Xiaoquan Yang

Prof. Dr. Xiaoquan Yang


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
2 October 2013 in Optics Express
Verified
Journal Article
Closed access
PDF file
HWHui Wang
Hui Wang
XYXiaoquan Yang
Xiaoquan Yang
YLYanyan Liu
Yanyan Liu
BJBowen Jiang
Bowen Jiang
QLQingming Luo
Qingming Luo
We developed a new reflection-mode optical-resolution photoacoustic microscopy (OR-PAM) based on the cooperation of a reflective objective and an ultrasonic transducer. The reflective objective is used to produce nearly diffraction-limited optical focusing, and the excited ultrasound waves are then directly detected by an ultrasonic transducer that was placed in the central cone of the objective. This new design avoids the coupling between optical focusing and ultrasound transmission in the reflection mode. Moreover, the proposed system is able to provide lateral resolution of 1.2 μm at 580 nm, penetration depth of 0.9 mm in biological tissues, and a work distance of 6.0 mm. We present in vivo imaging of the microvasculature in mouse ears and in vitro imaging of red blood cells (RBCs), which demonstrate the capability of the system to study microcirculation.

1 January 2022 in Science Bulletin
Verified
Journal Article
Open access
CZCan Zhou
Can Zhou
XYXiaoquan Yang
Xiaoquan Yang
SWShihao Wu
Shihao Wu
QZQiuyuan Zhong
Qiuyuan Zhong
TLTing Luo
Ting Luo
HGHui Gong
Hui Gong
To decipher the organizational logic of complex brain circuits, it is important to chart long-distance pathways while preserving micron-level accuracy of local network. However, mapping the neuronal projections with individual-axon resolution in the large and complex primate brain is still challenging. Herein, we describe a highly efficient pipeline for three-dimensional mapping of the entire macaque brain with subcellular resolution. The pipeline includes a novel poly-N-acryloyl glycinamide (PNAGA)-based embedding method for long-term structure and fluorescence preservation, high-resolution and rapid whole-brain optical imaging, and image post-processing. The cytoarchitectonic information of the entire macaque brain was acquired with a voxel size of 0.32 μm × 0.32 μm × 10 μm, showing its anatomical structure with cell distribution, density, and shape. Furthermore, thanks to viral labeling, individual long-distance projection axons from the frontal cortex were for the first time reconstructed across the entire brain hemisphere with a voxel size of 0.65 μm × 0.65 μm × 3 μm. Our results show that individual cortical axons originating from the prefrontal cortex simultaneously target multiple brain regions, including the visual cortex, striatum, thalamus, and midbrain. This pipeline provides an efficient method for cellular and circuitry investigation of the whole macaque brain with individual-axon resolution, and can shed light on brain function and disorders.

6 May 2015 in Optics Express
Verified
Journal Article
Open access
PDF file
KWKan Wang
Kan Wang
QWQun Wang
Qun Wang
Qingming LuoQingming Luo
Qingming Luo
XYXiaoquan Yang
Xiaoquan Yang
Fluorescence molecular tomography (FMT), an in vivo noninvasive imaging technology, can provide localization and quantification information for deep fluorophores. Light at wavelengths in the near-infrared (NIR-I) window from 650 nm to 950 nm has conventionally been chosen for FMT. In this study, we introduced longer NIR wavelengths within the 1100 nm to 1400 nm range, known as the “second NIR spectral window” (NIR-II). A singular-value analysis method was used to demonstrate the utility and advantages of using the NIR-II for FMT, and experiments showed an improvement in the spatial resolution in phantom studies.

