Reliable quantification of ammonia (NH 3 ) surface–atmosphere exchange remains challenging due to the compound's reactivity, inlet interactions, and the sensitivity of gradient-based flux estimates to instrumental response characteristics. We present the field evaluation and methodological assessment of a quantum-cascade-laser (QCL) based photoacoustic (PA) aerodynamic gradient system for half-hourly NH 3 flux measurements under agricultural conditions. The campaign covered a 54 d post-fertilization period under predominantly dry soil conditions, including the transition from bare soil to a developing winter rapeseed canopy. Instrumental performance was assessed through co-located inlet comparison experiments, yielding a random uncertainty of ±2 ppb (1 σ ) and demonstrating negligible systematic bias between sampling channels. The system operated continuously under field conditions with active thermal stabilization and humidity management. Fluxes were calculated using Monin–Obukhov similarity theory (MOST) across an ensemble of universal stability functions to evaluate methodological sensitivity. Sensitivity analysis indicated that variability attributable solely to stability-function selection remained small relative to observed diurnal flux amplitudes. The mean NH 3 loss over the investigated period was 1.85 nmol m −2 s −1 , corresponding to a cumulative loss of 1.21 kg N ha −1 or 4.0 % of the applied fertilizer nitrogen. Based on instrumental uncertainty (±2 ppb) and literature-reported uncertainty ranges of MOST-based aerodynamic gradient flux calculations, the overall uncertainty is estimated to be approximately ±25 %, corresponding to ±0.30 kg N ha −1 . A pronounced diurnal asymmetry was observed, with daytime emissions approximately 1 order of magnitude higher than nighttime values, reflecting strong coupling between turbulent exchange and radiation-driven surface processes. Complementary machine-learning analysis indicated that incorporating short-term temporal memory substantially improved the representation of NH 3 flux dynamics and revealed distinct daytime and nighttime exchange regimes. The combined QCL–photoacoustic gradient system demonstrated robust field performance and low instrumental bias, supporting its applicability for long-term field-scale studies of agricultural NH 3 exchange under post-fertilization conditions.
Reliable quantification of ammonia (NH3) surface–atmosphere exchange remains challenging due to the compound’s reactivity, inlet interactions, and the sensitivity of gradient-based flux estimates to instrumental response characteristics. We present the field evaluation and methodological assessment of a quantum-cascade- laser (QCL) based photoacoustic (PA) aerodynamic gradient system for half-hourly NH3 flux measurements under agricultural conditions. The campaign covered a 54-day post-fertilization period under predominantly dry soil conditions, including the transition from bare soil to a developing winter rapeseed canopy. Instrumental performance was assessed through co-located inlet comparison experiments, yielding a random uncertainty of ±2 ppb (1σ) and demonstrating negligible systematic bias between sampling channels. The system operated continuously under field conditions with active thermal stabilization and humidity management. Fluxes were calculated using Monin-Obukhov similarity theory (MOST) across an ensemble of universal stability functions to evaluate methodological sensitivity. Sensitivity analysis indicated that variability attributable solely to stability-function selection remained small relative to observed diurnal flux amplitudes. Mean NH3 emission during the investigated period was 1.85 nmol m–2 s–1, corresponding to 1.21 kg N ha–1 or 4.0 % of the applied fertilizer nitrogen. A pronounced diurnal asymmetry was observed, with daytime emissions approximately one order of magnitude higher than nighttime values, reflecting strong coupling between turbulent exchange and radiation-driven surface processes. Complementary machine-learning analysis indicated that incorporating short-term temporal memory substantially improved the representation of NH3 flux dynamics and revealed distinct daytime and nighttime exchange regimes. The combined QCL–photoacoustic gradient system demonstrated robust field performance and low instrumental bias, supporting its applicability for long-term field-scale studies of reactive trace gas exchange.
Soil ammonia (NH3) emissions are a major pathway for reactive nitrogen loss, but their spatial variability is difficult to explain using equilibrium-based approaches alone. This study evaluated whether machine learning can improve the interpretation of NH3 flux by identifying informative soil predictors. NH3 flux, soil temperature and volumetric water content (approximately 0–6 cm) were measured at 20 sampling points on bare agricultural soil, while NH4+, NO3−, total nitrogen, humus content and pH were determined at three soil depths. Five regression models were evaluated using leave-one-out cross-validation. Pairwise correlations showed that no single measured variable exhibited a dominant linear relationship with NH3 flux. Nevertheless, Random Forest achieved the best cross-validated performance (R2 = 0.418), suggesting that the observed spatial variability was better represented by multivariate and potentially nonlinear relationships among soil properties than by individual linear associations. Partial Least Squares Regression provided complementary information on the multivariate soil gradients. Within the Random Forest model, NO3− concentration at 10–20 cm and near-surface soil moisture had the highest permutation importance. These findings indicate that small-scale spatial variation in NH3 flux was associated with the combined statistical information contained in several soil properties rather than with a single dominant linear predictor. The importance of NO3− represents a dataset-specific statistical association and should not be interpreted as evidence of direct causal control or nitrification intensity.
Reliable quantification of ammonia (NH3) surface–atmosphere exchange remains challenging due to the compound’s reactivity, inlet interactions, and the sensitivity of gradient-based flux estimates to instrumental response characteristics. We present the field evaluation and methodological assessment of a quantum-cascade- laser (QCL) based photoacoustic (PA) aerodynamic gradient system for half-hourly NH3 flux measurements under agricultural conditions. The campaign covered a 54-day post-fertilization period under predominantly dry soil conditions, including the transition from bare soil to a developing winter rapeseed canopy. Instrumental performance was assessed through co-located inlet comparison experiments, yielding a random uncertainty of ±2 ppb (1σ) and demonstrating negligible systematic bias between sampling channels. The system operated continuously under field conditions with active thermal stabilization and humidity management. Fluxes were calculated using Monin-Obukhov similarity theory (MOST) across an ensemble of universal stability functions to evaluate methodological sensitivity. Sensitivity analysis indicated that variability attributable solely to stability-function selection remained small relative to observed diurnal flux amplitudes. Mean NH3 emission during the investigated period was 1.85 nmol m–2 s–1, corresponding to 1.21 kg N ha–1 or 4.0 % of the applied fertilizer nitrogen. A pronounced diurnal asymmetry was observed, with daytime emissions approximately one order of magnitude higher than nighttime values, reflecting strong coupling between turbulent exchange and radiation-driven surface processes. Complementary machine-learning analysis indicated that incorporating short-term temporal memory substantially improved the representation of NH3 flux dynamics and revealed distinct daytime and nighttime exchange regimes. The combined QCL–photoacoustic gradient system demonstrated robust field performance and low instrumental bias, supporting its applicability for long-term field-scale studies of reactive trace gas exchange.