春静 岳

Ms. 春静 岳


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
23 August 2026 in Batteries
Verified
Journal Article
Open access
PDF file
春岳春静 岳
春静 岳
SZShupeng Zhao
Shupeng Zhao
XSXiaokang Shi
Xiaokang Shi
HYHui Yang
Hui Yang
RZRui Zhu
Rui Zhu
YZYulong Zhang
Yulong Zhang
Electrochemical impedance spectroscopy (EIS) resolves the internal physicochemical processes of lithium-ion batteries across timescales—from ohmic conduction through charge-transfer kinetics to solid-state diffusion. Despite this analytical power, EIS deployment remains largely confined to laboratory electrochemical workstations that are bulky, expensive, and incapable of online multi-cell operation under dynamic DC bias conditions. This study presents a multi-channel EIS measurement device that simultaneously addresses three requirements for practical battery diagnostics: workstation-grade measurement accuracy, multi-cell synchronous acquisition, and tolerance to the DC bias voltage present across battery terminals during operation. The device employs a master–slave distributed architecture: each slave unit is built around the DNB1101 battery-dedicated impedance measurement chip with a Kelvin four-wire sensing configuration, while the STM32F407-based master controller coordinates measurement scheduling and data communication under FreeRTOS. A four-channel slave board with a differential daisy-chain communication topology and hardware broadcast trigger mechanism supports multi-cell synchronous acquisition. The device operates over a frequency range of 0.01 Hz to 5620 Hz with logarithmic spacing, and a C#-based host application provides real-time Nyquist and Bode visualization along with MATLAB R2024a-based post-processing for outlier rejection and data smoothing. Validation was conducted using Panasonic NCR18650 ternary (NCA) and LiFePO4 (LFP) 18650 cells, benchmarked against a CorrTest CS350 electrochemical workstation at SOC = 40% and 25 °C. The device achieves a maximum impedance magnitude error of 1.55% and a maximum phase error of 1.22%. Equivalent circuit model fitting via ZSimpWin yields parameter differences below 1% between the device and the reference workstation. Under online conditions with a 3.6 V DC bias, the impedance measurement deviation of a 20 mΩ precision resistor remains below 0.69% across the full frequency range. Multi-channel synchronous measurements across four cells demonstrate inter-channel amplitude variance below 2.13%. Cross-chemistry validation with LiFePO4 cells yields magnitude and phase errors below 0.92%. These results demonstrate that the proposed device provides laboratory-grade EIS accuracy with multi-channel, online, and cross-chemistry capabilities, offering a practical platform for integrating EIS-based diagnostics into next-generation battery management systems.