Chengxiang Wang

Dr. Chengxiang Wang

orcid

Research Focus & Metrics

Academic Career Length

4Years (2023-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
1 July 2025 in Inverse Problems
Verified
Journal Article
Closed access
CWChengxiang Wang
Chengxiang Wang
ZBZhouyu Bi
Zhouyu Bi
BLBaodong Liu
Baodong Liu
JQJiemin Que
Jiemin Que
LZLingli Zhang
Lingli Zhang
WYWei Yu
Wei Yu
Computed tomography is a highly effective inspection methodology for non-destructive testing, however, it faces challenges with objects that have a significant aspect ratio. In such scenarios, computed laminography (CL) serves as a viable alternative. The unique geometric configuration of cone-beam rotary CL makes the classical FDK reconstruction algorithm unsuitable. To address this inverse problem, we proposed an approximate analytical reconstruction method inspired by the core idea of the FDK algorithm. Firstly, we addressed the cone-beam rotary CL reconstruction problem by approximating it as a series of fan-beam reconstruction tasks, and deriving the geometric relationships between the original coordinate system and the fan-beam coordinates. Secondly, the fan-beam reconstruction formula within the fan-beam coordinate system is derived. Finally, disregarding the fact that the projection data come from different planes based on the idea of the Feldkamp–Davis–Kress algorithm, an approximate analytical reconstruction algorithm is derived based on the geometric relationships between the original coordinate system and the detector coordinates. The effectiveness of our method is demonstrated through simulations and real data experiments. The results demonstrate that the proposed method mitigates the superimposition artifacts and enhances the fine structural details to a certain extent compared to the CL-filtered backprojection method, while preserving the object boundaries.

24 April 2024 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
CWChengxiang Wang
Chengxiang Wang
YXYuanmei Xia
Yuanmei Xia
JWJiaxi Wang
Jiaxi Wang
ZQZhao Ke Quan
Zhao Ke Quan
WPWei Peng
Wei Peng
WYWei Yu
Wei Yu
Objective. Limited-angle x-ray computed tomography (CT) is a typical ill-posed inverse problem, leading to artifacts in the reconstructed image due to the incomplete projection data. Most iteration CT reconstruction methods involve optimization for a single object. This paper explores a multi-objective optimization model and an interactive method based on multi-objective optimization to suppress the artifacts of limited-angle CT. Approach. The model includes two objective functions on the dual domain within the data consistency constraint. In the interactive method, the structural similarity index measure (SSIM) is regarded as the value function of the decision maker (DM) firstly. Secondly, the DM arranges the objective functions of the multi-objective optimization model to be optimized according to their absolute importance. Finally, the SSIM and the simulated annealing (SA) method help the DM choose the desirable reconstruction image by improving the SSIM value during the iteration process. Main results. Simulation and real data experiments demonstrate that the artifacts can be suppressed by the proposed method, and the results were superior to those reconstructed by the other three reconstruction methods in preserving the edge structure of the image. Significance. The proposed interactive method based on multi-objective optimization shows some potential advantages over classical single object optimization methods.

3 July 2025 in Physics in Medicine & Biology
Verified
Journal Article
Closed access
YHYu He
Yu He
XLXinwei Luo
Xinwei Luo
CWChengxiang Wang
Chengxiang Wang
WYWei Yu
Wei Yu
Objective. low-dose computed tomography (LDCT) images suffer from severe noise due to reduced radiation exposure. Most existing deep learning-based denoising methods require supervised learning with paired training data that is difficult to obtain. To address this limitation, we aim to develop a denoising method that does not rely on paired normal-dose computed tomography data. Approach. we propose a self-supervised denoising method based on guided image filtering (GIF) that requires only LDCT images for training. The method first applies GIF to generate pseudo-labels from LDCT images, enabling the network to learn noise distributions between inputs and pseudo-labels for denoising, without paired data. Then, an attention gate (AG) mechanism is embedded in the decoder stage of a residual network to further enhance denoising performance. Main results. experimental results demonstrate that the proposed method achieves superior performance compared to state-of-the-art unsupervised denoising networks, transformer-based denoising model and post-processing methods, in terms of both visual quality and quantitative metrics. Furthermore, ablation studies are conducted to analyze the impact of different attention mechanisms and the number of AG mechanisms, showing that the proposed network architecture achieves optimal performance. Significance. this work leverages self-supervised learning with GIF to generate pseudo-labels, enabling LDCT denoising without paired data. The embedded AG mechanism, supported by detailed ablation analysis, further enhances denoising performance by improving feature focus and structural preservation.

