With the increasing proportion of distributed generators (DGs), distribution networks usually include grid forming (GFM) and grid following (GFL) converters. However, the incompatibility of dynamic performance caused by different control methods of the GFM and GFL converters may bring instability problems and power quality risks to the distribution network. To solve this issue, the models of the GFM and GFL converters are established first to lay a good foundation for stability analysis and power quality improvement control. On this basis, an inner loop parameters design scheme is developed for GFM converters based on the D-Partition method, which facilitates the stability boundary characterization. Meanwhile, a current injection strategy is proposed to enhance the voltage support capacity of the GFL converter during grid faults. Moreover, for the distribution network with multi-converters, a compensation current control based on the analytic hierarchy process and coefficient of variation is proposed to ensure a balance between minimal capacity and optimal power quality. In this manner, DGs can be plug-and-play without considering stability and power quality issues. Finally, the effectiveness of the proposed strategy is validated with simulation results.
Parallel converter operation enables flexible capacity expansion of energy-storage power conversion systems. However, parallel converter interactions, filter-inductor saturation, and grid-strength variations increase the risk of resonance instability. The measured current-inductance characteristic is incorporated into an operating-point-dependent closed-loop Norton model. The grid current of an individual converter is decomposed into self-reference, parallel converter coupling, and grid-voltage-disturbance responses. It reveals that converter-side inductance attenuation shifts the internal and parallel resonances to higher frequencies and increases resonance-instability risk, whereas converter number and grid impedance primarily reshape the parallel resonance. A coordinated active-damping method is then developed: PCC voltage feedforward weakens common-network interaction, and capacitor-voltage feedback increases local LCL-filter damping. Simulation and experimental results validate the feasibility and effectiveness of the proposed control method. Experiments with two parallel converters validated the proposed control method. Stable transient current responses were achieved during a simultaneous current-reference step from 50 to 120 A, while the grid-current THD and power-sharing deviation remained below 3% and 5%, respectively.