measurements. From this, a method is developed to integrate the data obtained by the optical and x-ray systems into the probe signal processing. Better accuracy can be achieved using this method for various local two-phase flow parameters, including the void fraction, bubble velocity and superficial gas velocity, compared to the original probe measurements.