Mats Scheurer

Dr. Mats Scheurer


Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
18 September 2023 in Journal of Clinical Medicine
Verified
Journal Article
Open access
PDF file
RKReinald Kuehle
Reinald Kuehle
MSMats Scheurer
Mats Scheurer
FBFrederic Bouffleur
Frederic Bouffleur
JFJennifer Fuchs
Jennifer Fuchs
MEMichael Engel
Michael Engel
CFChristian Freudlsperger
Christian Freudlsperger
(1) Background: In orthognathic surgery, segmental Le Fort I osteotomies are a valuable method to correct maxillary deformities or transversal discrepancies. However, these procedures are technically challenging, and osteosynthesis can be prone to error. (2) Methods: In this retrospective, monocentric cohort study, patients were enrolled who underwent a virtually planned segmental maxillary osteotomy during their combined treatment. Positioning and osteosynthesis were achieved by either a 3D-printed splint and conventional miniplates or patient-specific implants (PSI). The preoperative CT data, virtual planning data, and postoperative CBCT data were segmented. The deviation of all the segments from the desired virtually planned position was measured using the analysis function of IPS CaseDesigner. (3) Results: 28 Patients in the PSI Group and 22 in the conventional groups were included. The PSI group showed significantly lower deviation from the planned position anteroposteriorly (−0.63 ± 1.62 mm vs. −1.3 ± 2.54 mm) and craniocaudally (−1.39 ± 1.59 mm vs. −2.7 ± 3.1 mm). For rotational deviations, the pitch (0.64 ± 2.59° vs. 2.91 ± 4.08°), as well as the inward rotation of the lateral segments, was positively influenced by PSI. (4). Conclusions: The presented data show that patient-specific osteosynthesis significantly reduces deviations from the preoperative plan in virtually planned cases. Transversal expansions and vertical positioning can be addressed better.

Verified
Journal Article
Open access
PDF file
LHLutz D. Hodecker
Lutz D. Hodecker
MSMats Scheurer
Mats Scheurer
SSSven Scharf
Sven Scharf
CRChristoph Roser
Christoph Roser
AFAhmed M. Fouda
Ahmed M. Fouda
CSCarolien A. J. Scheurer
Carolien A. J. Scheurer
(1) Background: Novel high-performance polymers for medical 3D printing enable in-office manufacturing of fully customized brackets. Previous studies have investigated clinically relevant parameters such as manufacturing precision, torque transmission, and fracture stability. The aim of this study is to evaluate different design options of the bracket base concerning the adhesive bond between the bracket and tooth, measured as the shear bond strength (SBS) and maximum force (Fmax) according to DIN 13990. (2) Methods: Three different designs for printed bracket bases were compared with a conventional metal bracket (C). The following configurations were chosen for the base design: Matching of the base to the anatomy of the tooth surface, size of the cross-sectional area corresponding to the control group (C), and a micro- (A) and macro- (B) retentive design of the base surface. In addition, a group with a micro-retentive base (D) matched to the tooth surface and an increased size was studied. The groups were analyzed for SBS, Fmax, and adhesive remnant index (ARI). The Kruskal–Wallis test with a post hoc test (Dunn–Bonferroni) and Mann–Whitney U test were used for statistical analysis (significance level: p < 0.05). (3) Results: The values for SBS and Fmax were highest in C (SBS: 12.0 ± 3.8 MPa; Fmax: 115.7 ± 36.6 N). For the printed brackets, there were significant differences between A and B (A: SBS 8.8 ± 2.3 MPa, Fmax 84.7 ± 21.8 N; B: SBS 12.0 ± 2.1 MPa, Fmax 106.5 ± 20.7 N). Fmax was significantly different for A and D (D: Fmax 118.5 ± 22.8 N). The ARI score was highest for A and lowest for C. (4) Conclusions: This study shows that conventional brackets form a more stable bond with the tooth than the 3D-printed brackets. However, for successful clinical use, the shear bond strength of the printed brackets can be increased with a macro-retentive design and/or enlargement of the base.

