Alejandro Roldan-Alzate

Dr. Alejandro Roldan-Alzate


Research Focus & Metrics

Academic Career Length

18Years (2009-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
12 November 2012 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
ARAlejandro Roldan-Alzate
Alejandro Roldan-Alzate
AFAlex Frydrychowicz
Alex Frydrychowicz
ENEric Niespodzany
Eric Niespodzany
BLBen R. Landgraf
Ben R. Landgraf
KJKevin M. Johnson
Kevin M. Johnson
SRScott B. Reeder
Scott B. Reeder
Purpose: To implement and validate in vivo radial 4D flow MRI for quantification of blood flow in the hepatic arterial, portal venous, and splanchnic vasculature of healthy volunteers and patients with portal hypertension.Materials and Methods: Seventeen patients with portal hypertension and seven subjects with no liver disease were included in this Health Insurance Portability and Accountability Act (HIPAA)‐compliant and Institutional Review Board (IRB)‐approved study. Exams were conducted at 3T using a 32‐channel body coil with large volumetric coverage and 1.4 mm isotropic true spatial resolution. Using postprocessing software, cut‐planes orthogonal to vessels were used to quantify flow (L/min) in the hepatic and splanchnic vasculature.Results: Flow quantification was successful in all cases. Portal vein and supraceliac aorta flow demonstrated high variability among patients. Measurements were validated indirectly using internal consistency at three different locations within the portal vein (error = 4.2 ± 3.9%) and conservation of mass at the portal confluence (error = 5.9 ± 2.5%) and portal bifurcation (error = 5.8 ± 3.1%).Conclusion: This work demonstrates the feasibility of radial 4D flow MRI to quantify flow in the hepatic and splanchnic vasculature. Flow results agreed well with data reported in the literature, and conservation of mass provided indirect validation of flow quantification. Flow in patients with portal hypertensions demonstrated high variability, with patterns and magnitude consistent with the hyperdynamic state that commonly occurs in portal hypertension. J. Magn. Reson. Imaging 2013;37:1100–1108.

16 March 2015 in Journal of Magnetic Resonance Imaging
Verified
Journal Article
Open access
PDF file
ARAlejandro Roldan-Alzate
Alejandro Roldan-Alzate
AFAlex Frydrychowicz
Alex Frydrychowicz
ASAdnan Said
Adnan Said
KJKevin M. Johnson
Kevin M. Johnson
Christopher FrancoisChristopher Francois
Christopher Francois
SRScott B. Reeder
Scott B. Reeder
Purpose: Portal and mesenteric hemodynamics is greatly altered in portal hypertension patients. This study utilizes 4D flow magnetic resonance imaging (MRI) to visualize and quantify changes in abdominal hemodynamics in patients with portal hypertension undergoing meal challenge.Materials and Methods: Twelve portal hypertension patients and six healthy subjects participated in the study. Baseline MRI was acquired after 5 hours of fasting. Postmeal MRI was obtained 20 minutes after subjects ingested EnSure Plus (574 mL). Imaging was performed at 3T using 4D flow MRI with an undersampled radial acquisition. Flow measurements were performed blinded to subject status (fasting/meal). Flow values for each vessel were compared before and after the meal challenge using paired Student's t‐tests (P < 0.05).Results: After meal challenge, significant increases in blood flow were observed in supraceliac aorta, portal vein, superior mesenteric vein, and artery in both groups (P < 0.05). In patients, hepatic artery (P = 0.001) and splenic vein (P = 0.045) flow decreased while azygos vein flow (P = 0.002) increased.Conclusion: Portal venous flow regulation to adjust the increasing mesenteric venous flow after a meal challenge may be impaired in patients with cirrhosis. The ability to comprehensively quantify the hemodynamic response of the abdominal vasculature to a meal challenge using 4D flow MRI reveals the potential of this technique to noninvasively characterize portal hypertension hemodynamics. J. Magn. Reson. Imaging 2015;42:1009–1017.

