Michael Tobar

Michael Tobar

orcid

Research Focus & Metrics

Academic Career Length

36Years (1991-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
5 November 2014 in Physical Review Applied
Verified
Journal Article
Closed access
PDF file
MGMaxim Goryachev
Maxim Goryachev
WFWarrick G. Farr
Warrick G. Farr
DCDaniel L. Creedon
Daniel L. Creedon
YFYaohui Fan
Yaohui Fan
MKMikhail Kostylev
Mikhail Kostylev
MTMichael Tobar
Michael Tobar
Using a submillimeter-sized YIG (yttrium-iron-garnet) sphere mounted in a magnetic-field-focusing cavity, we demonstrate an ultrahigh cooperativity of 105 between magnon and photon modes at millikelvin temperatures and microwave frequencies. The cavity is designed to act as a magnetic dipole by using a novel multiple-post approach, effectively focusing the cavity magnetic field within the YIG crystal with a filling factor of 3%. Coupling strength (normal-mode splitting) of 2 GHz (equivalent to 76 cavity linewidths or 0.3 Hz per spin) is achieved for a bright cavity mode that constitutes about 10% of the photon energy and shows that ultrastrong coupling is possible in spin systems at microwave frequencies. With straightforward optimizations we demonstrate that this system has the potential to reach cooperativities of 107, corresponding to a normal-mode splitting of 5.2 GHz and a coupling per spin approaching 1 Hz. We also observe a three-mode strong-coupling regime between a dark cavity mode and a magnon-mode doublet pair, where the photon-magnon and magnon-magnon couplings (normal-mode splittings) are 143 and 12.5 MHz, respectively, with a HWHM bandwidth of about 0.5 MHz.

1 December 2017 in Physics of the Dark Universe
Verified
Journal Article
Closed access
BMBen T. McAllister
Ben T. McAllister
GFGraeme Flower
Graeme Flower
EIEugene N. Ivanov
Eugene N. Ivanov
MGMaxim Goryachev
Maxim Goryachev
JBJeremy Bourhill
Jeremy Bourhill
MTMichael Tobar
Michael Tobar

3 April 2012 in IEEE Transactions on Ultrasonics, Ferroelectrics, and Frequency Control
Verified
Journal Article
Closed access
JGJocelyne Guena
Jocelyne Guena
MAMichel Abgrall
Michel Abgrall
DRDaniele Rovera
Daniele Rovera
PLPhilippe Laurent
Philippe Laurent
BCBaptiste Chupin
Baptiste Chupin
SBSebastien Bize
Sebastien Bize
We give an overview of the work done with the Laboratoire National de Metrologie et d'Essais-Systemes de Reference Temps-Espace (LNE-SYRTE) fountain ensemble during the last five years. After a description of the clock ensemble, comprising three fountains, FO1, FO2, and FOM, and the newest developments, we review recent studies of several systematic frequency shifts. This includes the distributed cavity phase shift, which we evaluate for the FO1 and FOM fountains, applying the techniques of our recent work on FO2. We also report calculations of the microwave lensing frequency shift for the three fountains, review the status of the blackbody radiation shift, and summarize recent experimental work to control microwave leakage and spurious phase perturbations. We give current accuracy budgets. We also describe several applications in time and frequency metrology: fountain comparisons, calibrations of the international atomic time, secondary representation of the SI second based on the 87Rb hyperfine frequency, absolute measurements of optical frequencies, tests of the T2L2 satellite laser link, and review fundamental physics applications of the LNE-SYRTE fountain ensemble. Finally, we give a summary of the tests of the PHARAO cold atom space clock performed using the FOM transportable fountain.

1 January 1999 in Measurement Science and Technology
Verified
Journal Article
Closed access
PDF file
JKJerzy Krupka
Jerzy Krupka
KDKrzysztof Derzakowski
Krzysztof Derzakowski
MTMichael Tobar
Michael Tobar
JHJohn Hartnett
John Hartnett
RGRichard G Geyer
Richard G Geyer

25 April 2016 in Physical Review B
Verified
Journal Article
Open access
PDF file
JBJeremy Bourhill
Jeremy Bourhill
NKN. Kostylev
N. Kostylev
MGMaxim Goryachev
Maxim Goryachev
DCD. L. Creedon
D. L. Creedon
MTMichael Tobar
Michael Tobar
Resonant photon modes of a 5-mm-diameter yttrium iron garnet (YIG) sphere loaded in a cylindrical cavity in the 10–30-GHz frequency range are characterized as a function of applied dc magnetic field at millikelvin temperatures. The photon modes are confined mainly to the sphere and exhibited large mode filling factors in comparison to previous experiments, allowing ultrastrong coupling with the magnon spin-wave resonances. The largest observed coupling between photons and magnons is 2g/2π=7.11 GHz for a 15.5-GHz mode, corresponding to a cooperativity of C=1.51±0.47×107. Complex modifications, beyond a simple multioscillator model, of the photon mode frequencies were observed between 0 and 0.1 T. Between 0.4 and 1 T, degenerate resonant photon modes were observed to interact with magnon spin-wave resonances with different coupling strengths, indicating time-reversal symmetry breaking due to the gyrotropic permeability of YIG. Bare dielectric resonator mode frequencies were determined by detuning magnon modes to significantly higher frequencies with strong magnetic fields. By comparing measured mode frequencies at 7 T with finite element modeling, a bare dielectric permittivity of 15.96±0.02 of the YIG crystal has been determined at about 20 mK.

9 July 2013 in Nature Communications
Verified
Journal Article
Open access
PDF file
RTR. Le Targat
R. Le Targat
LLL. Lorini
L. Lorini
YCY. Le Coq
Y. Le Coq
MZM. Zawada
M. Zawada
JGJ. Guéna
J. Guéna
JLJ. Lodewyck
J. Lodewyck
Progress in realizing the SI second had multiple technological impacts and enabled further constraint of theoretical models in fundamental physics. Caesium microwave fountains, realizing best the second according to its current definition with a relative uncertainty of 2–4 × 10−16, have already been overtaken by atomic clocks referenced to an optical transition, which are both more stable and more accurate. Here we present an important step in the direction of a possible new definition of the second. Our system of five clocks connects with an unprecedented consistency the optical and the microwave worlds. For the first time, two state-of-the-art strontium optical lattice clocks are proven to agree within their accuracy budget, with a total uncertainty of 1.5 × 10−16. Their comparison with three independent caesium fountains shows a degree of accuracy now only limited by the best realizations of the microwave-defined second, at the level of 3.1 × 10−16.