14 August 2023 in Preprints.org
Verified
Preprint
Open access
PDF file
RKReinald Kuehle
Reinald Kuehle
MSMats Scheurer
Mats Scheurer
FBFrederic Bouffleur
Frederic Bouffleur
JFJennifer Fuchs
Jennifer Fuchs
MEMichael Engel
Michael Engel
CFChristian Freudlsperger
Christian Freudlsperger
(1) Background: In orthognathic surgery, segmental Le Fort I osteotomies are a valuable method to correct maxillary deformities or transversal discrepancies. However, these procedures are technically challenging, and osteosynthesis can be prone to error. (2) Methods: In this retrospective, monocentric cohort study, patients were enrolled who underwent a virtually planned segmental maxillary osteotomy during their combined treatment. Positioning and osteosynthesis were achieved by either a 3D-printed splint and conventional mini plates or Patient-Specific Implants (PSI). The preoperative CT data, virtual planning data, and postoperative CBCT data were segmented. The deviation of all segments from the desired virtually planned position was measured using the analysis function of the IPS Case Designer. (3) Results: 28 Patients in the PSI Group and 22 in the conventional groups could be included. The PSI group showed significantly lower deviation from the planned position anteroposteriorly (-0.63±1.62mm vs. -1.3±2.54mm) and craniocaudally (-1.39±1.59mm vs. -2.7±3.1mm). For rotational deviations, the Pitch (0.64±2.59° vs. 2.91±4.08°) as well as the inward rotation of the lateral segments was positively influenced by PSI. (4). Conclusions: The presented data show that patient-specific osteosynthesis significantly reduces deviations from the preoperative plan in virtually planned cases. Especially transversal expansions and vertical positioning can be addressed better.

21 August 2026 in Bioengineering
Verified
Journal Article
Open access
PDF file
CSCarolien A. J. Scheurer
Carolien A. J. Scheurer
LDLuise H. Dommack
Luise H. Dommack
DRDelia B. Rieken
Delia B. Rieken
CBChristoph P Bourauel
Christoph P Bourauel
LKLudger Keilig
Ludger Keilig
JMJuliana Marie-Kristine Mielke
Juliana Marie-Kristine Mielke
Skeletal-anchored mesial sliders are increasingly used for molar mesialization, yet their mechanical behavior has not been compared under standardized conditions. This in vitro pilot study evaluated four slider designs (BENEfit® Beneslider [BB], TADMAN Beneslider [TB], IZE Slider [IO; OrthoLIZE GmbH], Slider on Minipin [SO; OrthoLIZE GmbH]), each combined with elastic chains (-C) or NiTi springs (-S), to characterize force loss, mesial movement, and associated mechanical side effects using an experimental biomechanical measurement system. Using repeated measurements on one specimen with 1 N of applied force, three-dimensional tooth movements were recorded across 200 simulation steps per run. The sliders showed design-dependent mechanical patterns: IO sliders produced the smallest sagittal movements (IO-C: −0.84 mm [0.05], IO-S: −0.79 mm [0.02]) and the highest force loss (IO-C: 88.1% [2.1], IO-S: 89.8% [0.3]), whereas BB-S and TB-S generated larger mesialization distances (BB-S: −3.55 mm [0.53], TB-S: −3.46 mm [0.08]) with lower force loss (BB-S: 42.8% [9.2], TB-S: 21.1% [2.9]). Translational deviations remained small, while rotational effects were more pronounced. These findings represent mechanical tendencies of the tested configurations under idealized conditions and do not account for biological variability, periodontal compliance, or patient-specific factors. As such, the results cannot be generalized to clinical performance but provide preliminary reference data. Expanded investigations using multiple specimens, biological modeling, or finite element analysis will be necessary to determine how these mechanical patterns translate into clinical tooth movement.