Carbon dioxide (CO2) rebreathing has been recognised as a concern regarding respirator use and is related to symptoms of discomfort, fatigue, dizziness, headache, muscular weakness and drowsiness. Previous investigations are limited by small sample size and have not evaluated the relationship between CO2 inhalation and phonic respiration (breathing during speech) in respiratory protective devices (RPDs). A total of 40 workers trained in the use of RPDs performed a graded exercise test on a cycle ergonometer that increased in workload every 5 min. During the third minute of each stage, participants read aloud a prepared text. Measures of mixed expired CO2 (PECO2), mixed inspired CO2 (PICO2) and respiration were monitored. The results showed that phonic respiration and low work rates contributed to significantly higher levels of CO2 rebreathing. Aiming to reduce CO2 exposure may result in improved wear time of RPDs. It is recommended that these findings be incorporated in technical specifications regarding human factors for RPDs. Practitioner Summary: Carbon dioxide (CO2) rebreathing in respiratory protective devices (RPDs) has been highlighted as a key concern regarding respirator use. However, the problem is relatively under researched. This paper presents novel findings on the impact of phonic respiration (breathing during speech) and CO2 concentrations in RPDs.
24 August 2017 in Journal of Occupational and Environmental Hygiene
Biomedical researchers use of inhalational anesthetics has increased in recent years. Use of isoflurane as an inhalational anesthetic may result in human exposure to waste anesthetic gas. Potential health effects from exposure include genotoxic and hepatotoxic effects with some evidence of teratogenic and reproductive effects. Research suggests that exposure to waste anesthetic gas within human hospital settings has improved substantially but exposures to biomedical researchers and veterinarians still requires improvement. A number of biomedical research facilities are located at The University of Queensland, Australia, where researchers and animal handlers are potentially exposed to waste isoflurane gas. There is limited published data on the exposures received by biomedical researchers performing routine procedures. This project aimed to assess isoflurane exposure received during routine rodent anesthetic protocols performed at the university. Atmospheric concentrations of isoflurane were assessed via two methods—personal active gas sampling using sorbent tubes and direct readings using infrared spectroscopy. Total procedure and isoflurane exposure times ranged from 135–268 min. Personal sorbent tube sampling detected isoflurane levels from below detectable limits (<0.01 ppm) to a Time Weighted Average for the task (TWA-Task) of 6.20 ppm (0.73 ± 9.13). Participants were not exposed to isoflurane outside of the sampling period during the remainder of the workday. TWA-8 hr adjusted levels ranged from below the limit of detection to 1.76 ppm isoflurane (0.69 ppm ± 0.61 ppm). The infrared spectroscopy readings taken in the breathing zone of participants ranged from 0.1–68 ppm. Results indicate that if adequately controlled through good room ventilation, effective active gas scavenging and well constructed anesthetic equipment, waste anesthetic exposures are minimal. However, where industry standards are not met exposures may occur, including some high peak exposures.
24 March 2025 in IEEE Transactions on Artificial Intelligence
Point clouds captured from 3D scanners are often sparse and incomplete due to occlusions, limited viewpoints, and sensor constraints. These limitations hinder applications in robotics, autonomous navigation, and augmented reality. Hence, point cloud completion is crucial for generating reliable 3D object representations. Existing methods often struggle to capture structural patterns effectively, which leads to low-quality reconstructions. To address these challenges, we propose Centroid Transformer (CenFormer), a novel transformer-based network for point cloud completion. CenFormer introduces two distinct types of centroids, namely Preserved and Dispersed, to facilitate fine-grained reconstruction. The proposed design includes three innovations: i) a Centroid Generation Block to aggregate features for preserved centroids, ii) a Centroid Dispersion Block to predict offsets for dispersed centroids, and iii) a Fine-grained Point Generation Block to refine local patterns around centroids. These components jointly enable the network to effectively capture local structural details and strategically target missing regions for fine-grained 3D shape reconstruction. Experiments on various benchmark datasets demonstrate that CenFormer significantly outperforms state-of-the-art methods in both visualization results and quantitative metrics.
