Francesco Giannini

Dr. Francesco Giannini


Research Focus & Metrics

Academic Career Length

14Years (2013-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 January 2020 in JACC: Cardiovascular Interventions
Verified
Journal Article
Closed access
GGGuglielmo Gallone
Guglielmo Gallone
LBLuca Baldetti
Luca Baldetti
GTGeorgios Tzanis
Georgios Tzanis
MGMario Gramegna
Mario Gramegna
Azeem LatibAzeem Latib
Azeem Latib
FGFrancesco Giannini
Francesco Giannini

1 April 2018 in JACC: Cardiovascular Interventions
Verified
Journal Article
Closed access
FGFrancesco Giannini
Francesco Giannini
LBLuca Baldetti
Luca Baldetti
FPFrancesco Ponticelli
Francesco Ponticelli
NRNeil Ruparelia
Neil Ruparelia
SMSatoru Mitomo
Satoru Mitomo
ACAntonio Colombo
Antonio Colombo

1 October 2018 in International Journal of Cardiology
Verified
Journal Article
Closed access
FGFrancesco Giannini
Francesco Giannini
LBLuca Baldetti
Luca Baldetti
MKMaayan Konigstein
Maayan Konigstein
LRLiesbeth Rosseel
Liesbeth Rosseel
NRNeil Ruparelia
Neil Ruparelia
SVStefan Verheye
Stefan Verheye

28 September 2021 in Catheterization and Cardiovascular Interventions
Verified
Journal Article
Closed access
PDF file
BCBernardo Cortese
Bernardo Cortese
JHJose M. de la Torre Hernandez
Jose M. de la Torre Hernandez
MLMagdalena Lanocha
Magdalena Lanocha
AIAlfonso Ielasi
Alfonso Ielasi
FGFrancesco Giannini
Francesco Giannini
FBFrancesco Bianchini
Francesco Bianchini

25 February 2023 in Catheterization and Cardiovascular Interventions
Verified
Journal Article
Open access
AMAntonio Mangieri
Antonio Mangieri
RNRoberto Nerla
Roberto Nerla
FCFausto Castriota
Fausto Castriota
BRBernhard Reimers
Bernhard Reimers
DRDamiano Regazzoli
Damiano Regazzoli
ACAntonio Colombo
Antonio Colombo
Objectives: The objective of this study is to investigate the use of cutting balloon (CB) inflated at high pressure compared with noncompliant balloon (NCB) for the treatment of calcified coronary lesions.Background: No data are available regarding the safety and efficacy of CB inflated at high pressure in coronary artery calcifications.Methods: Patients with calcified lesions (more than 100° of calcium demonstrated at baseline intravascular ultrasound) were randomized. Primary endpoint of the study was the final minimal stent area (MSA) and stent symmetry in the calcific segment. Secondary endpoints included rate of device failure and the 1‐year rate of target lesion revascularization, target vessel revascularization, and major adverse cardiovascular events.Results: From September 2019 to June 2021, a total of 100 patients were included and randomized; 13 patients were excluded for major protocol deviations. Lesions were complex (type B2/C n = 61 [71.2%]) with a mean arch of calcium of 266 ± 84°, a calcium length of 12 ± 6.6 mm. CB was inflated at comparable atmospheres when compared with NCB (18.3 ± 5 vs. 19 ± 4.5, p = 0.46). In the per‐protocol population, the final MSA at the level of the calcium site was significantly higher in the CB group (8.1 ± 2 vs. 7.3 ± 2.1, p = 0.035) with a higher eccentricity index achieved in the CB group (0.84 ± 0.07 vs. 0.8 ± 0.08, p = 0.013). Three device failure occurred in the CB group. One‐year follow‐up outcomes were comparable.Conclusions: Treatment of calcified lesions with high‐pressure CB has a good safety profile and is associated with a larger MSA and higher eccentricity of the stent at the level of the calcium site compared with NCB.

1 July 2021 in Atherosclerosis
Verified
Journal Article
Closed access
ASAlessandra Scoccia
Alessandra Scoccia
GGGuglielmo Gallone
Guglielmo Gallone
ACAlberto Cereda
Alberto Cereda
APAnna Palmisano
Anna Palmisano
DVDavide Vignale
Davide Vignale
MTMarco Toselli
Marco Toselli