Hui Wang

Hui Wang

Auto-generated profile, based on publicly available information

Hui Wang

Huazhong University of Science and Technology, Britton Chance Center for Biomedical Photonics, Wuhan National Laboratory for Optoelectronics, 1037 Luoyu Road, Wuhan 430074, China

Research Focus & Metrics

Academic Career Length

20Years (2007-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2013 in Journal of Biomedical Optics
Verified
Journal Article
Open access
PDF file
YLYanyan Liu
Yanyan Liu
XYXiaoquan Yang
Xiaoquan Yang
HGHui Gong
Hui Gong
BJBowen Jiang
Bowen Jiang
HWHui Wang
Hui Wang
YDYong Deng
Yong Deng
Vasoactive drugs are normally utilized to elevate mean artery pressure and maintain adequate organ perfusion in clinical treatment. During the injection, morphological changes and the subsequent oxygen supply alteration in the brain, e.g., possible hypoxia, are prone to introduce serious damage and even dysfunction to the brain. Therefore, multiparameter monitoring of cerebral microvasculature is necessary during drug injection. An optical-resolution photoacoustic microscopy was used to assess the effects of norepinephrine on microvasculature in the brain cortex of mice. In our experiments, the diameter, total hemoglobin (HbT) and oxygen saturation (SO2) of single cerebral microvessels during tail vein injection of norepinephrine were analyzed. Following the injection, vasoconstriction was observed, and HbT and SO2 were decreased in turn. The vessel diameter and HbT recovered back to the base value without further injection, while the SO2 remained low throughout the observation period. Arterioles showed more acute constriction but a smaller decline in HbT during the injection compared with venules, while SO2 in arterioles increased slightly without further drug injection but not in venules. Our results suggested that photoacoustic microscopy may become a new method for early and comprehensive evaluation of the effect of drugs on microvasculature in brain.

2 October 2013 in Optics Express
Verified
Journal Article
Closed access
PDF file
HWHui Wang
Hui Wang
XYXiaoquan Yang
Xiaoquan Yang
YLYanyan Liu
Yanyan Liu
BJBowen Jiang
Bowen Jiang
QLQingming Luo
Qingming Luo
We developed a new reflection-mode optical-resolution photoacoustic microscopy (OR-PAM) based on the cooperation of a reflective objective and an ultrasonic transducer. The reflective objective is used to produce nearly diffraction-limited optical focusing, and the excited ultrasound waves are then directly detected by an ultrasonic transducer that was placed in the central cone of the objective. This new design avoids the coupling between optical focusing and ultrasound transmission in the reflection mode. Moreover, the proposed system is able to provide lateral resolution of 1.2 μm at 580 nm, penetration depth of 0.9 mm in biological tissues, and a work distance of 6.0 mm. We present in vivo imaging of the microvasculature in mouse ears and in vitro imaging of red blood cells (RBCs), which demonstrate the capability of the system to study microcirculation.

7 April 2008 in Journal of Physics D: Applied Physics
Verified
Journal Article
Closed access
PDF file
HWHui Wang
Hui Wang
DXDa Xing
Da Xing
LXLiangzhong Xiang
Liangzhong Xiang
A photoacoustic (PA) imaging system based on an ultrasonic Fresnel zone plate (FZP) transducer is developed for the purpose of imaging biological tissue. This FZP transducer has a two-zone negative zone plate piezoelectric material pattern, and an optical fibre is integrated with the transducer on the symmetric axis of the zone plates to deliver laser pulses to the sample. The focal characteristic of the FZP transducer is analysed by theoretical prediction and experimental measurement, and the measured results are in good agreement with the predicted results. The limited-field back-projection deconvolution algorithm combined with the coherence-factor weighting technique is used to reconstruct the optical absorption distribution. The experiments were performed with phantoms and the blood vessels of chicken embryo chorioallantoic membrane. The results demonstrate that PA imaging using the FZP transducer has the ability to image biological tissue and has potential application in monitoring neovascularization in tumour angiogenesis.

20 August 2021 in Clinical Oral Implants Research
Verified
Journal Article
Closed access
PDF file
YXYangbo Xu
Yangbo Xu
LZLiefen Zhang
Liefen Zhang
JXJiangang Xu
Jiangang Xu
JLJia Li
Jia Li
HWHui Wang
Hui Wang
FHFuming He
Fuming He

1 January 2012 in Journal of Biomedical Optics
Verified
Journal Article
Closed access
PDF file
HWHui Wang
Hui Wang
XYXiaoquan Yang
Xiaoquan Yang
ZWZhen Wang
Zhen Wang
ZDZilin Deng
Zilin Deng
HGHui Gong
Hui Gong
QLQingming Luo
Qingming Luo
Because cerebral hypoperfusion brings damage to the brain, prevention of cerebrovascular diseases correlative to hypoperfusion by studying animal models makes great sense. Since complicated cerebrovascular adaptive changes in hypoperfusion could not be revealed only by cerebral blood flow (CBF) velocity imaging, we performed multi-parameter imaging by combining laser speckle imaging and functional photoacoustic microscopy. The changes in CBF, hemoglobin oxygen saturation (SO2), and total hemoglobin concentration (HbT) in single blood vessels of ipsilateral cortex were observed during transient cerebral hypoperfusion by ligating the unilateral common carotid artery in rats. CBF, SO2, and HbT, respectively, decreased to 37±3%, 71±7.5%, and 92±1.3% of baseline in 6 s immediately after occlusion, and then recovered to 77±4.8%, 84±8%, and 96±2% of baseline in 60 s. These parameters presented the decrease with different degree and the following recovery over time after ligation, the recovery of SO2 lagged behind those of CBF and HbT, which had the similar response. The results demonstrated that complete monitoring of both cerebral hemodynamic response and oxygen metabolic changes occurred at the earliest period of cerebral hypoperfusion was possible by using the two image modalities with high temporal and spatial resolution.

1 January 2020 in Future Generation Computer Systems
Verified
Journal Article
Closed access
XSXiao-Li Sun
Xiao-Li Sun
HWHui Wang
Hui Wang
XLXin-Ke Li
Xin-Ke Li
GCGuo-Hong Cao
Guo-Hong Cao
YKYu Kuang
Yu Kuang
XZXiao-Chen Zhang
Xiao-Chen Zhang