Diesel engines have been a mainstay within many industries since the early 1900s. Exposure to diesel particulate matter (DPM) is a major issue in many industrial workplaces given the potential for serious health impacts to exposed workers; including the potential for lung cancer and adverse irritant and cardiovascular effects. Personal respiratory protective devices are an accepted safety measure to mitigate worker exposure against the potentially damaging health impacts of DPM. To be protective, they need to act as effective filters against carbon and other particulates. In Australia, the filtering efficiency of respiratory protective devices is determined by challenging test filter media with aerosolised sodium chloride to determine penetration at designated flow rates. The methodology outlined in AS/NZS1716 (Standards Australia International Ltd and Standards New Zealand 2012. Respiratory protective devices. Sydney/Wellington: SAI Global Limited/Standards New Zealand) does not account for the differences between characteristics of workplace contaminants like DPM and sodium chloride such as structure, composition, and particle size. This study examined filtering efficiency for three commonly used AS/NZS certified respirator filter models, challenging them with two types of diesel emissions; those from a diesel generator and a diesel engine. Penetration through the filter media of elemental carbon (EC), total carbon (TC), and total suspended particulate (TSP) was calculated. Results indicate that filtering efficiency assumed by P2 certification in Australia was achieved for two of the three respirator models for DPM generated using the small diesel generator, whilst when the larger diesel engine was used, filtering efficiency requirements were met for all three filter models. These results suggest that the testing methodology specified for certification of personal respiratory protective devices by Standards Australia may not ensure adequate protection for respirator users against DPM under all circumstances of diesel generated particles.
12 March 2026 in Annals of Work Exposures and Health
Introduction: Tunnel construction activities are associated with exposure to respirable crystalline silica (RCS), placing workers at risk of silicosis and lung cancer. Respiratory protective equipment (RPE) is frequently relied upon to supplement other control measures to reduce exposure. However, the practical effectiveness of RPE in preventing over-exposure can be compromised by a range of factors, reducing its expected level of protection. Objective: To identify and explore the factors that influence the practical effectiveness of RPE programs in tunnel construction environments. Methods: A retrospective analysis of exposure assessments between 2018 and 2024, prepared by occupational hygienists across multiple Australian tunnel construction projects, was performed. The focus was on instances where RPE was used but where RCS exposures were still judged by the occupational hygienist to have exceeded the occupational exposure limit (OEL) in place at the time. Contributing factors were identified and categorised. Results: Occupational hygienists identified six factors that impacted the practical effectiveness of RPE when RCS was measured above the OEL. The most common factor was that the RPE provided to the worker had an insufficient minimum protection factor to reduce exposure to levels below the OEL. Other factors included the absence of fit testing, the presence of facial hair, and intermittent or non-use of the RPE. In an average of 17% of cases where RCS exposure exceeded the OEL, occupational hygienists judged the RPE to be ineffective in adequately reducing exposure levels. Conclusion: The findings highlight organisational and individual factors that lead to a gap between theoretical performance and practical effectiveness of RPE programs. The reasons underlying these deficiencies, including why RPE was not worn, not correctly used, or why lower-grade protection was issued, remain unclear. Providing workers with higher levels of protection, such as powered air purifying respirators (PAPRs), would likely mitigate many of these challenges, which supports the growing shift toward PAPR adoption in the tunnelling sector.
29 May 2026 in Journal of Occupational and Environmental Hygiene
A functional understanding of human anatomy is fundamental for students studying health and medical sciences. Formalin, which is a formaldehyde-saturated solution, continues to be used for the preservation and disinfection of human specimens for teaching because other formalin substitutes are not readily available, practical, or preferred. The continued use of formalin exposes anatomy technicians who dissect human specimens to acute and chronic health effects, which has led to Australia's national government policy agency, Safe Work Australia, to pursue lower permitted airborne formaldehyde workplace exposure limits (WEL). During this study, 14 personal airborne samples were collected to calculate the geometric mean and 95th percentile of the formaldehyde 8-hr time-weighted average (8-hr TWA) and short-term exposure limit (STEL) for comparison to the current Australian WES and proposed Australian formaldehyde WELs. Three participants were recruited for the study and participated in formaldehyde air sampling and completed a questionnaire after each monitoring session to report formaldehyde exposure symptoms. The calculated 8-hr TWA and STEL geometric means were 1.1 and 1.4 ppm respectively, and the 95th percentile of both the 8-hr TWA and STEL exceeded the current Australian WES and proposed WELs. Questionnaire responses identified participants had experienced formaldehyde exposure symptoms related to itching eyes, inflamed eyes, headaches, and discomfort during dissection. Lower formaldehyde concentrations were identified during dissection in a dedicated dissection room where a partially effective dissection table with downdraft local exhaust ventilation and a laboratory fume hood were utilized, compared to teaching rooms with no local exhaust ventilation system. Formalin use continues to remain an occupational hazard for anatomy technicians who perform dissection, and careful attention is required toward implementing effective control measures such as substituting formalin with other suitable solutions, reducing formalin concentrations in embalming solutions, installing local exhaust ventilation systems, and using suitable personal protective equipment.