Martin Sebastian Zinkernagel

Prof. Dr. Martin Sebastian Zinkernagel


Research Focus & Metrics

Academic Career Length

22Years (2005-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
10 February 2012 in Arthritis & Rheumatism
Verified
Journal Article
Open access
PDF file
MRMerja Ruutu
Merja Ruutu
GTGethin Thomas
Gethin Thomas
RSRoland Steck
Roland Steck
MDMariapia A. Degli‐Esposti
Mariapia A. Degli‐Esposti
MZMartin Sebastian Zinkernagel
Martin Sebastian Zinkernagel
RTRanjeny Thomas
Ranjeny Thomas
Objective: The spondylarthritides (SpA), including ankylosing spondylitis (AS), psoriatic arthritis (PsA), reactive arthritis, and arthritis associated with inflammatory bowel disease, cause chronic inflammation of the large peripheral and axial joints, eyes, skin, ileum, and colon. Genetic studies reveal common candidate genes for AS, PsA, and Crohn's disease, including IL23R, IL12B, STAT3, and CARD9, all of which are associated with interleukin‐23 (IL‐23) signaling downstream of the dectin 1 β‐glucan receptor. In autoimmune‐prone SKG mice with mutated ZAP‐70, which attenuates T cell receptor signaling and increases the autoreactivity of T cells in the peripheral repertoire, IL‐17–dependent inflammatory arthritis developed after dectin 1–mediated fungal infection. This study was undertaken to determine whether SKG mice injected with 1,3‐β‐glucan (curdlan) develop evidence of SpA, and the relationship of innate and adaptive autoimmunity to this process.Methods: SKG mice and control BALB/c mice were injected once with curdlan or mannan. Arthritis was scored weekly, and organs were assessed for pathologic features. Anti–IL‐23 monoclonal antibodies were injected into curdlan‐treated SKG mice. CD4+ T cells were transferred from curdlan‐treated mice to SCID mice, and sera were analyzed for autoantibodies.Results: After systemic injection of curdlan, SKG mice developed enthesitis, wrist, ankle, and sacroiliac joint arthritis, dactylitis, plantar fasciitis, vertebral inflammation, ileitis resembling Crohn's disease, and unilateral uveitis. Mannan triggered spondylitis and arthritis. Arthritis and spondylitis were T cell– and IL‐23–dependent and were transferable to SCID recipients with CD4+ T cells. SpA was associated with collagen‐ and proteoglycan‐specific autoantibodies.Conclusion: Our findings indicate that the SKG ZAP‐70W163C mutation predisposes BALB/c mice to SpA, resulting from innate and adaptive autoimmunity, after systemic β‐glucan or mannan exposure.

17 January 2017 in Scientific Reports
Verified
Journal Article
Open access
MZMartin Sebastian Zinkernagel
Martin Sebastian Zinkernagel
DZDenise C. Zysset-Burri
Denise C. Zysset-Burri
IKIrene Keller
Irene Keller
LBLieselotte E. Berger
Lieselotte E. Berger
ALAlexander B. Leichtle
Alexander B. Leichtle
SWSebastian Wolf
Sebastian Wolf
Age-related macular degeneration (AMD) is the most frequent cause of blindness in the elderly. There is evidence that nutrition, inflammation and genetic risk factors play an important role in the development of AMD. Recent studies suggest that the composition of the intestinal microbiome is associated with metabolic diseases through modulation of inflammation and host metabolism. To investigate whether compositional and functional alterations of the intestinal microbiome are associated with AMD, we sequenced the gut metagenomes of patients with AMD and controls. The genera Anaerotruncus and Oscillibacter as well as Ruminococcus torques and Eubacterium ventriosum were relatively enriched in patients with AMD, whereas Bacteroides eggerthii was enriched in controls. Patient’s intestinal microbiomes were enriched in genes of the L-alanine fermentation, glutamate degradation and arginine biosynthesis pathways and decreased in genes of the fatty acid elongation pathway. These findings suggest that modifications in the intestinal microbiome are associated with AMD, inferring that this common sight threatening disease may be targeted by microbiome-altering interventions.