30 January 2024 in Journal of Inverse and Ill-posed Problems
Verified
Journal Article
Closed access
HYHai Yin
Hai Yin
XLXianyun Li
Xianyun Li
ZLZhi Liu
Zhi Liu
WPWei Peng
Wei Peng
CWChengxiang Wang
Chengxiang Wang
WYWei Yu
Wei Yu
In X-ray CT imaging, there are some cases where the obtained CT images have serious ring artifacts and noise, and these degraded CT images seriously affect the quality of clinical diagnosis. Thus, developing an effective method that can simultaneously suppress ring artifacts and noise is of great importance. Total variation (TV) is a famous prior regularization for image denoising in the image processing field, however, for degraded CT images, it can suppress the noise but fail to reduce the ring artifacts. To address this issue, the L 0 smoothing filter is incorporated with TV prior for CT ring artifacts and noise removal problem where the problem is transformed into several optimization sub-problems which are iteratively solved. The experiments demonstrate that the ring artifacts and noise presented in the CT image can be effectively suppressed by the proposed method and meanwhile the detailed features such as edge structure can be well preserved. As the superiority of TV and L 0 smoothing filters are fully utilized, the performance of the proposed method is better than the existing methods such as the TV-based method and L 0 -based method.

14 September 2026 in Photonics
Verified
Journal Article
Open access
PDF file
ZBZhouyu Bi
Zhouyu Bi
CWChengxiang Wang
Chengxiang Wang
WYWei Yu
Wei Yu
QWQuan Wen
Quan Wen
WSWei Shang
Wei Shang
X-ray computed tomography (CT) is widely used in non-destructive testing; however, it exhibits inherent limitations when scanning objects with a large aspect ratio. Computed laminography (CL) provides an alternative solution; nevertheless, due to its distinctive scanning geometry, analytical CL reconstruction methods, such as the filtered back projection (FBP) algorithm, are prone to laminographic and superposition artifacts, thereby degrading image quality. To address this issue, a perspective transformation-based data conversion method (PT-CL-FDK) for cone-beam CL is proposed. Firstly, a virtual detector is introduced, and the perspective transformation relationship between the real and virtual detectors is derived. Secondly, the acquired CL projection data are transformed onto the virtual detector. Finally, the converted projection data are reconstructed using a CL-FDK algorithm. Simulation and real printed circuit board (PCB) experimental results demonstrate that, compared with CL-FBP, the proposed method effectively suppresses superposition artifacts and preserves object boundaries, while significantly enhancing the contrast and resolution of void defects in PCBs.

10 November 2026 in Measurement Science and Technology
Verified
Journal Article
Closed access
CWChengxiang Wang
Chengxiang Wang
WYWei Yu
Wei Yu
BLBaodong Liu
Baodong Liu
Non-destructive evaluation of high-aspect-ratio electronic components, such as insulated gate bipolar transistors and printed circuit boards, demands reconstruction methods that combine measurement accuracy with high throughput. Cone-beam rotary computed laminography (CL) is usually implemented by tilting the source–detector assembly or the object within a conventional CT geometry. Though mechanically simple, this tilting breaks circular symmetry, so analytic reconstruction suffers from inter-slice aliasing and structural distortion. The CL-filtered backprojection and CL-Feldkamp–Davis–Kress methods directly adopt the ramp filter and weighting factor used in cone-beam CT, without a detailed justification or derivation for why they remain valid in this geometry. This paper derives a frequency-domain pseudoinverse filter over the measurable frequency support from the point spread function (PSF) of the CL geometry. To avoid the prohibitive cost of direct three-dimensional image-domain filtering, we reformulate the operation in the 2D projection domain and handle the resulting nonlinear coordinate mapping via a principled approximation. The key theoretical result is that, under practical assumptions, this approximated filter collapses analytically to a scaled ramp filter, thereby providing the first theoretical justification for the ramp filter and clarifying precisely when it fails. The improved image quality, however, stems from two further components: the projection weighting and a complementary 2D spectral filter that corrects the residual approximation errors. Experiments confirm that the proposed CL-PSF method consistently outperforms other analytic algorithms in correcting structural distortion. The theoretical derivation further motivates three practical strategies for suppressing inter-slice aliasing: restricting the valid reconstruction thickness, restricting the reconstruction volume to a compact region of interest, and adopting a detector with a smaller in-plane size. All three strategies are validated experimentally. The proposed method thus offers a fast and well-founded reconstruction approach for quantitative industrial inspection.