Yiming Wang

Ms. Yiming Wang


Research Focus & Metrics

Academic Career Length

1Year (2026-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
4 August 2026 in Preprints.org
Verified
Preprint
Open access
PDF file
YWYiming Wang
Yiming Wang
FDFenggang Dai
Fenggang Dai
HYHongchao Yao
Hongchao Yao
AWAihua Wei
Aihua Wei
RWRui Wang
Rui Wang
WZWei Zhang
Wei Zhang
Determining the recharge sources of adjacent old-working water outlets and their hydraulic connections is essential for zoned pollution control in closed coal mines. This study examined two outlets, S1 and S2, 174 m apart in the Chunjingwa closed coal mine area, Shanxi Province, China. Discharge dynamics, hydrochemistry, hydrogen–oxygen stable isotopes, and a goaf pumping test were combined. S2 showed 9.7 times the discharge variation of S1 and responded more rapidly to rainfall. Most contamination indicators had higher median exceedance levels at S2; isotopically, S1 overlapped with goaf boreholes ZK2 and ZK3, whereas S2 was heavier. During pumping, S1 discharge fell by about 91% and partially recovered, whereas S2 remained stable. The evidence identifies two distinct recharge–discharge systems on opposite sides of F2 and indicates limited cross-fault hydraulic communication at the tested scale and duration. F2 is interpreted as a structural divide, not a uniformly impermeable fault. S1 is regulated mainly by goaf-water storage to the south, whereas S2 is dominated by shallow-catchment, rapid-infiltration recharge to the north. The framework provides a practical alternative to artificial tracer tests for outlet-scale source identification and zoned remediation.

8 September 2026 in Water
Verified
Journal Article
Open access
PDF file
YWYiming Wang
Yiming Wang
FDFenggang Dai
Fenggang Dai
HYHongchao Yao
Hongchao Yao
AWAihua Wei
Aihua Wei
RWRui Wang
Rui Wang
WZWei Zhang
Wei Zhang
Determining the recharge sources of adjacent old-working water outlets and their hydraulic connections is essential for zoned pollution control in closed coal mines. This study examined two outlets, S1 and S2, 174 m apart in the Chunjingwa closed coal mine area, Shanxi Province, China. Discharge dynamics, hydrochemistry, hydrogen–oxygen stable isotopes, and a goaf pumping test were combined. During natural monitoring, discharges at S1 and S2 ranged from 1.172–1.958 and 1.012–8.630 m3/h, respectively, with the variation at S2 (7.618 m3/h) being 9.7 times that at S1 (0.786 m3/h). Most contamination indicators had higher median exceedance levels at S2; for SO42−, the median was 14.6 at S2 versus 8.4 at S1. Isotopically, S1 overlapped with ZK2 and ZK3, whereas S2 was distinct. During the 27-day pumping test, S1 discharge fell by about 91%, whereas S2 showed no clear response. The evidence identifies two distinct recharge–discharge systems on opposite sides of F2 at the tested scale. F2 is interpreted as a structural divide, not a uniformly impermeable fault. S1 is regulated mainly by goaf-water storage to the south, whereas S2 is dominated by shallow-catchment, rapid-infiltration recharge to the north. The framework provides a practical alternative to artificial tracer tests for outlet-scale source identification and zoned remediation.