6 January 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
DYDongmei Yan
Dongmei Yan
ZZZhihong Zhang
Zhihong Zhang
Qingming LuoQingming Luo
Qingming Luo
XYXiaoquan Yang
Xiaoquan Yang
With the development of hybrid imaging scanners, micro-CT is widely used in locating abnormalities, studying drug metabolism, and providing structural priors to aid image reconstruction in functional imaging. Due to the low contrast of soft tissues, segmentation of soft tissue organs from mouse micro-CT images is a challenging problem. In this paper, we propose a mouse segmentation scheme based on dynamic contrast enhanced micro-CT images. With a homemade fast scanning micro-CT scanner, dynamic contrast enhanced images were acquired before and after injection of non-ionic iodinated contrast agents (iohexol). Then the feature vector of each voxel was extracted from the signal intensities at different time points. Based on these features, the heart, liver, spleen, lung, and kidney could be classified into different categories and extracted from separate categories by morphological processing. The bone structure was segmented using a thresholding method. Our method was validated on seven BALB/c mice using two different classifiers: a support vector machine classifier with a radial basis function kernel and a random forest classifier. The results were compared to manual segmentation, and the performance was assessed using the Dice similarity coefficient, false positive ratio, and false negative ratio. The results showed high accuracy with the Dice similarity coefficient ranging from 0.709 ± 0.078 for the spleen to 0.929 ± 0.006 for the kidney.

19 April 2018 in Journal of Nanobiotechnology
Verified
Journal Article
Open access
PDF file
XZXiao-Shuai Zhang
Xiao-Shuai Zhang
YXYang Xuan
Yang Xuan
XYXiaoquan Yang
Xiaoquan Yang
KCKai Cheng
Kai Cheng
RZRuo-Yun Zhang
Ruo-Yun Zhang
Yuan-di ZhaoYuan-di Zhao
Yuan-di Zhao
Ag2S has the characteristics of conventional quantum dot such as broad excitation spectrum, narrow emission spectrum, long fluorescence lifetime, strong anti-bleaching ability, and other optical properties. Moreover, since its fluorescence emission is located in the NIR-II region, has stronger penetrating ability for tissue. Ag2S quantum dot has strong absorption during the visible and NIR regions, it has good photothermal and photoacoustic response under certain wavelength excitation. 200 nm aqueous probe Ag2S@DSPE-PEG2000-FA (Ag2S@DP-FA) with good dispersibility and stability was prepared by coating hydrophobic Ag2S with the mixture of folic acid (FA) modified DSPE-PEG2000 (DP) and other polymers, it was found the probe had good fluorescent, photoacoustic and photothermal responses, and a low cell cytotoxicity at 50 μg/mL Ag concentration. Blood biochemical analysis, liver enzyme and tissue histopathological test showed that no significant influence was observed on blood and organs within 15 days after injection of the probe. In vivo and in vitro fluorescence and photoacoustic imaging of the probe further demonstrated that the Ag2S@DP-FA probe had good active targeting ability for tumor. In vivo and in vitro photothermal therapy experiments confirmed that the probe also had good ability of killing tumor by photothermal. Ag2S@DP-FA was a safe, integrated diagnosis and treatment probe with multi-mode imaging, photothermal therapy and active targeting ability, which had a great application prospect in the early diagnosis and treatment of tumor.

3 July 2014 in Nanotechnology
Verified
Journal Article
Closed access
JCJun Chen
Jun Chen
XYXiaoquan Yang
Xiaoquan Yang
YMYuan-Zheng Meng
Yuan-Zheng Meng
HHHuan-Huan Huang
Huan-Huan Huang
MQMeng-Yao Qin
Meng-Yao Qin
ZMZhi-Ya Ma
Zhi-Ya Ma
Probe bismuth sulfide modified with Pluronic F127 (Bi2S3-PF127), which has high biocompatibility and dispersibility, is synthesized using triblock copolymer Pluronic F127 to modify hydrophobic Bi2S3 nanoparticles that are prepared by a hot injection method. TEM results show that most of the probe has a length of about 14.85 ± 1.70 nm and a breadth of about 4.79 ± 0.63 nm. After injected into the tail vein of a mouse, the probe has obvious CT contrast enhancement capability from x-ray CT imaging results. Meanwhile, the probe's in vivo toxicity is also studied. It is found that hematoxylin and eosin stains of major organs have no change. A biochemical analysis (alanine aminotransferase and aspartate aminotransferase) prove the probe has no adverse effects. The results of a blood analysis (white blood cell count, red blood cell count, hemoglobin, and platelet count) are also normal. The biological distribution of Bi by ICP-AES shows that most of nanoparticles are cleaned out after injection 48 h, and the circulation half-life of the probe is 5.0 h, suggesting that Bi2S3-PF127 has a long circulation and indicating that the Bi2S3-PF127 probe has good biocompatibility and safety.