Measuring the mass and Center of Gravity (CG) of rigid bodies with a multi-point weighing method is widely used nowadays. Traditional methods usually include two parts with a certain location, i.e., a fixed platform and a mobile platform. In this paper, a novel structure is proposed to adjust the mobile platform for eliminating side forces which may load on the load cells. In addition, closed-form equations are formulated to evaluate the performance of the structure, and transformation matrices are used to estimate the characteristics of the structure. Simulation results demonstrate that repeatability of the proposed structure is higher than the traditional one and there are no side forces. Moreover, the measurement results show that the relative error of mass was within 0.05%, and the error of CG was within ±0.3 mm. The structure presented in this paper provides a foundation for practical applications.
The accurate measurement of aircraft mass properties, such as the mass, centroid, and moment of inertia (MOI), plays a key role in the precise control of aircraft. In order to obtain high-precision information on the parameters of the mass, centroid, and MOI of an aircraft using a single instrument, an integrated mass property measurement system was developed in this study by analyzing and comparing the latest technologies, especially the function-switching device, which switches the measurement states between the center of mass and the MOI. The purpose of mass property measurement was achieved through single clamping. In addition, the system has strong versatility and expansion and can be used with different tooling or adapter rings to measure the mass properties of aircraft with different shapes. In this paper, the main mechanical structure of the measurement system, the measurement method of relevant mass parameters, and the solution method of the transformation matrix are introduced, and the standard parts and the aircraft were verified experimentally. The test results showed that the mass measurement accuracy was 0.03%, the centroid measurement error was within ±0.2 mm, and the measurement accuracy of the MOI was within 0.2%, all of which meet the high-precision measurement requirements for the mass properties.
Structured-light technique is an effective method for indoor 3D measurement, but it is hard to obtain ideal results outdoors because of complex illumination interference on sensors. This paper presents a 3D vision measurement method based on digital image processing to improve resistance to noise of measuring systems, which ensuresnormal operation of a structured-light sensor in the wild without changing its components, and the method is applied in 3D reconstruction of snow sculpture. During image preprocessing, an optimal weight function is designed based on noise classification and minimum entropy, and the color images are transformed into monochromatic value images to eliminate most environmental noise. Then a Decision Tree Model (DTM) in a spatial-temporal context of video sequence is used to extract and track stripe. The model is insensitive to stubborn noise and reflection in the images, and the result of the model after coordinate transformation is a 3D point cloud of the corresponding snow sculpture. In experimental results, the root mean square (RMS) error and mean error are less than 0.722 mm and 0.574 mm respectively, showing that the method can realize real-time, robust and accurate measurement under a complex illumination environment, and can therefore provide technical support for snow sculpture 3D measurement.
The accurate measurement of mass and centroid is indispensable for accurate control of aircraft. In order to eliminate the influence of assembly error and product pose error on the measurement results, a multi-station measurement idea that can self-compensate for the geometric parameter error is proposed in this paper based on. At the same time, the kinematic model of the mechanical structure of the measurement equipment is established to prove the effectiveness of the structure in error compensation theoretically, and the experimental verification of the standard part and aircraft is carried out. The test results show that the measurement results using the idea of the multi-station compensation measurement are significantly better than those of the more common methods, with the mass measurement accuracy of 0.03% and the centroid error within ±0.15 mm, meeting the requirement of high precision measurement for the mass properties.
To detect underwater sound-generating targets, a water surface acoustic wave laser interference and signal demodulation technique is proposed in this paper. The underlying principle of this technique involves casting a laser beam onto the water surface disturbed by an underwater acoustic source and creating interference between lights reflected by the surface and reference lights. A data acquisition and processing system was employed to obtain water surface acoustic wave information from the interference signals by means of demodulation, thus allowing detection of the underwater target. For the purpose of this study, an interference detection platform was set up in an optical dark chamber. High-frequency water surface fluctuations were introduced in the reference optical path as the phase generated carriers to create laser interference signals in two different paths, which received demodulation based on an improved arc tangent demodulation algorithm and characteristic ratio algorithm, respectively, in view of their different frequencies. Water surface wave information was then derived from such low-frequency and high-frequency signals. According to test results, in the frequency range of 200 Hz–10 kHz, the frequency detection accuracy was better than 1 Hz. The amplitude measurements exhibited high repeatability, with a standard deviation lower than 2.5 nm. The theory proposed in this paper is therefore experimentally verified with good results.
A laser interferometry technique is developed to detect water surface capillary waves caused by an impinging acoustic pressure field. The frequency and amplitude of the water surface capillary waves can be estimated from the local signal data at some special points of the phase modulated interference signal, which is called the turning points. Demodulation principles are proposed to explain this method. Experiments are conducted under conditions of different intensity and different frequency driving acoustic signals. The results show the local signal data analysis can effectively estimate the amplitude and frequency of water surface capillary waves.2017-04-142017-05-09