In Alzheimer's continuum (a comprehensive of preclinical Alzheimer's disease [AD], mild cognitive impairment [MCI] due to AD, and AD dementia), cognitive dysfunctions are often related to cortical atrophy in specific brain regions. The purpose of this study was to investigate the association between anatomical pattern of cortical atrophy and specific neuropsychological deficits. A total of 249 participants with Alzheimer's continuum (125 AD dementia, 103 MCI due to AD, and 21 preclinical AD) who were confirmed to be positive for amyloid deposits were collected from the memory disorder clinic in the department of neurology at Samsung Medical Center in Korea between September 2013 and March 2018. To analyze neuropsychological test-specific neural correlates representing the relationship between cortical atrophy measured by cortical thickness and performance in specific neuropsychological tests, a linear regression analysis was performed. Two neural correlates acquired by 2 different standardized scores in neuropsychological tests were also compared. Cortical atrophy in several specific brain regions was associated with most neuropsychological deficits, including digit span backward, naming, drawing-copying, verbal and visual recall, semantic fluency, phonemic fluency, and response inhibition. There were a few differences between 2 neural correlates obtained by different z-scores. The poor performance of most neuropsychological tests is closely related to cortical thinning in specific brain areas in Alzheimer's continuum. Therefore, the brain atrophy pattern in patients with Alzheimer's continuum can be predict by an accurate analysis of neuropsychological tests in clinical practice.
1 January 2020 in Journal of Korean Medical Science
Cerebrospinal fluid (CSF) flow is crucial for brain homeostasis and its dysfunction is highly associated with neurodegenerative diseases. Restoring CSF circulation is proposed as a key strategy for the treatment of the diseases. Among the methods to improve CSF circulation, focused ultrasound (FUS) stimulation has emerged as a promising non-invasive brain stimulation technique, with effectiveness evidenced by ex vivo studies. However, due to technical disturbances in in vivo imaging combined with FUS, direct evidence of real-time in vivo CSF flow enhancement by FUS remains elusive. To investigate whether FUS administered through the skull base can enhance CSF influx in living animals with various real-time imaging techniques. We demonstrate a novel method of applying FUS through the skull base, facilitating cortical CSF influx, evidenced by diverse in vivo imaging techniques. Acoustic simulation confirmed effective sonication of our approach through the skull base. After injecting fluorescent CSF tracers into cisterna magna, FUS was administered at the midline of the jaw through the skull base for 30 minutes, during which imaging was performed concurrently. Enhanced CSF influx was observed in macroscopic imaging, demonstrated by the influx area and intensity of the fluorescent dyes after FUS. In two-photon imaging, increased fluorescence was observed in the perivascular space (PVS) after stimulation. Moreover, particle tracking of microspheres showed more microspheres entering the imaging field, with increased mean speed after FUS. Our findings provide direct real-time in vivo imaging evidence that FUS promotes CSF influx and flow in the PVS.
Purpose: The purpose of this study was to evaluate if transcutaneous application of low-intensity ultrasound can locally enhance the effects of finasteride on hair growth in a murine model of androgenic alopecia (AA).Methods: AA mice (injected twice per week with testosterone enanthate, n=11), under daily oral administration of finasteride, received 1-MHz ultrasound for 1 hour at the unilateral thigh area five times per week for 5 weeks. Non-thermal and non-cavitational ultrasound was delivered in a pulsed manner (55-ms pulse duration with a repetition frequency of 4 Hz). Skin temperature was measured during sonication, and the measurements were validated with numerical simulations of sonication-induced tissue temperature changes. Hair growth was assessed both photographically and histologically.Results: We found more hair growth on the sonicated thigh area than on the unsonicated thigh, beginning from week 3 through the end of the experiment. Histological analyses showed that the number of hair follicles doubled in the skin sections that received sonication compared to the unsonicated zone, with thicker follicular diameter and skin. An over five-fold increase was also observed in the anagen/telogen ratio in the sonicated area, suggesting an enhanced anagen phase. Skin temperature was unaltered by the administered sonication.Conclusion: The findings of the present study suggest that pulsed application of ultrasound promotes hair growth, potentially by disrupting the binding of albumin to finasteride. This may suggest further applications to enhance the pharmacological effects of other relevant drugs exhibiting high plasma protein binding.