10 June 2020 in Annals of Biomedical Engineering
Verified
Journal Article
Closed access
PDF file
RMRafael Medero
Rafael Medero
KRKatrina Ruedinger
Katrina Ruedinger
DRDavid Rutkowski
David Rutkowski
KJKevin Johnson
Kevin Johnson
ARAlejandro Roldan-Alzate
Alejandro Roldan-Alzate

1 July 2016 in American Journal of Roentgenology
Verified
Journal Article
Closed access
ARAlejandro Roldan-Alzate
Alejandro Roldan-Alzate
Christopher FrancoisChristopher Francois
Christopher Francois
OWOliver Wieben
Oliver Wieben
SRScott B. Reeder
Scott B. Reeder
OBJECTIVE. Comprehensive assessment of abdominal hemodynamics is crucial for many clinical diagnoses but is challenged by a tremendous complexity of anatomy, normal physiology, and a wide variety of pathologic abnormalities. This article introduces 4D flow MRI as a powerful technique for noninvasive assessment of the hemodynamics of abdominal vascular territories. CONCLUSION. Four-dimensional flow MRI provides clinicians with a more extensive and straightforward approach to evaluate disorders that affect blood flow in the abdomen. This review presents a series of clinical cases to illustrate the utility of 4D flow MRI in the comprehensive assessment of the abdominal circulation.

1 May 2015 in Journal of Biomechanics
Verified
Journal Article
Open access
ARAlejandro Roldan-Alzate
Alejandro Roldan-Alzate
SGSylvana García-Rodríguez
Sylvana García-Rodríguez
PAPetros V. Anagnostopoulos
Petros V. Anagnostopoulos
SSShardha Srinivasan
Shardha Srinivasan
OWOliver Wieben
Oliver Wieben
Christopher FrancoisChristopher Francois
Christopher Francois
Altered total cavopulmonary connection (TCPC) hemodynamics can cause long-term complications. Patient-specific anatomy hinders generalized solutions. 4D Flow MRI allows in vivo assessment, but not predictions under varying conditions and surgical approaches. Computational fluid dynamics (CFD) improves understanding and explores varying physiological conditions. This study investigated a combination of 4D Flow MRI and CFD to assess TCPC hemodynamics, accompanied with in vitro measurements as CFD validation. 4D Flow MRI was performed in extracardiac and atriopulmonary TCPC subjects. Data was processed for visualization and quantification of velocity and flow. Three-dimensional (3D) geometries were generated from angiography scans and used for CFD and a physical model construction through additive manufacturing. These models were connected to a perfusion system, circulating water through the vena cavae and exiting through the pulmonary arteries at two flow rates. Models underwent 4D Flow MRI and image processing. CFD simulated the in vitro system, applying two different inlet conditions from in vitro 4D Flow MRI measurements; no-slip was implemented at rigid walls. Velocity and flow were obtained and analyzed. The three approaches showed similar velocities, increasing proportionally with high inflow. Atriopulmonary TCPC presented higher vorticity compared to extracardiac at both inflow rates. Increased inflow balanced flow distribution in both TCPC cases. Atriopulmonary IVC flow participated in atrium recirculation, contributing to RPA outflow; at baseline, IVC flow preferentially traveled through the LPA. The combination of patient-specific in vitro and CFD allows hemodynamic parameter control, impossible in vivo. Physical models serve as CFD verification and fine-tuning tools.

18 August 2016 in JCI Insight
Verified
Journal Article
Open access
PDF file
IKIldiko Kasza
Ildiko Kasza
DHDiego Hernando
Diego Hernando
ARAlejandro Roldan-Alzate
Alejandro Roldan-Alzate
CACaroline M. Alexander
Caroline M. Alexander
SRScott B. Reeder
Scott B. Reeder
Dermal white adipose tissue (dWAT) was recently recognized for its potential to modify whole body metabolism. Here, we show that dWAT can be quantified using a high-resolution, fat-specific magnetic resonance imaging (MRI) technique. Noninvasive MRI has been used to describe adipocyte depots for many years; the MRI technique we describe uses an advanced fat-specific method to measure the thickness of dWAT, together with the total volume of WAT and the relative activation/fat depletion of brown adipose tissues (BAT). Since skin-embedded adipocytes may provide natural insulation, they provide an important counterpoint to the activation of thermogenic brown and beige adipose tissues, whereby these distinct depots are functionally interrelated and require simultaneous assay. This method was validated using characterized mouse cohorts of a lipodystrophic, dWAT-deficient strain (syndecan-1 KO) and 2 obese models (diet-induced obese mice and genetically obese animals, ob/ob ). Using a preliminary cohort of normal human subjects, we found the thickness of skin-associated fat varied 8-fold, from 0.13–1.10 cm; on average, this depot is calculated to weigh 8.8 kg.