10 May 2017 in PLOS ONE
Verified
Journal Article
Open access
PDF file
MMMarion R Munk
Marion R Munk
HGHelena Giannakaki-Zimmermann
Helena Giannakaki-Zimmermann
LBLieselotte Berger
Lieselotte Berger
WHWolfgang Huf
Wolfgang Huf
AEAndreas Ebneter
Andreas Ebneter
MZMartin Sebastian Zinkernagel
Martin Sebastian Zinkernagel
To compare the quality of four OCT-angiography(OCT-A) modules. The retina of nineteen healthy volunteers were scanned with four OCT-devices (Topcon DRI-OCT Triton Swept-source OCT, Optovue RTVue-XR, a prototype Spectralis OCT2, Heidelberg-Engineering and Zeiss Cirrus 5000-HD-OCT). The device-software generated en-face OCT-A images of the superficial (SCP) and deep capillary plexuses (DCP) were evaluated and scored by 3 independent retinal imaging experts. The SCP vessel density was assessed using Angiotool-software. After the inter-grader reliability assessment, a consensus grading was performed and the modules were ranked based on their scoring. There was no significant difference in the vessel density among the modules (Zeiss 48.7±4%, Optovue 47.9±3%, Topcon 48.3±2%, Heidelberg 46.5±4%, p = 0.2). The numbers of discernible vessel-bifurcations differed significantly on each module (Zeiss 2±0.9 bifurcations, Optovue 2.5±1.2, Topcon 1.3±0.7 and Heidelberg 0.5±0.6, p≤0.001). The ranking of each module differed depending on the evaluated parameter. In the overall ranking, the Zeiss module was superior and in 90% better than the median (Bonferroni corrected p-value = 0.04). Optovue was better than the median in 60%, Topcon in 40% and Heidelberg module in 10%, however these differences were not statistically significant. Each of the four evaluated OCT-A modules had particular strengths, which differentiated it from their competitors.

1 September 2017 in Progress in Retinal and Eye Research
Verified
Journal Article
Open access
CDChantal Dysli
Chantal Dysli
SWSebastian Wolf
Sebastian Wolf
MBMikhail Y. Berezin
Mikhail Y. Berezin
LSLydia Sauer
Lydia Sauer
MHMartin Hammer
Martin Hammer
MZMartin Sebastian Zinkernagel
Martin Sebastian Zinkernagel
Imaging techniques based on retinal autofluorescence have found broad applications in ophthalmology because they are extremely sensitive and noninvasive. Conventional fundus autofluorescence imaging measures fluorescence intensity of endogenous retinal fluorophores. It mainly derives its signal from lipofuscin at the level of the retinal pigment epithelium. Fundus autofluorescence, however, can not only be characterized by the spatial distribution of the fluorescence intensity or emission spectrum, but also by a characteristic fluorescence lifetime function. The fluorescence lifetime is the average amount of time a fluorophore remains in the excited state following excitation. Fluorescence lifetime imaging ophthalmoscopy (FLIO) is an emerging imaging modality for in vivo measurement of lifetimes of endogenous retinal fluorophores. Recent reports in this field have contributed to our understanding of the pathophysiology of various macular and retinal diseases. Within this review, the basic concept of fluorescence lifetime imaging is provided. It includes technical background information and correlation with in vitro measurements of individual retinal metabolites. In a second part, clinical applications of fluorescence lifetime imaging and fluorescence lifetime features of selected retinal diseases such as Stargardt disease, age-related macular degeneration, choroideremia, central serous chorioretinopathy, macular holes, diabetic retinopathy, and retinal artery occlusion are discussed. Potential areas of use for fluorescence lifetime imaging ophthalmoscopy will be outlined at the end of this review.

1 January 2014 in Ophthalmology
Verified
Journal Article
Closed access
MAMathias Abegg
Mathias Abegg
MDMuriel Dysli
Muriel Dysli
SWSebastian Wolf
Sebastian Wolf
JKJens Kowal
Jens Kowal
PDPascal Dufour
Pascal Dufour
MZMartin Sebastian Zinkernagel
Martin Sebastian Zinkernagel

1 June 2009 in The American Journal of Pathology
Verified
Journal Article
Closed access
SJSandrine Joly
Sandrine Joly
MFMike Francke
Mike Francke
EUElke Ulbricht
Elke Ulbricht
SBSusanne Beck
Susanne Beck
MSMatthias Seeliger
Matthias Seeliger
CRCharlotte E. Remé
Charlotte E. Remé