Paweł Janik

Dr. Paweł Janik

orcid

Research Focus & Metrics

Academic Career Length

6Years (2021-Present)

(Calculated once Scilit publication data is synced: current year − year of first publication + 1)

Representative Publications

View All Publications
9 June 2021 in Applied Sciences
Verified
Journal Article
Open access
PDF file
PJPaweł Janik
Paweł Janik
MZMaciej Zawistowski
Maciej Zawistowski
RFRadosław Fellner
Radosław Fellner
GZGrzegorz Zawistowski
Grzegorz Zawistowski
Worldwide, there is a significant increase in the use of unmanned aerial vehicles (UAVs) by emergency services. They offer a lot of possibilities during rescue operations. Such a wide application for various purposes and environments causes many threats related to their use. To minimize the risks associated with conducting air operations with UAVs, the application of the SORA (Specific Operations Risk Assessment) methodology will be important. Due to its level of detail, it is a methodology adapted to civilian use. In this article, the authors’ team will try to develop guidelines and directions for adapting SORA to the requirements of the operational work of emergency services. Thus, the following article aims to present the most important risks related to conducting operations with the use of UAVs by first responders (FRs), and to show the sample risk analysis performed for this type of operation on the example of the ASSISTANCE project. The paper describes, on the one hand, possibilities offered by UAVs in crisis or disaster management and step-by-step Specific Operations Risk Assessment (SORA), and on the other hand, presents possible threats, consequences and methods of their mitigation during FR missions.

27 May 2022 in Energies
Verified
Journal Article
Open access
PDF file
PKPiotr Kaczmarzyk
Piotr Kaczmarzyk
Łukasz WargułaŁukasz Warguła
Łukasz Warguła
PJPaweł Janik
Paweł Janik
PKPiotr Krawiec
Piotr Krawiec
Since there are no legally defined testing requirements for mobile positive pressure fans, they may be tested based on methods that do not correspond to their actual operating conditions. Adequate assessment of the technical and operating conditions for this type of equipment is particularly important for equipment used in rescue operations. Such units should be characterized by efficient and reliable operation. This article investigates the influence of measurement methods of the volumetric airflow rate on the performance of a power unit. The article shows that the applied measurement method, whether it is PN-EN ISO 5801 (test conditions in a pipe duct—Method A) or other methods, i.e., ANSI/AMCA 240-15 and testing of the characteristics of the velocity profile (tests in open flow—Method B), can cause differences in the power demand of fans of from 3.2% to 4.5%. The differences in the requirements of propulsion power translate into fuel consumption and emissions of harmful exhaust gases generated by the combustion drive units (4 kW). It was also observed that fans with conventional impellers (W1) show a lower power demand when applying Method B (open flow) tests, while fans with turbo impellers (W2) show a lower power demand when Method A (duct) tests are applied. Comparative analysis of the parameters of the drive unit in the test group of fans without taking into account the measurement method can cause errors of up to about 7.7%, 6.4%, and 2.4% for the power, torque, and speed, respectively.

1 January 2022 in Safety and Fire Technology
Verified
Journal Article
Open access
PKPiotr Kaczmarzyk
Piotr Kaczmarzyk
PJPaweł Janik
Paweł Janik
WKWojciech Klapsa
Wojciech Klapsa
GBGrzegorz Bugaj
Grzegorz Bugaj

5 May 2023 in Applied Sciences
Verified
Journal Article
Open access
PDF file
PKPiotr Kaczmarzyk
Piotr Kaczmarzyk
PJPaweł Janik
Paweł Janik
DMDaniel Maloziec
Daniel Maloziec
WKWojciech Klapsa
Wojciech Klapsa
Łukasz WargułaŁukasz Warguła
Łukasz Warguła
During rescue operations, one of the important parameters determining the effectiveness of the implementation of tactical mechanical ventilation is the selection of the appropriate size of the outlet opening. The objective of this article is to determine the effect of the size of the discharge opening area (0.24–1.2 m2) and other factors on the obtained flow parameters (flow velocity, volumetric flow rate and static pressure value) generated by the two tested positive pressure ventilators. The volumetric flow rate was determined by measuring the flow velocity at appropriately selected measurement points. Two ventilator units were tested (one was the conventional type, while two were turbo). During the tests, the fans generated a flow of 4624.17 m3/h to 14,020.92 m3/h (the first—conventional type) and 4884.66 m3/h to 15,656.33 m3/h (the second—turbo type). The analysis carried out in the article can be used as a guideline for designers of buildings, with particular emphasis on cases in which the staircase is not directly adjacent to the façade wall (an escape route built into the axis of the building).


11 May 2022 in Materials
Verified
Journal Article
Open access
PDF file
Piotr IzakPiotr Izak
Piotr Izak
MBMateusz Biel
Mateusz Biel
JMJoanna Mastalska-Popławska
Joanna Mastalska-Popławska
PJPaweł Janik
Paweł Janik
PMPiotr Mortka
Piotr Mortka
PLPiotr Lesiak
Piotr Lesiak
This article analyzes the possibility of the modification of BC powder (a mixture of sodium bicarbonate and calcium carbonate) with magnesium hydroxide (Mg(OH)2). Extinguishing efficiency as well as the influence of this additive on other physicochemical properties were determined by performing a 13B fire test, rheological measurements of the powders, thermal tests (thermogravimetry (TG) and differential scanning calorimetry (DSC) in combination with quadrupole mass spectrometry (QMS)) and microscopic observations of the powders’ surface (scanning electron microscope (SEM) with energy dispersive X-ray analysis (EDS)). It was found that the increase of the Mg(OH)2 content causes deterioration of the rheological properties by increasing the slope angle of the flow curve in relation to the normal stress (the tangent of the flow curve slope varying from 0.258 for 5% of Mg(OH)2 up to 0.330 for 20% of Mg(OH)2). However, at the same time, the increased content of Mg(OH)2 increases the total energy of the chemical decomposition reaction (from −47.27 J/g for 5% of Mg(OH)2 up to −213.6 J/g for 20% of Mg(OH)2) resulting in the desirable higher level of heat removal from the fire. The initial extinguishing effect of the fire becomes more effective as the hydroxide content increases (within the first 2 s), but at a later stage (from t = 63 s), the temperature is no longer sufficient (it is below 350 °C) for thermal decomposition of Mg(OH)2. As such, the optimal content of Mg(OH)2 is 10–15%. The obtained results allowed for the assessment of the impact of individual powder components on its extinguishing effect and will contribute to the development of science in the field of developing new types of extinguishing powders.