Islanding detection is the essential basis for the safety and protection of dc microgrids. Due to the advantages of rapid detection speed and small nondetection zone, the positive feedback islanding detection technique has attracted much interest in recent years. The implementation of a positive feedback loop facilitates the islanding detection for dc microgrids, but it may reduce the system stability margin at the grid-connected state. In this article, the dc output impedance model of voltage source converter and distributed generators are developed to reveal the dynamic interactions and instability mechanism accurately between the two subsystems considering the impact of islanding detection with voltage positive feedback of selected frequency (VPFOSF). Then, the stability region of the interconnected system based on the output admittance model is derived to guide the design method of the damping compensator. Moreover, a grid-current-based active-damping control scheme is further proposed to mitigate instability caused by the VPFOSF loop. Thus, the conflict among islanding detection rapidity, power quality, and grid-connected system stability is effectively addressed. In the end, both the simulations and experimental results are provided to validate the effectiveness of the proposed control method.
28 February 2025 in IEEE Transactions on Industrial Informatics
To improve system flexibility and reliability, mobile energy storage (MES) is treated as a unified dispatching resource of the active distribution network (ADN) to participate in operation optimization and power supply recovery. However, the coordinated optimization of MES with ADN network reconfiguration and voltage regulation is neglected in current studies. Especially, there exists blank research on ADN and MES as independent stakeholders. Therefore, a coordinated operation strategy based on the Stackelberg game for ADN and MES is proposed. Considering multitime period dynamic reconfiguration, voltage regulation, and their joint optimization with MES, the ADN as a leader, makes a tradeoff between expected profits and reliability to formulate reasonable prices for MES. As a follower, MES models energy transfer characteristics based on the space–time network and actively participates in the operation optimization of ADN by responding to the price decision to increase revenue. Following that, Karush–Kuhn–Tucker conditions are used to transform the two-layer optimization model based on the Stackelberg game into a single-layer mixed integer linear programming problem for solution. Finally, simulations on an improved IEEE-33 bus system validate the proposed strategy, which saves 2.2% of total social costs and reduces 6% of the voltage deviation.
20 September 2024 in IEEE Transactions on Power Electronics
This article proposes a bidirectional modular multilevel resonant dc converter (BMMRDC) and its power flow control strategy for medium-voltage dc to low-voltage dc distribution network First, a brief description of the BMMRDC topology structure is provided, followed by a detailed investigation of its operational principles under different operating modes. Then, the voltage gain model is studied, and the relationship between the transferred power and the operating frequency is precisely built. On this basis, a bidirectional power control strategy is proposed to adjust power flexibly by regulating the switching frequency. Furthermore, the soft-switching behaviors of the medium-voltage side and low-voltage side devices are analyzed to guide the parameter design of the converter, enabling soft-switching operation under a wide range of operating conditions. Finally, a downscaled BMMRDC prototype is constructed to validate the feasibility of the BMMRDC topology and the proposed control strategy.
17 May 2023 in IEEE Transactions on Industry Applications
For better utilization of DC-inherent renewable energy with high penetration and fluctuation, the solid-state transformer (SST)-based power systems have received great attention and arose increasing demand for grid supports and power management. Given the plug-and-play function of distributed renewable energy and loads, the economical and balanced power allocation as well as the flexible seamless transition among different operation modes are not considered comprehensively in existing studies. Therefore, distributed power management and adaptive coordinated control strategy are proposed for SST-interfaced power systems. 1) The application of SST as an alternative to multiple converters to interface the high-voltage grid (HG) and hybrid AC/DC microgrids (MGs) can reduce system communication. Compared with traditional transformers, the controllability and intelligence of SST-enabled power systems are improved. 2) The flexible seamless transition and adaptive coordinated control among HG-connected mode, MG interconnected mode and islanding mode are realized to adapt to different fault conditions. 3) Considering system operation limits, the economical and balanced power allocation is realized accurately, and the voltage quality is effectively ensured in various operation modes. Finally, the feasibility and effectiveness of the proposed system and control strategy are tested on the OPAL-RT-based platform.
24 June 2024 in IEEE Transactions on Power Electronics
The grid forming (GFM) converter may undesirably output a higher current during the recovery stage than fault duration due to its transient angle swing, which would cause the power devices to face the risk of overcurrent or even damage in both the fault stage and the recovery stage. In this letter, the current power angle plane is presented for the current trajectory description and the mechanism of the recovery overcurrent (ROC) issue is revealed through the proposed concept of critical recovery angle (CRA). On top of that, the power angle relationship in the critical ROC state is described in detail and the ROC boundary is further characterized accurately. Moreover, an analytical calculation method of CRA is proposed to identify whether the ROC phenomenon occurs, which is well validated by a series of experiments. The proposed method depicts the inherent relationship between the current behavior and power angle motion of GFM converters quantitatively and intuitively, and it may provide some new insights into the transient analysis and control optimization of GFM converters.
11 September 2023 in IEEE Journal of Emerging and Selected Topics in Power Electronics
Islanding detection based on current disturbance of selected frequency is gaining widespread acceptance in dc microgrids due to its high detecting accuracy and good power quality. However, the selected static disturbance frequency at a specific operating state causes the expansion of the non-detection zone (NDZ) and the decrease of the detection speed under different system power conditions. In this paper, the sensitivity model of current perturbation is developed to intuitively reveal the mechanism of oscillation frequency shift and the occurrence of the NDZ. Then, the theoretical resonant frequency is derived to analyze the frequency shift range with the consideration of system power changing, which provides the NDZ boundaries accurately. Moreover, an islanding detection method (IDM) with the adaptive resonant frequency is proposed to provide zero NDZ and fast detection speed by dynamically selecting the most sensitive frequency in different power operating cases. Thus, the conflict between the NDZ and detection speed is effectively addressed. Finally, the effectiveness of the proposed IDM is validated by both the simulations and experimental results.