Resonant photon modes of a 5-mm-diameter yttrium iron garnet (YIG) sphere loaded in a cylindrical cavity in the 10–30-GHz frequency range are characterized as a function of applied dc magnetic field at millikelvin temperatures. The photon modes are confined mainly to the sphere and exhibited large mode filling factors in comparison to previous experiments, allowing ultrastrong coupling with the magnon spin-wave resonances. The largest observed coupling between photons and magnons is GHz for a 15.5-GHz mode, corresponding to a cooperativity of . Complex modifications, beyond a simple multioscillator model, of the photon mode frequencies were observed between 0 and 0.1 T. Between 0.4 and 1 T, degenerate resonant photon modes were observed to interact with magnon spin-wave resonances with different coupling strengths, indicating time-reversal symmetry breaking due to the gyrotropic permeability of YIG. Bare dielectric resonator mode frequencies were determined by detuning magnon modes to significantly higher frequencies with strong magnetic fields. By comparing measured mode frequencies at 7 T with finite element modeling, a bare dielectric permittivity of of the YIG crystal has been determined at about 20 mK.
Recent progress in observing and manipulating mechanical oscillators at quantum regime provides new opportunities of studying fundamental physics, for example to search for low energy signatures of quantum gravity. For example, it was recently proposed that such devices can be used to test quantum gravity effects, by detecting the change in the commutation relation that could result from quantum gravity corrections. We show that such a correction results in a dependence of a resonant frequency of a mechanical oscillator on its amplitude, which is known as the amplitude-frequency effect. By implementing this new method we measure the amplitude-frequency effect for a 0.3 kg ultra-high-Q sapphire split-bar mechanical resonator and for an quartz bulk acoustic wave resonator. Our experiments with a sapphire resonator have established the upper limit on a quantum gravity correction constant of to not exceed , which is a factor of 6 better than previously measured. The reasonable estimates of from experiments with quartz resonators yields . The datasets of 1936 measurements of a physical pendulum period by Atkinson [E. C. Atkinson, Proc. Phys. Soc. London 48, 606 (1936).] could potentially lead to significantly stronger limitations on . Yet, due to the lack of proper pendulum frequency stability measurement in these experiments the exact upper bound on cannot be reliably established. Moreover, pendulum based systems only allow one to test a specific form of the modified commutator that depends on the mean value of momentum. The electromechanical oscillators to the contrary enable testing of any form of generalized uncertainty principle directly due to a much higher stability and a higher degree of control.
Several experimental implementations of cavity-magnon systems are presented. First an Yttrium Iron Garnet (YIG) block is placed inside a re-entrant cavity where the resulting hybrid mode is measured to be in the ultra strong coupling (USC) regime. When fully hybridised the ratio between the coupling rate and uncoupled mode frequencies is determined to beg/ω = 0.46. Next a thin YIG cylinder is placed inside a loop gap cavity. The bright mode of this cavity couples to the YIG sample and is similarly measured to be in the USC regime with ratio of coupling rate to uncoupled mode frequencies asg/ω = 0.34. A larger spin density medium such as lithium ferrite (LiFe) is expected to improve couplings by a factor of 1.46 in both systems as coupling strength is shown to be proportional to the square root of spin density and magnetic moment. Such strongly coupled systems are potentially useful for cavity QED, hybrid quantum systems and precision dark matter detection experiments. The YIG disc in the loop gap cavity, is, in particular, shown to be a strong candidate for dark matter detection. Finally, a LiFe sphere inside a two post re-entrant cavity is considered. In past work it was shown that the magnon mode in the sample has a turnover point in frequency (Goryachevet al2018Phys. Rev.B97155129). Additionally, it was predicted that if the system was engineered such that it fully hybridised at this turnover point the cavity-magnon polariton transition frequency would become insensitive to both first and second order magnetic bias field fluctuations, a result useful for precision frequency applications. This work implements such a system by engineering the cavity mode frequency to near this turnover point, with suppression in sensitivity to second order bias magnetic field fluctuations shown.
1 December 2013 in Review of Scientific Instruments
Cylindrical re-entrant cavities are unique three-dimensional structures that resonate with their electric and magnetic fields in separate parts of the cavity. To further understand these devices, we undertake rigorous analysis of the properties of the resonance using “in-house” developed Finite Element Method (FEM) software capable of dealing with small gap structures of extreme aspect ratio. Comparisons between the FEM method and experiments are consistent and we illustrate where predictions using established lumped element models work well and where they are limited. With the aid of the modeling we design a highly tunable cavity that can be tuned from 2 GHz to 22 GHz just by inserting a post into a fixed dimensioned cylindrical cavity. We show this is possible, as the mode structure transforms from a re-entrant mode during the tuning process to a standard cylindrical transverse magnetic mode.