The physiological integrity of spiral ganglion neurons is presumed to influence cochlear implant (CI) outcomes, but it is difficult to measure neural health in CI listeners. Modeling data suggest that, when peripheral processes have degenerated, anodic stimulation may be a more effective neural stimulus than cathodic stimulation. The primary goal of the present study was to evaluate the emerging theory that polarity sensitivity reflects neural health in CI listeners. An ideal in vivo estimate of neural integrity should vary independently of other factors known to influence the CI electrode-neuron interface, such as electrode position and tissue impedances. Thus, the present analyses quantified the relationships between polarity sensitivity and (1) electrode position estimated via computed tomography imaging, (2) intracochlear resistance estimated via electrical field imaging, and (3) focused (steered quadrupolar) behavioral thresholds, which are believed to reflect a combination of local neural health, electrode position, and intracochlear resistance. Eleven adults with Advanced Bionics devices participated. To estimate polarity sensitivity, electrode-specific behavioral thresholds in response to monopolar, triphasic pulses where the central high-amplitude phase was either anodic (CAC) or cathodic (ACA) were measured. The polarity effect was defined as the difference in threshold response to the ACA compared to the CAC stimulus. Results indicated that the polarity effect was not related to electrode-to-modiolus distance, electrode scalar location, or intracochlear resistance. Large, positive polarity effects, which may indicate SGN degeneration, were associated with relatively high focused behavioral thresholds. The polarity effect explained a significant portion of the variation in focused thresholds, even after controlling for electrode position and intracochlear resistance. Overall, these results provide support for the theory that the polarity effect may reflect neural integrity in CI listeners. Evidence from this study supports further investigation into the use of polarity sensitivity for optimizing individual CI programming parameters.
25 March 2019 in Journal of the Association for Research in Otolaryngology
Cochlear implant (CI) programming is similar for all CI users despite limited understanding of the electrode-neuron interface (ENI). The ENI refers to the ability of each CI electrode to effectively stimulate target auditory neurons and is influenced by electrode position, neural health, cochlear geometry, and bone and tissue growth in the cochlea. Hearing history likely affects these variables, suggesting that the efficacy of each channel of stimulation differs between children who were implanted at young ages and adults who lost hearing and received a CI later in life. This study examined whether ENI quality differed between early-implanted children and late-implanted adults. Auditory detection thresholds and most comfortable levels (MCLs) were obtained with monopolar and focused electrode configurations. Channel-to-channel variability and dynamic range were calculated for both types of stimulation. Electrical field imaging data were also acquired to estimate levels of intracochlear resistance. Children exhibited lower average auditory perception thresholds and MCLs compared with adults, particularly with focused stimulation. However, neither dynamic range nor channel-to-channel threshold variability differed between groups, suggesting that children’s range of perceptible current was shifted downward. Children also demonstrated increased intracochlear resistance levels relative to the adult group, possibly reflecting greater ossification or tissue growth after CI surgery. These results illustrate physical and perceptual differences related to the ENI of early-implanted children compared with late-implanted adults. Evidence from this study demonstrates a need for further investigation of the ENI in CI users with varying hearing histories.
Cochlear implant programming typically involves measuring electrode impedance, selecting a speech processing strategy and fitting the dynamic range of electrical stimulation. This study retrospectively analyzed a clinical dataset of adult cochlear implant recipients to understand how these variables relate to speech recognition. Data from 425 implanted post-lingually deafened ears with Advanced Bionics devices were analyzed. A linear mixed-effects model was used to infer how impedance, programming and patient factors were associated with monosyllabic word recognition scores measured in quiet. Additional analyses were conducted on subsets of data to examine the role of speech processing strategy on scores, and the time taken for the scores of unilaterally implanted patients to plateau. Variation in basal impedance was negatively associated with word score, suggesting importance in evaluating the profile of impedance. While there were small, negative bivariate correlations between programming level metrics and word scores, these relationships were not clearly supported by the model that accounted for other factors. Age at implantation was negatively associated with word score, and duration of implant experience was positively associated with word score, which could help to inform candidature and guide expectations. Electrode array type was also associated with word score. Word scores measured with traditional continuous interleaved sampling and current steering speech processing strategies were similar. The word scores of unilaterally implanted patients largely plateaued within 6-months of activation. However, there was individual variation which was not related to initially measured impedance and programming levels.
24 February 2022 in Journal of Speech, Language, and Hearing Research
Purpose: This review article provides a theoretical overview of the development of spectral resolution in children with normal hearing (cNH) and in those who use cochlear implants (CIs), with an emphasis on methodological considerations. The aim was to identify key directions for future research on spectral resolution development in children with CIs. Method: A comprehensive literature review was conducted to summarize and synthesize previously published behavioral research on spectral resolution development in normal and impaired auditory systems. Conclusions: In cNH, performance on spectral resolution tasks continues to improve through the teenage years and is likely driven by gradual maturation of across-channel intensity resolution. A small but growing body of evidence from children with CIs suggests a more complex relationship between spectral resolution development, patient demographics, and the quality of the CI electrode–neuron interface. Future research should aim to distinguish between the effects of patient-specific variables and the underlying physiology on spectral resolution abilities in children of all ages who are hard of hearing and use auditory prostheses.
Speech recognition outcomes are highly variable among pediatric and adult cochlear implant (CI) listeners. Although there is some evidence that the quality of the electrode-neuron interface (ENI) contributes to this large variability in auditory perception, its relationship with speech outcomes is not well understood. Single-channel auditory detection thresholds measured in response to focused electrical fields (i.e., focused thresholds) are sensitive to properties of ENI quality, including electrode-neuron distance, intracochlear resistance, and neural health. In the present study, focused thresholds and speech perception abilities were assessed in 15 children and 21 adult CI listeners. Focused thresholds were measured for all active electrodes using a fast sweep procedure. Speech perception performance was evaluated by assessing listeners’ ability to identify vowels presented in /h-vowel-d/ context. Consistent with prior literature, focused thresholds were lower for children than for adults, but vowel identification did not differ significantly across age groups. Higher across-array average focused thresholds, which may indicate a relatively poor ENI quality, were associated with poorer vowel identification scores in both children and adults. Adult CI listeners with longer durations of deafness had higher focused thresholds. Findings from this study demonstrate that poor-quality ENIs may contribute to reduced speech outcomes for pediatric and adult CI listeners. Estimates of ENI quality (e.g., focused thresholds) may assist in developing customized programming interventions that serve to improve the transmission of spectral cues that are important in vowel identification.